IEC 61674:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Medical electrical equipment - Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
09-07-2024
English - French
29-11-2012
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terminology and definitions
4 General requirements
5 Limits of PERFORMANCE CHARACTERISTICS
6 LIMITS OF VARIATION for effects of INFLUENCE
QUANTITIES
7 Marking
8 ACCOMPANYING DOCUMENTS
Annex A (informative) - COMBINED STANDARD UNCERTAINTY
for dosimeter performance
Index of defined terms
IEC 61674:2012 specifies the performance and some related constructional requirements of diagnostic dosimeters intended for the measurement of air kerma, air kerma length product or air kerma rate, in photon radiation fields used in radiography, including mammography, radioscopy and computed tomography, for X-radiation with generating potentials not greater than 150 kV. This International Standard is applicable to the performance of dosimeters with vented ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging. The object of this standard is to establish requirements for a satisfactory level of performance for diagnostic dosimeters, and to standardize the methods for the determination of compliance with this level of performance. This standard is not concerned with the safety aspects of dosimeters. The diagnostic dosimeters covered by this standard are not intended for use in the patient environment and, therefore, the requirements for electrical safety applying to them are contained in IEC 61010-1. This second edition cancels and replaces the first edition and constitutes a technical revision.
Committee |
TC 62/SC 62C
|
DevelopmentNote |
Stability date: 2019. (12/2012)
|
DocumentType |
Standard
|
Pages |
74
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 61674:2003 | Identical |
NF EN 61674 : 2013 | Identical |
NEN EN IEC 61674 : 2013 | Identical |
PN EN 61674 : 2013 | Identical |
BS EN 61674:2013 | Identical |
CEI EN 61674 : 2014 | Identical |
EN 61674:2013 | Identical |
DIN EN 61674:2015-11 | Identical |
SN EN 61674:2013 | Identical |
UNE-EN 61674:2013 | Identical |
PNE-FprEN 61674 | Identical |
GOST R IEC 61674 : 2006 AMD 1 2011 | Identical |
SN EN 61674 : 1997 | Identical |
BS EN 62467-1:2015 | Medical electrical equipment. Dosimetric instruments as used in brachytherapy Instruments based on well-type ionization chambers |
17/30362279 DC : 0 | BS EN 61223-3-6 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-6: ACCEPTANCE AND CONSTANCY TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC TOMOSYNTHESIS MODE OF OPERATION OF MAMMOGRAPHIC X-RAY EQUIPMENT |
BS EN 61223-3-2:2008 | Evaluation and routine testing in medical imaging departments Acceptance tests. Imaging performance of mammographic X-ray equipment |
CEI EN 62467-1 : 2016 | MEDICAL ELECTRICAL EQUIPMENT - DOSIMETRIC INSTRUMENTS AS USED IN BRACHYTHERAPY - PART 1: INSTRUMENTS BASED ON WELL-TYPE IONIZATION CHAMBERS |
EN 62467-1:2015 | Medical electrical equipment - Dosimetric instruments as used in brachytherapy - Part 1: Instruments based on well-type ionization chambers |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
I.S. EN 61267:2006 | MEDICAL DIAGNOSTIC X-RAY EQUIPMENT - RADIATION CONDITIONS FOR USE IN THE DETERMINATION OF CHARACTERISTICS |
BS ISO 16142-1:2016 | Medical devices. Recognized essential principles of safety and performance of medical devices General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards |
ISO 16142-1:2016 | Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards |
I.S. EN 61223-3-2:2008 | EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-2: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT |
IEC 61223-3-2:2007 | Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment |
PD IEC TR 60788:2004 | Medical electrical equipment. Glossary of defined terms |
DIN 6800-1:2016-08 | Procedures of dosimetry with probe-type detectors for photon and electron radiation - Part 1: General |
BS EN 61267:2006 | Medical diagnostic X-ray equipment. Radiation conditions for use in the determination of characteristics |
IEC 61267:2005 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
DIN 6868-161:2013-01 | Image quality assurance in diagnostic X-ray departments - Part 161: RoeV acceptance testing of dental radiographic equipment for digital cone-beam computed tomography |
CEI EN 61267 : 2006 | MEDICAL DIAGNOSTIC X-RAY EQUIPMENT - RADIATION CONDITIONS FOR USE IN THE DETERMINATION OF CHARACTERISTICS |
I.S. EN 62467-1:2015 | MEDICAL ELECTRICAL EQUIPMENT - DOSIMETRIC INSTRUMENTS AS USED IN BRACHYTHERAPY - PART 1: INSTRUMENTS BASED ON WELL-TYPE IONIZATION CHAMBERS |
IEC 62467-1:2009 | Medical electrical equipment - Dosimetric instruments as used in brachytherapy - Part 1: Instruments based on well-type ionization chambers |
EN 61223-3-2:2008 | Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment |
EN 61267:2006 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
IEC 60731:2011+AMD1:2016 CSV | Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy |
IEC 61187:1993 | Electrical and electronic measuring equipment - Documentation |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60601-1-3:2008+AMD1:2013 CSV | Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61267:2005 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO 3534-1:2006 | Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.