IEC TR 61000-3-14:2011
Current
The latest, up-to-date edition.
Electromagnetic compatibility (EMC) - Part 3-14: Assessment of emission limits for harmonics, interharmonics, voltage fluctuations and unbalance for the connection of disturbing installations to LV power systems
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, English - French
20-10-2011
IEC TR 61000-3-14:2011 is a Technical Report which provides guidance on principles that can be used as the basis for determining the requirements for the connection of disturbing installations to low voltage (LV) public power systems. For the purposes of this part of IEC 61000, a disturbing installation means an installation (which may be a load or a generator) that produces disturbances: harmonics and/or interharmonics, voltage flicker and/or rapid voltage changes, and/or voltage unbalance. The primary objective is to provide guidance to system operators or owners for engineering practices, which will facilitate the provision of adequate service quality for all connected customer installations. In addressing installations, this report is not intended to replace equipment standards for emission limits. This report addresses the allocation of the capacity of the system to absorb disturbances. It does not address how to mitigate disturbances, nor does it address how the capacity of the system can be increased.
Committee |
TC 77/SC 77A
|
DevelopmentNote |
Stability Date: 2018. (09/2017)
|
DocumentType |
Technical Report
|
Pages |
102
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
FD IEC/TR 61000-3-14:2022 | Identical |
PD IEC/TR 61000-3-14:2011 | Identical |
NEN NPR IEC/TR 61000-3-14 : 2011 | Identical |
SA/SNZ TR IEC 61000.3.14:2013 | Identical |
PD IEC/TR 61850-90-17:2017 | Communication networks and systems for power utility automation Using IEC 61850 to transmit power quality data |
CEI EN 61000-3-12 : 2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE |
EN 61000-3-12:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011) |
BS EN 62920:2017 | Photovoltaic power generating systems. EMC requirements and test methods for power conversion equipment |
UNE-EN 61000-3-12:2012 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and |
CEI EN 62920 : 1ED 2018 | PHOTOVOLTAIC POWER GENERATING SYSTEMS - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT |
17/30354643 DC : 0 | BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
I.S. EN 62920:2017 | PHOTOVOLTAIC POWER GENERATING SYSTEMS - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT |
16/30332623 DC : 0 | BS EN 62920 ED 1.0 - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT APPLYING TO PHOTOVOLTAIC POWER GENERATING SYSTEMS |
EN IEC 62933-2-1:2018 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
I.S. EN IEC 62933-2-1:2018 | ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
IEC TR 61850-90-17:2017 | Communication networks and systems for power utility automation - Part 90-17: Using IEC 61850 to transmit power quality data |
IEC TS 62749:2015 | Assessment of power quality - Characteristics of electricity supplied by public networks |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
NF EN 62920 : 2017 | PHOTOVOLTAIC POWER GENERATING SYSTEMS - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT |
BS EN 61000-3-12:2011 | Electromagnetic compatibility (EMC) Limits. Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and ≤ 75 A per phase |
I.S. EN 61000-3-12:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011 (EQV)) |
EN 62920:2017 | Photovoltaic power generating systems - EMC requirements and test methods for power conversion equipment |
IEC 62933-2-1:2017 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
IEC TR 60725:2012 | Consideration of reference impedances and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ≤75 A per phase |
IEC TR 61000-3-13:2008 | Electromagnetic compatibility (EMC) - Part 3-13: Limits - Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
IEC 60050-101:1998 | International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics |
IEC 61000-4-15:2010 | Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications |
IEC TR 61000-3-7:2008 | Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
IEC 61000-4-7:2002+AMD1:2008 CSV | Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto |
IEC TR 61000-3-6:2008 | Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.