IEC PAS 61076-3-115:2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Connectors for electronic equipment - Part 3-115: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
17-06-2009
English
28-11-2005
FOREWORD
1 General data
1.1 Scope
1.2 Normative references
1.3 IEC type designation
2 Terms and definitions
3 Dimensional information
3.1 Common features
3.2 General
3.3 Contact arrangement of all connector types
3.4 IP 65 and IP 67 sealing
3.5 Industrial IEC 60603-7 variant 12 - Push-pull coupling
3.5.1 Industrial IEC 60603-7 variant 12, fixed connectors
3.5.2 Industrial IEC 60603-7 variant 12, free connectors
3.6 Termination and mounting information
3.7 General
3.8 Mounting information for variant 12 fixed connectors
4 Gauges
4.1 Connectors, IEC 60603-7 interface
5 Characteristics
5.1 Climatic category
5.2 Electrical
5.2.1 Clearance and creepage distances
5.2.2 Voltage proof
5.2.3 Current-carrying capacity
5.2.4 Mating cycles with power applied
5.2.5 Initial contact resistance
5.2.6 Input-to-output resistance
5.2.7 Resistance unbalance
5.2.8 Initial insulation resistance
5.3 Transmission characteristics
5.3.1 General
5.3.2 Mechanical
5.3.3 Mechanical operation
5.3.4 Effectiveness of connector coupling devices
transversal
5.3.5 Effectiveness of connector coupling devices
5.3.6 Separation and engagement forces
6 Test schedule
6.1 General
6.2 Test procedures and measuring methods
6.3 Preconditioning
6.4 Wiring and mounting of specimens
6.4.1 Wiring
6.4.2 Mounting
6.5 Arrangement for contact resistance test
6.6 Arrangement for dynamic stress tests (test phase AP2)
6.7 Basic (minimum) test schedule
6.8 Full test schedule
6.8.1 Test preliminary group P
6.8.2 Test group P
6.8.3 Test group AP
6.8.4 Test group BP
6.8.5 Test group CP
6.8.6 Test group DP
6.8.7 Test group EP
Covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking and a variety of different mounting configurations and termination types.
DocumentType |
Miscellaneous Product
|
Pages |
20
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN NPR IEC/PAS 61076-3-115 : 2005 | Identical |
IEC 60603-7-1:2011 | Connectors for electronic equipment - Part 7-1: Detail specification for 8-way, shielded, free and fixed connectors |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60603-7-2:2010 | Connectors for electronic equipment - Part 7-2: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
IEC PAS 60603-7-3:2004 | Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
IEC 61156-2:2010 | Multicore and symmetrical pair/quad cables for digital communications - Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz - Horizontal floor wiring - Sectional specification |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
IEC 61156-4:2009 | Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification |
IEC 60603-7-5:2010 | Connectors for electronic equipment - Part 7-5: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEC 61156-3:2008 | Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification |
IEC 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60603-7-7:2010 | Connectors for electronic equipment - Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |