IEC 62220-1-1:2015
Current
The latest, up-to-date edition.
Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
12-03-2015
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Corrections of RAW DATA
6 Determination of the DETECTIVE QUANTUM EFFICIENCY
7 Format of conformance statement
8 Accuracy
Annex A (normative) - Determination of LAG EFFECTS
Annex B (informative) - Calculation of the input NOISE
POWER SPECTRUM
Bibliography
Index of defined terms used in this particular standard
IEC 62220-1-1:2015 specifies the method for the determination of the DETECTIVE QUANTUM EFFICIENCY (DQE) of DIGITAL X-RAY IMAGING DEVICES as a function of AIR KERMA and of SPATIAL FREQUENCY for the working conditions in the range of the medical application as specified by the MANUFACTURER. The intended users of this part of IEC 62220 are manufacturers and well equipped test laboratories. This first edition of IEC 62220-1-1 cancels and replaces IEC 62220-1:2003. It constitutes a technical revision of IEC 62220-1:2003 and assures a better alignment with the other parts of the IEC 62220 series. The main changes are as follows:
- necessary modifications have been applied as a consequence of taking into account IEC 61267:2005. This influences HVL values and SNRin2;
- the method for the determination of LAG EFFECTS now considers lag and ghosting compensation;
- as part of the MTF determination, the method of obtaining the final averaged MTF has been restricted (only averaging of the ESF is allowed);
- a description of (optionally) obtaining the diagonal (45°) MTF and NPS has been added.
Committee |
TC 62/SC 62B
|
DevelopmentNote |
Supersedes IEC 62220-1. Stability date: 2017. (03/2015)
|
DocumentType |
Standard
|
Pages |
74
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN EN IEC 62220-1-1 : 2015 | Identical |
BS EN 62220-1-1:2015 | Identical |
NBN EN 62220-1-1 : 2015 | Identical |
PN EN 62220-1-1 : 2015 | Identical |
CEI EN 62220-1-1 : 2016 | Identical |
NF EN 62220-1-1 : 2015 | Identical |
EN 62220-1-1:2015 | Identical |
PNE-FprEN 62220-1-1 | Identical |
UNE-EN 62220-1-1:2015 | Identical |
16/30216785 DC : 0 | BS EN 62667 - MEDICAL ELECTRICAL EQUIPMENT - MEDICAL LIGHT ION BEAM EQUIPMENT - PERFORMANCE CHARACTERISTICS |
I.S. EN IEC 62667:2018 | MEDICAL ELECTRICAL EQUIPMENT - MEDICAL LIGHT ION BEAM EQUIPMENT - PERFORMANCE CHARACTERISTICS |
IEC 60601-2-43:2010+AMD1:2017 CSV | Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures |
16/30342399 DC : 0 | BS EN 60601-2-43:2010/A1 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES |
EN 60601-2-43:2010/A1:2018 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES (IEC 60601-2-43:2010/A1:2017) |
BS EN IEC 62667:2018 | Medical electrical equipment. Medical light ion beam equipment. Performance characteristics |
17/30341818 DC : 0 | BS EN 60601-2-54 ED 1.0/A2 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
EN IEC 62667:2018 | Medical electrical equipment - Medical light ion beam equipment - Performance characteristics |
I.S. EN 60601-2-43:2010 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES |
IEC 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
ISO 15529:2010 | Optics and photonics Optical transfer function Principles of measurement of modulation transfer function (MTF) of sampled imaging systems |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
IEC 62220-1-2:2007 | Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography |
IEC 60601-2-54:2009+AMD1:2015 CSV | Medical electrical equipment - Part 2-54: Particular requirementsfor the basic safety and essential performance of X-ray equipmentfor radiography and radioscopy |
ISO 12233:2017 | Photography — Electronic still picture imaging — Resolution and spatial frequency responses |
IEC 61262-5:1994 | Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 5: Determination of the detective quantum efficiency |
IEC 62220-1-3:2008 | Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-3: Determination of the detective quantum efficiency - Detectors used in dynamic imaging |
IEC 61267:2005 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.