IEC 62498-2:2010 deals with the environmental influences on fixed electrical installations for traction power supply and equipment essential to operate a railway:
- in open air;
- in covered areas;
- in tunnels;
- within enclosures placed in the above-mentioned areas.
Such influences include altitude, temperature and humidity, air movement, rain, snow, hail, ice, sand, solar radiation, lightning, pollution, vibration, shocks, EMC and earthquakes.The contents of the corrigendum of November 2010 have been included in this copy.
Committee |
TC 9
|
DevelopmentNote |
Stability Date: 2019. (09/2017)
|
DocumentType |
Standard
|
Pages |
39
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
SAC GB/T 32347.2 : 2015 | Identical |
PREN 50119 : DRAFT 2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
17/30341013 DC : DRAFT AUG 2017 | BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
11/30215604 DC : 0 | BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 62695:2014 | Railway applications - Fixed installations - Traction transformers |
IEC 62505-2:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
IEC 62589:2010 | Railway applications - Fixed installations - Harmonisation of the rated values for converter groups and tests on converter groups |
IEC 62724:2013 | Railway applications - Fixed installations - Electric traction - Insulating synthetic rope assemblies for support of overhead contact lines |
IEC 62848-1:2016 | Railway applications - DC surge arresters and voltage limiting devices - Part 1: Metal-oxide surge arresters without gaps |
ISO/TR 21245-2:2016 | Railway applications Rail project planning process Part 2: Conditions |
IEC 60913:2013 | Railway applications - Fixed installations - Electric traction overhead contact lines |
IEC 62505-1:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV |
IEC 62498-3:2010 | Railway applications - Environmental conditions for equipment - Part 3: Equipment for signalling and telecommunications |
ISO 4354:2009 | Wind actions on structures |
IEC 62236-5:2008 | Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus |
IEC 60913:2013 | Railway applications - Fixed installations - Electric traction overhead contact lines |
IEC 61992-4:2006+AMD1:2015 CSV | Railway applications - Fixed installations - DC switchgear - Part 4:Outdoor d.c. disconnectors, switch-disconnectors and earthing switches |
IEC 60721-2-1:2013 | Classification of environmental conditions - Part 2-1: Environmental conditions appearing in nature - Temperature and humidity |
IEC 60721-2-2:2012 | Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
IEC 62497-2:2010 | Railway applications - Insulation coordination - Part 2: Overvoltages and related protection |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 61992-1:2006+AMD1:2014 CSV | Railway applications - Fixed installations - DC switchgear - Part 1:General |
IEC 62497-1:2010+AMD1:2013 CSV | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment |
IEC 60721-2-3:2013 | Classification of environmental conditions - Part 2-3: Environmental conditions appearing in nature - Air pressure |
IEC 62498-1:2010 | Railway applications - Environmental conditions for equipment - Part 1: Equipment on board rolling stock |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.