• IEC 61466-2:1998+AMD1:2002 CSV

    Current The latest, up-to-date edition.

    Composite string insulator units for overhead lines with a nominal voltage greater than 1 000 V - Part 2: Dimensional and electrical characteristics

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French

    Published date:  18-02-2002

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Mechanical and dimensional characteristics
    4 Electrical characteristics
    5 Designation
    6 Marking
    7 Tolerances
    8 Field control and arc protection devices
    Annex A (informative) Information on creepage distance
    Table 1 Designation and characteristics of composite
            insulators

    Abstract - (Show below) - (Hide below)

    Is applicable to composite string insulators with a specified mechanical load (SML) of 40 kN and 70 kN for a.c. overhead distribution lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz.It also applies to insulators of similar design used in substations or on electric traction lines.This consolidated version consists of the first edition (1998) and its amendment 1 (2002). Therefore, no need to order amendment inaddition to this publication.

    General Product Information - (Show below) - (Hide below)

    Committee TC 36
    Development Note Also numbered as BS EN 61466-2 (12/2002) Stability Date: 2019. (05/2018)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
    EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
    I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
    CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
    12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
    PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61466-1:2016 Composite string insulator units for overhead lines with a nominal voltage greater than 1 000 V - Part 1: Standard strength and end fittings
    IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
    HD 540.2 : 200S1 INSULATION COORDINATION - APPLICATION GUIDE
    EN 61466-1:2016 Composite string insulator units for overhead lines with a nominal voltage greater than 1000 V - Part 1: Standard strength classes and end fittings
    EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
    IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective