• IEC TR 60909-4:2000

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Short-circuit currents in three-phase a.c. systems - Part 4: Examples for the calculation of short-circuit currents

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  31-12-2021

    Language(s):  English - French, Spanish, Castilian

    Published date:  21-07-2000

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 General
          1.1 Scope and object
          1.2 Reference documents
          1.3 Definitions, symbols and indices, and equations
    2 Positive-sequence, negative-sequence and zero-sequence
          impedance's of electrical equipment
          2.1 Overhead lines, cables and short-circuit
                 limiting reactors
          2.2 Transformers
          2.3 Generators and power-station units
    3 Calculation of short-circuit currents in a low-voltage
          system Un = 400 V
          3.1 Problem
          3.2 Determination of the positive-sequence
                 impedance's
                 3.2.1 Network feeder
                 3.2.2 Transformers
                 3.2.3 Lines (cables and overhead lines)
          3.3 Determination of the zero-sequence impedance's
                 3.3.1 Transformers
                 3.3.2 Lines (cables and overhead lines)
          3.4 Calculation of Ik and ip for three-phase short
                 circuits
                 3.4.1 Short-circuit location F1
                 3.4.2 Short-circuit location F2
                 3.4.3 Short-circuit location F3
          3.5 Calculation of Ikl and ip1 for line-to-earth
                 short circuits
                 3.5.1 Short-circuit location F1
                 3.5.2 Short-circuit location F2
                 3.5.3 Short-circuit location F3
          3.6 Collection of results
    4 Calculation of three-phase short-circuit currents in
          a medium-voltage system - influence of motors
          4.1 Problem
          4.2 Complex calculation with absolute quantities
          4.3 Calculation with short-circuit reactances of
                 electrical equipment
          4.4 Calculation with per-unit quantities
          4.5 Calculation with the superposition method
    5 Calculation of three-phase short-circuit currents for
          a power station unit and the auxiliary network
          5.1 Problem
          5.2 Short-circuit impedance's of electrical
                 equipment
                 5.2.1 Network feeder
                 5.2.2 Power-station unit
                 5.2.3 Auxiliary transformers
                 5.2.4 Low-voltage transformers 2,5 MVA and
                          1,6 MVA
                 5.2.5 Asynchronous motors
          5.3 Calculation of short-circuit currents
                 5.3.1 Short-circuit location F1
                 5.3.2 Short-circuit location F2
                 5.3.3 Short-circuit location F3
                 5.3.4 Short-circuit location F4
                 5.3.5 Short-circuit location F5
    6 Test network for the calculation of short-circuit
          currents with digital programs in accordance with
          IEC 60909-0
          6.1 General
          6.2 High-voltage test network 380 kV/110 kV/30 kV
                 6.2.1 Network topology and data
                 6.2.2 Short-circuit impedance's of electrical
                          equipment
          6.3 Results
                 6.3.1 Three-phase short-circuit currents
                 6.3.2 Line-to-earth short-circuit currents

    Abstract - (Show below) - (Hide below)

    Intended to give help for the application of IEC 60909-0 for the calculation of short-circuit currents in 50 Hz or 60 Hz three-phase a.c. systems. It does not include additional requirements but does give support for the modelling of electrical equipment in the positive-sequence, the negative-sequence and the zero-sequence system and the practical execution of calculations in a low-voltage system, a medium-voltage system with asynchronous motors and a power-station unit with its auxiliary network feeding a large number of medium-voltage asynchronous motors and low-voltage motor groups.

    General Product Information - (Show below) - (Hide below)

    Committee TC 73
    Development Note Stability Date: 2017. (09/2017)
    Document Type Technical Report
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEC TR 60909-2:2008 Short-circuit currents in three-phase a.c. systems - Part 2: Data of electrical equipment for short-circuit current calculations
    EN 60909-0:2016 Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents
    12/30270636 DC : 0 BS EN 60909-0 - SHORT-CIRCUIT CURRENTS IN THREE-PHASE A.C. SYSTEMS - PART 0: CALCULATION OF CURRENTS
    UNE-IEC/TR 60909-2:2010 IN Short-circuit currents in three-phase a.c. systems - Part 2: Data of electrical equipment for short-circuit current calculations
    BS EN 60909-0:2016 Short-circuit currents in three-phase a.c. systems Calculation of currents
    I.S. EN 60909-0:2016 SHORT-CIRCUIT CURRENTS IN THREE-PHASE A.C. SYSTEMS - PART 0: CALCULATION OF CURRENTS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60038:2009 IEC standard voltages
    IEC TR 60909-1:2002 Short-circuit currents in three-phase a.c. systems - Part 1: Factors for the calculation of short-circuit currents according to IEC 60909-0