• There are no items in your cart

IEC PAS 63151:2018

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Vector measurement-based systems (Frequency range of 30 MHz to 6 GHz)

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

31-12-2021

Language(s)

English

Published date

15-01-2018

€415.86
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Overview of the measurement procedure
6 Measurement system specifications
7 Protocol for SAR assessment
8 Uncertainty estimation
9 Measurement report
Annex A (normative) - Phantom specifications
Annex B (normative) - Calibration and characterization
        of dosimetric probes
Annex C (informative) - Field Reconstruction Techniques
Annex D (normative) - SAR measurement system
        verification and validation
Annex E (informative) - Interlaboratory comparisons
Annex F (normative) - Validation antennas
Annex G (normative) - Calibration of Reference Antennas
Annex H (normative) - General considerations on uncertainty
        estimation
Annex I (normative) - Evaluation of the measurement
        system uncertainty
Bibliography

IEC PAS 63151:2018(E) specifies protocols and test procedures for the reproducible measurement of the peak spatial-average specific absorption rate (psSAR) induced inside a simplified model of the head or the body by radio-frequency (RF) transmitting devices, with a defined uncertainty. It provides requirements for systems using vector measurement-based systems. Such systems determine the psSAR by 3D field reconstruction within the volume of interest by specifying the requirements for the measurement system, calibration, uncertainty assessment and validation methods. The protocols and procedures apply for a significant majority of people including children during use of hand-held and body-worn wireless communication devices.
This PAS is applicable to any wireless communication device intended to be used at a position near the human head or body at distances up to and including 200 mm. This PAS can be employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, combined with other RF-transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range is from 30 MHz to 6 GHz.
The system validation procedures provided within this PAS cover frequencies from 600 MHz to 6 GHz.
Some specifications (e.g., validation antennas and other procedures or requirements) are not yet defined over the full frequency range within the scope of this document but will be included in a future revision.
The device categories covered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers, desktop, laptop devices, multi-band, multi-antenna, and push-to-talk devices.

Committee
TC 106
DevelopmentNote
Stability Date: 2020. (01/2018)
DocumentType
Miscellaneous Product
Pages
127
PublisherName
International Electrotechnical Committee
Status
Withdrawn

Standards Relationship
PD IEC/PAS 63151:2018 Identical

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
IEC 62209-2:2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)
IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
IEC 62479:2010 Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
ISO/IEC Guide 98-1:2009 Uncertainty of measurement — Part 1: Introduction to the expression of uncertainty in measurement
ISO/IEC Guide 43-1:1997 Proficiency testing by interlaboratory comparisons Part 1: Development and operation of proficiency testing schemes
IEEE 1720-2012 IEEE Recommended Practice for Near-Field Antenna Measurements
IEEE 1528-2013 REDLINE IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques
IEC TR 62630:2010 Guidance for evaluating exposure from multiple electromagnetic sources
ECA 2-07 : 1997 EAL STRATEGY TO ACHIEVE COMPARABILITY OF RESULTS IN CALIBRATION AND TESTING
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.