IEC TR 60854:1986
Current
The latest, up-to-date edition.
Methods of measuring the performance of ultrasonic pulse-echo diagnostic equipment
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
30-10-1986
Contents
Foreword
Preface
Clause
1. Scope
2. Object
3. Definitions
4. Acoustic frequency
4.1 General
4.2 Measurement of working frequency
5. Echo detection capability
5.1 General
5.2 Measurement method
6. Grain-range dependence
6.1 General
6.2 Measurement method
7. Display characteristics
7.1 General
7.2 A-mode displays
7.3 B-mode displays
8. Geometrical resolution
8.1 General
8.2 Axial resolution measurement - A-mode
8.3 Lateral resolution measurement - A-mode
8.4 Resolution measurement - B-mode displays
9. Geometrical alignment accuracy
9.1 General
9.2 Depth calibration
9.3 B-scan alignment
Appendix A - Reference targets and interfaces
Appendix B - High-frequency attenuator
Appendix C - Working frequency
Appendix D - References
Defines parameters and outlines test methods for measuring performance of pulse-echo medical diagnostic systems that employ single-element transducers and operate in the 0.5 MHz to 25 MHz acoustic frequency range. Provides a generally acceptable basis for measuring and reporting the principal performance parameters of complete diagnostic systems. The performance parameters specified, and the corresponding methods of measurement, have been chosen in order to provide a basis for comparison between similar apparatus of different makes intended for the same kind of diagnostic application. The set of results and values obtained from the use of the recommended methods will provide useful criteria for predicting the performance of equipment in appropriate diagnostic applications. In order that the recommendations should be suitable for general applications, methods have been specified which do not require unusual and expensive equipment for their implementation. Where one basic diagnostic system accommodates more than one option in respect of a particular system component, such as the transducer, it is intended that, wherever appropriate, each option be regarded as a separate system. Has the status of a technical report.
Committee |
TC 87
|
DevelopmentNote |
Stability Date: 2020. (09/2017)
|
DocumentType |
Technical Report
|
Pages |
47
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
BIS IS 13069 : 1991(R1997) | Identical |
DIN IEC 60854:1993-09 (Draft) | Identical |
I.S. EN 61102:1994 | MEASUREMENT AND CHARACTERISATION OF ULTRASONIC FIELDS USING HYDROPHONES IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ |
I.S. EN 61391-1:2006 | Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of system point-spread function response |
04/30115966 DC : DRAFT JUL 2004 | |
CEI EN 61161 : 2014 | ULTRASONICS - POWER MEASUREMENT - RADIATION FORCE BALANCES AND PERFORMANCE REQUIREMENTS |
BS EN 62127-1 : 2007 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ |
NF EN 62127-1 : 2008 AMD 1 2013 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ |
EN 61161:2013 | Ultrasonics - Power measurement - Radiation force balances and performance requirements |
EN 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
EN 61157:2007/A1:2013 | STANDARD MEANS FOR THE REPORTING OF THE ACOUSTIC OUTPUT OF MEDICAL DIAGNOSTIC ULTRASONIC EQUIPMENT (IEC 61157:2007/A1:2013) |
PD IEC/TR 62799:2013 | Models for evaluation of thermal hazard in medical diagnostic ultrasonic fields |
BS EN 61102:1994 | Specification for measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz |
BS EN 61828:2002 | Ultrasonics. Focusing transducers. Definitions and measurement methods for the transmitted fields |
08/30177589 DC : DRAFT FEB 2008 | BS EN 62359 - ULTRASONIC - FIELD CHARACTERIZATION - TEST METHODS FOR THE DETERMINATION OF THERMAL AND MECHANICAL INDICES RELATED TO MEDICAL DIAGNOSTIC ULTRASONIC FIELDS |
BS EN 61157 : 2007 | STANDARD MEANS FOR THE REPORTING OF THE ACOUSTIC OUTPUT OF MEDICAL DIAGNOSTIC ULTRASONIC EQUIPMENT |
CEI EN 61689 : 2013 | ULTRASONICS - PHYSIOTHERAPY SYSTEMS - FIELD SPECIFICATIONS AND METHODS OF MEASUREMENT IN THE FREQUENCY RANGE 0,5 MHZ TO 5 MHZ |
I.S. EN 61987-1:2007 | INDUSTRIAL-PROCESS MEASUREMENT AND CONTROL - DATA STRUCTURES AND ELEMENTS IN PROCESS EQUIPMENT CATALOGUES - PART 1: MEASURING EQUIPMENT WITH ANALOGUE AND DIGITAL OUTPUT |
CEI EN 61828 : 2003 | ULTRASONICS - FOCUSING TRANSDUCERS - DEFINITIONS AND MEASUREMENT METHODS FOR THE TRANSMITTED FIELDS |
I.S. EN 62359:2011 | ULTRASONICS - FIELD CHARACTERIZATION - TEST METHODS FOR THE DETERMINATION OF THERMAL AND MECHANICAL INDICES RELATED TO MEDICAL DIAGNOSTIC ULTRASONIC FIELDS |
EN 61828:2001 | Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields |
I.S. EN 61157:2007 | STANDARD MEANS FOR THE REPORTING OF THE ACOUSTIC OUTPUT OF MEDICAL DIAGNOSTIC ULTRASONIC EQUIPMENT (IEC 61157:2007 (EQV)) |
BS EN 61161:2013 | Ultrasonics. Power measurement. Radiation force balances and performance requirements |
BS 7887:1997 | Ultrasonics. Real-time pulse-echo systems. Guide for test procedures to determine performance specifications |
I.S. EN 61266:1997 | ULTRASONICS - HAND-HELD PROBE DOPPLER FOETAL HEARTBEAT DETECTORS - PERFORMANCE REQUIREMENTS AND METHODS OF MEASUREMENT AND REPORTING |
07/30161032 DC : 0 | BS EN 61391-2 - ULTRASONICS - PULSE ECHO SCANNERS - PART 2: TECHNIQUES FOR MEASUREMENT OF MAXIMUM DEPTH OF VISUALIZATION AND THE DISPLAYED DYNAMIC RANGE |
BS EN 62359 : 2011 | ULTRASONICS - FIELD CHARACTERIZATION - TEST METHODS FOR THE DETERMINATION OF THERMAL AND MECHANICAL INDICES RELATED TO MEDICAL DIAGNOSTIC ULTRASONIC FIELDS |
I.S. EN 61161:2013 | ULTRASONICS - POWER MEASUREMENT - RADIATION FORCE BALANCES AND PERFORMANCE REQUIREMENTS (IEC 61161:2013 (EQV)) |
IEC TR 62799:2013 | Models for evaluation of thermal hazard in medical diagnostic ultrasonic fields |
BS EN 61689:2013 | Ultrasonics. Physiotherapy systems. Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
CEI EN 61391-1 : 2007 | ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE |
15/30326099 DC : 0 | BS EN 61828 - ULTRASONICS - FOCUSING TRANSDUCERS - DEFINITIONS AND MEASUREMENT METHODS FOR THE TRANSMITTED FIELDS |
BS EN 61987-1:2007 | Industrial-process measurement and control. Data structures and elements in process equipment catalogues Measuring equipment with analogue and digital output |
05/30141146 DC : DRAFT OCT 2005 | |
CEI EN 61266 : 1998 | ULTRASONICS - HAND-HELD PROBE DOPPLER FOETAL HEARTBEAT DETECTORS - PERFORMANCE REQUIREMENTS AND METHODS OF MEASUREMENT AND REPORTING |
ASTM D 139 : 2016 : REDLINE | Standard Test Method for Float Test for Bituminous Materials |
IEC 61987-1:2006 | Industrial-process measurement and control - Data structures and elements in process equipment catalogues - Part 1: Measuring equipment with analogue and digital output |
IEC 61161:2013 | Ultrasonics - Power measurement - Radiation force balances and performance requirements |
IEC 61391-1:2006+AMD1:2017 CSV | Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of point-spread function response |
IEC 61828:2001 | Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields |
IEC 62127-1:2007+AMD1:2013 CSV | Ultrasonics - Hydrophones - Part 1: Measurement and characterizationof medical ultrasonic fields up to 40 MHz |
IEC 61266:1994 | Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting |
IEC 61157:2007+AMD1:2013 CSV | Standard means for the reporting of the acoustic output of medicaldiagnostic ultrasonic equipment |
BS EN 61391-1 : 2006 | ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE |
BS EN 61266:1995 | Ultrasonics. Hand-held probe Doppler foetal heartbeat detectors. Performance requirements and methods of measurement and reporting |
15/30330344 DC : 0 | BS EN 61391-1+A1 - ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF POINT-SPREAD FUNCTION RESPONSE |
11/30228838 DC : 0 | BS EN 61157 A1 - STANDARD MEANS FOR THE REPORTING OF THE ACOUSTIC OUTPUT OF MEDICAL DIAGNOSTIC ULTRASONIC EQUIPMENT |
11/30230872 DC : 0 | BS EN 61689 - ULTRASONICS - PHYSIOTHERAPY SYSTEMS - FIELD SPECIFICATIONS AND METHODS OF MEASUREMENT IN THE FREQUENCY RANGE 0,5 MHZ TO 5 MHZ |
I.S. EN 61689:2013 | ULTRASONICS - PHYSIOTHERAPY SYSTEMS - FIELD SPECIFICATIONS AND METHODS OF MEASUREMENT IN THE FREQUENCY RANGE 0,5 MHZ TO 5 MHZ (IEC 61689:2013 (EQV)) |
11/30228497 DC : 0 | BS EN 61161 - ULTRASONICS - POWER MEASUREMENT - RADIATION FORCE BALANCES AND PERFORMANCE REQUIREMENTS |
I.S. EN 62127-1:2007 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007 (EQV)) |
EN 62127-1:2007/A1:2013 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007/A1:2013) |
IEC 62359:2010+AMD1:2017 CSV | Ultrasonics - Field characterization - Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields |
IEC 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
EN 61987-1:2007 | Industrial-process measurement and control - Data structures and elements in process equipment catalogues - Part 1: Measuring equipment with analogue and digital output |
EN 61391-1:2006/A1:2017 | ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE (IEC 61391-1:2006/A1:2017) |
EN 61266:1995 | Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting |
EN 61102:1993/A1:1994 | MEASUREMENT AND CHARACTERISATION OF ULTRASONIC FIELDS USING HYDROPHONES IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ |
EN 62359:2011/A1:2018 | ULTRASONICS - FIELD CHARACTERIZATION - TEST METHODS FOR THE DETERMINATION OF THERMAL AND MECHANICAL INDICES RELATED TO MEDICAL DIAGNOSTIC ULTRASONIC FIELDS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.