IEC 61443:1999+AMD1:2008 CSV

Current

Current

The latest, up-to-date edition.

Short-circuit temperature limits of electric cables with rated voltages above 30 kV (Um = 36 kV)

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

13-11-2008

€67.58
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Factors governing the application of the temperature limits
4 Maximum permissible short-circuit temperatures for cables with
  rated voltages above 30 kV (U[m] = 36 kV)

Gives guidance on the short-circuit maximum temperature limits of electric cables having rated voltages above 30 kV (Um = 36 kV) up to the voltage limits given in IEC 60141 and IEC 60840, with regard to the following:
- insulating materials;
- oversheath and bedding materials;
- conductor and metallic sheath materials and methods of connection.
The design of accessories and the influence of the installation conditions on the temperature limits are taken into consideration. The calculation of the permissible short-circuit current in the current-carrying components of the cable should be carried out in accordance with IEC 60949.

Committee
TC 20
DevelopmentNote
Stability Date: 2017. (09/2017)
DocumentType
Standard
Pages
20
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
UNE 211003-3:2001 Identical
NEN NPR IEC 61443 : 1999 AMD 1 2008 Identical

I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
04/301313 DC : DRAFT JAN 2004 IEC TR 61901 ED.1 - DEVELOPMENT TESTS RECOMMENDED ON CABLES WITH A LONGITUDINALLY APPLIED METAL FOIL
IEC 60840:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements
BS 7970:2005 Electric cables. Metallic wire and foil sheath constructions of power cables having XLPE insulation for rated voltages from 66kV (U<sub>m</sub> = 72.5 kV) to 132kV (U<sub>m</sub> = 145 kV)
04/300378 DC : DRAFT JAN 2004 IEC/TR 61901 - DEVELOPMENT TESTS RECOMMENDED ON CABLES WITH A LONGITUDINALLY APPLIED METAL FOIL
IEC TR 61901:2016 Tests recommended on cables with a longitudinally applied metal foil for rated voltages above 30 kV (U<sub>m</sub> = 36 kV) up to and including 500 kV (U<sub>m</sub> = 550 kV)

IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
IEC 60949:1988 Calculation of thermally permissible short-circuit currents, taking into account non-adiabatic heating effects