• VDE 0441-5 : 2002

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    COMPOSITE STRING INSULATOR UNITS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1 KV - DIMENSIONAL AND ELECTRICAL CHARACTERISTICS

    Available format(s): 

    Superseded date:  16-11-2022

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Verband Deutscher Elektrotechniker

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Anwendungsbereich
    2 Normative Verweisungen
    3 Mechanische Kenngrössen und Masse
    4 Elektrische Kenngrössen
    5 Bezeichnung
    6 Kennzeichnung
    7 Toleranzen
    Anhang A (informativ) Information zum Kriechweg
    Anhang ZA (normativ) Normative Verweisungen auf
              internationale Publikationen mit ihren
              entsprechenden europäischen Publikationen

    Abstract - (Show below) - (Hide below)

    Dieser Teil von IEC 61466 gilt für Verbund-Kettenisolatoren mit einer festgelegten mechanischen Kraft (SML) von 40 kN und 70 kN für Wechselstrom-Verteilungsfreileitungen mit einer Nennspannung über 1000 V und einer Frequenz bis 100 Hz. Er gilt auch für Isolatoren ähnlicher Konstruktion, die in Schaltanlagen oder für elektrische Fahrleitungen verwendet werden. Diese Norm gilt für Kettenisolatoren vom Verbundtyp mit Verbindungen nach IEC 61466-1. Diese Norm beschreibt festgelegte Werte für elektrische Kenngrössen und Masse von Verbund-Kettenisolatoren für Verteilungsfreileitungen mit einer höchsten Blitzstossspannung von 325 kV und einer festgelegten mechanischen Kraft (SML) von 40 kN und 70 kN. ANMERKUNG: Allgemeine Definitionen und Prüfverfahren sind in IEC 61109 angegeben.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes VDE 0441-103 (02/2003) DRAFT AMD 2 issued in April 2016. (05/2016)
    Document Type Standard
    Publisher Verband Deutscher Elektrotechniker
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    DIN EN 61466-1 : 2017 COR 1 2017 COMPOSITE STRING INSULATOR UNITS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - PART 1: STANDARD STRENGTH CLASSES AND END FITTINGS (IEC 61466-1:2016)
    IEC 61466-1:2016 Composite string insulator units for overhead lines with a nominal voltage greater than 1 000 V - Part 1: Standard strength and end fittings
    VDE 0441-4 : 1997 COR 1 2010 COMPOSITE STRING INSULATOR UNITS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1 KV - STANDARD STRENGTH CLASSES AND END FITTINGS
    VDE 0441-100 : 2009 INSULATORS FOR OVERHEAD LINES - COMPOSITE SUSPENSION AND TENSION INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1 000 V DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
    DIN VDE 0441-100 : DRAFT 1992 TESTS OF COMPOSITE INSULATORS FOR A.C. OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1000 V
    IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
    DIN EN 60071-1 : 2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
    IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    DIN EN 60071-2 : 1997 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective