IEC 62689-2:2016
Current
The latest, up-to-date edition.
Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 2: System aspects
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
13-05-2016
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, abbreviations and symbols
4 Choice of FPI/DSU requirements related to
fault detection according to network operation
mode and fault type
5 Fault detecting principles according to network
and fault type
Annex A (informative) - Example of a possible solution
for fault detection through FPIs/DSUs on closed
loop feeder
Annex B (informative) - Example of fault detection
coordination technique among FPIs/DSUs and
MV feeder protection relays
Bibliography
IEC 62689-2:2016 describes electric phenomena and electric system behaviour during faults, according to the most widely diffused distribution system architecture and to fault typologies, to define the functional requirements for fault passage indicators (FPI) and distribution substation units (DSU) (including their current and/or voltage sensors), which are, respectively, a device or a device/combination of devices and/or of functions able to detect faults and provide indications about their localization. By localization of the fault is meant the fault position with respect to the FPI/DSU installation point on the network (upstream or downstream from the FPI/DSU's location) or the direction of the fault current flowing through the FPI itself. The fault localization may be obtained
- directly from the FPI/DSU, or
- from a central system using information from more FPIs or DSUs, considering the features and the operating conditions of the electric system where the FPIs/DSUs are installed. This part of IEC 62689 is therefore aimed at helping users in the appropriate choice of FPIs/DSUs (or of a system based on FPI/DSU information) properly operating in their networks, considering adopted solutions and operation rules (defined by tradition and/or depending on possible constraints concerning continuity and quality of voltage supply defined by a national regulator), and also taking into account complexity of the apparatus and consequent cost. This part of IEC 62689 is mainly focused on system behaviour during faults, which is the "core" of FPI/DSU fault detection capability classes described in IEC 62689-1, where all requirements are specified in detail.
DevelopmentNote |
Stability date: 2020. (05/2016)
|
DocumentType |
Standard
|
Pages |
98
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
EN 62689-2:2017 | Identical |
NEN EN IEC 62689-2 : 2017 | Identical |
BS EN 62689-2:2017 | Identical |
UNE-EN 62689-2:2017 | Identical |
DIN EN 62689-2 : 2018 | Identical |
SN EN 62689-2 : 2017 | Identical |
PNE-FprEN 62689-2 | Identical |
NF EN 62689-2 : 2017 | Identical |
PN EN 62689-2 : 2017 | Identical |
VDE 0414-689-2 : 2018 | Identical |
IEC 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
PD IEC/TR 62689-100:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes Requirements and proposals for the IEC 61850 series data model extensions to support fault passage indicators applications |
IEC TR 62689-100:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 100: Requirements and proposals for the IEC 61850 series data model extensions to support fault passage indicators applications |
EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
BS EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements |
I.S. EN 62689-1:2016 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
IEC 60044-7:1999 | Instrument transformers - Part 7: Electronic voltage transformers |
IEC 61850-7-2:2010 | Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI) |
IEC 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
IEC 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
IEC 60870-5-104:2006+AMD1:2016 CSV | Telecontrol equipment and systems - Part 5-104: Transmission protocols - Network access for IEC 60870-5-101 using standardtransport profiles |
IEC 61869-1:2007 | Instrument transformers - Part 1: General requirements |
IEC 60870-5-101:2003+AMD1:2015 CSV | Telecontrol equipment and systems - Part 5-101: Transmissionprotocols - Companion standard for basic telecontrol tasks |
IEC 61850-7-3:2010 | Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes |
IEC 61869-6:2016 | Instrument transformers - Part 6: Additional general requirements for low-power instrument transformers |