IEC 62642-2-3:2010
Current
The latest, up-to-date edition.
Alarm systems - Intrusion and hold-up systems - Part 2-3: Intrusion detectors - Microwave detectors
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, English - French
14-12-2010
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Dimensions and requirements of the
standardised test magnets
Annex B (normative) - General testing matrix
Annex C (informative) - Walk test diagrams
Annex D (informative) - Equipment for walk test velocity control
Annex E (informative) - Immunity to microwave signal interference
by fluorescent lights
Annex F (informative) - Example list of small tools
Annex G (normative) - Test for resistance to re-orientation of
adjustable mountings
Bibliography
IEC 62642-2-3:2010 is for microwave detectors installed in buildings and provides for security grades 1 to 4 (see IEC 62642-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see IEC 62599-1).
Committee |
TC 79
|
DevelopmentNote |
Supersedes IEC 60839-2-2 and IEC 60839-2-5. (10/2011) Stability Date: 2017. (12/2017)
|
DocumentType |
Standard
|
Pages |
80
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 62642-6:2011 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
IEC 62642-1:2010 | Alarm systems - Intrusion and hold-up systems - Part 1: System requirements |
IEC 62599-1:2010 | Alarm systems - Part 1: Environmental test methods |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 62599-2:2010 | Alarm systems - Part 2: Electromagnetic compatibility - Immunity requirements for components of fire and security alarm systems |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |