FOREWORD
INTRODUCTION
1 Scope
2 Types of voltage waveform
3 Procedure
4 Equipment
5 Test voltages
6 Sensitivity
7 Calibration
Annex A (normative) - Minimum voltage levels
Annex B (informative) - Example of an artificial fault device
Annex C (informative) - Notes on the use of spark testing
machines
Bibliography
IEC 62230:2006+A1:2013 The spark-test method specified in this standard is intended for the detection of defects in the insulation or sheathing layers of electric cables. For single core cables with no outer metallic layer, the general process is accepted as being equivalent to subjecting samples of those cables to a voltage test in water. This standard specifies the operational requirements for the spark-test equipment, as well as the principal characteristics, functional parameters and calibration procedures for each type of test equipment. This consolidated version consists of the first edition (2006) and its amendment 1 (2013). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 20
|
DevelopmentNote |
Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
74
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
SN EN 62230:2007 | Identical |
NF EN 62230 : 2007 AMD 1 2014 | Identical |
NEN EN IEC 62230 : 2007 AMD 1 2014 | Identical |
PN EN 62230 : 2007 AMD 1 2014 | Identical |
VDE 0481-2230 : 2014 | Identical |
DIN EN 62230 : 2014 | Identical |
BS EN 62230 : 2007 | Identical |
UNE-EN 62230:2007 | Identical |
EN 62230:2007/A1:2014 | Identical |
BS EN 60229:2008 | Electric cables. Tests on extruded oversheaths with a special protective function |
UNE-EN 50620:2017 | Electric cables - Charging cables for electric vehicles |
CEI EN 60229 : 2010 | ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION |
CEI 18-49 : 2013 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS |
11/30253626 DC : 0 | BS EN 61196-2 ED.3 - COAXIAL COMMUNICATION CABLES - PART 2: SECTIONAL SPECIFICATION FOR SEMI-RIGID CABLES WITH POLYTERAFLUOROETHYLENE (PTFE) DIELECTRIC |
BS IEC 61196-9-1:2015 | Coaxial communication cables Flexible RF coaxial cables. Blank detail specification |
NF EN 61138 : 2008 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
05/30136422 DC : DRAFT JULY 2005 | |
BS EN 61138:1998 | Cables for portable earthing and short-circuiting equipment |
I.S. EN 50618:2014 | ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS |
I.S. EN 60229:2008 | ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION |
I.S. EN 61138:2008 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
I.S. EN 50620:2017 | ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES |
EN 61138:2007 | CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
EN 60229:2008 | Electric cables - Tests on extruded oversheaths with a special protective function |
EN 50117-4-1 : 2008 AMD 1 2013 | COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
BS IEC 61196-9:2014 | Coaxial communication cables Sectional specification for RF flexible cables |
UNE-EN 50117-4-1:2010 | Coaxial cables - Part 4-1: Sectional specification for cables for BCT cabling in accordance with EN 50173 - Indoor drop cables for systems operating at 5 MHz - 3 000 MHz |
NF EN 50117-4-1 : 2008 AMD 1 2013 | COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
IEC 61196-9:2014 | Coaxial communication cables - Part 9: Sectional specification for RF flexible cables |
UNE-HD 603-5X:2007 | Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section X: Polyolefin sheathed cables without concentric conductor (Type 5X-1) |
I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
UNE-IEC 60092-350:2015 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
CEI EN 50620 : 1ED 2017 | ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES |
IEC 60092-350:2014 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
IEC 61196-8-1:2012 | Coaxial communication cables - Part 8-1: Blank detail specification for semi-flexible cables with polytetrafluoroethylene (PTFE) dielectric |
IEC 62930:2017 | Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC |
IEC 63010-2:2017 | Halogen-free thermoplastic insulated and sheathed flexible cables of rated voltages up to and including 300/300 V - Part 2: Test methods |
IEC 61196-7:2011 | Coaxial communication cables - Part 7: Sectional specification for cables for BCT cabling in accordance with ISO/IEC 15018 - Indoor drop cables for systems operating at 5 MHz - 3 000 MHz |
PREN 50620 : DRAFT 2014 | CHARGING CABLES FOR ELECTRIC VEHICLES |
IEC 61196-6:2009 | Coaxial communication cables - Part 6: Sectional specification for CATV drop cables |
UNE-EN 50618:2015 | Electric cables for photovoltaic systems |
BS EN 50618:2014 | Electric cables for photovoltaic systems (BT(DE/NOT)258) |
UNE-HD 603-5N:2007 | Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section N: PVC sheathed cables without concentric conductor. (Type 5N) |
NF EN 60229 : 2008 | ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION |
EN 61196-10:2016/AC:2016-02 | COAXIAL COMMUNICATION CABLES - PART 10: SECTIONAL SPECIFICATION FOR SEMI-RIGID CABLES WITH POLYTETRAFLUOROETHYLENE (PTFE) DIELECTRIC |
UNE-EN 61196-10:2016 | Coaxial communication cables - Part 10: Sectional specification for semi-rigid cables with polytetrafluoroethylene (PTFE) dielectric |
API SPEC 17E : 2017 | SPECIFICATION FOR SUBSEA UMBILICALS |
BS EN 50117-4-1 : 2008 | COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
IEC 61196-9-1:2015 | Coaxial communication cables - Part 9-1: Flexible RF coaxial cables - Blank detail specification |
IEC 61196-4:2015 | Coaxial communication cables - Part 4: Sectional specification for radiating cables |
BS EN 61196-10:2016 | Coaxial communication cables Sectional specification for semi-rigid cables with polytetrafluoroethylene (PTFE) dielectric |
BS EN 50620:2017 | Electric cables. Charging cables for electric vehicles (BT(DE/NOT)259) |
NF EN 61196-10 : 2016 | COAXIAL COMMUNICATION CABLES - PART 10: SECTIONAL SPECIFICATION FOR SEMI-RIGID CABLES WITH POLYTETRAFLUOROETHYLENE (PTFE) DIELECTRIC |
IEC 62821-2:2015 | Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 2: Test methods |
EN 50620:2017 | Electric cables - Charging cables for electric vehicles |
IEC 61138:2007 | Cables for portable earthing and short-circuiting equipment |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
IEC 61196-11:2016 | Coaxial communication cables - Part 11: Sectional specification for semi-rigid cables with polyethylene (PE) dielectric |
IEC 61196-8:2012 | Coaxial communication cables - Part 8: Sectional specification for semi-flexible cables with polytetrafluoroethylene (PTFE) dielectric |
IEC 60229:2007 | Electric cables - Tests on extruded oversheaths with a special protective function |
I.S. EN 61196-10:2016 | COAXIAL COMMUNICATION CABLES - PART 10: SECTIONAL SPECIFICATION FOR SEMI-RIGID CABLES WITH POLYTETRAFLUOROETHYLENE (PTFE) DIELECTRIC |
16/30326340 DC : 0 | BS EN 63010-2 - ELECTRIC CABLES - HALOGEN-FREE THERMOPLASTIC INSULATED AND SHEATHED FLEXIBLE CABLES OF RATED VOLTAGES UP TO AND INCLUDING 300/300 V - PART 2: TEST METHODS |
14/30288755 DC : 0 | BS EN 50620 - CHARGING CABLES FOR ELECTRIC VEHICLES |
12/30265027 DC : 0 | BS EN 61196-9 ED.1 - COAXIAL COMMUNICATION CABLES - PART 9: SECTIONAL SPECIFICATION FOR FLEXIBLE RF COAXIAL CABLES |
I.S. EN 50117-4-1:2008 | COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
EN 50618:2014 | Electric cables for photovoltaic systems |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.