FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Relevance of test data and special observations
5 Principle
6 Apparatus
7 Calibration and verification
8 Test report
Annex A (normative) - Details of the test equipment
Annex B (normative) - Construction details
Annex C (normative) - Apparatus adjustments
and maintenance
Annex D (informative)
Annex E (informative) - Example of test verification
report
Annex F (informative) - Verification of the performance
of the apparatus by the use of reference
materials
Bibliography
IEC/TS 60695-2-30:2013 describes the apparatus, calibration procedures and basic experimental procedures for the determination of the specific optical density of smoke produced by materials exposed vertically to a radiant heat source with or without the application of a pilot flame. The test specimens are of a defined size. The determination of the optical density is carried out in a pressure-controlled chamber previously calibrated with reference materials. The test methods are only applicable to flat, solid, non-metallic test specimens, of materials used in electrotechnical products. This technical specification does not provide a classification system for the behaviour of materials. The test methods are not applicable for materials that melt and flow away from the direct impingement of heat flux. The test methods are not recommended for further development for electrotechnical products nor are they recommended as the basis for regulation or other controls on smoke release due to the limitations of the physical fire model and the test specimen geometry - see Clause 4. This second edition of IEC/TS 60695-6-30 cancels and replaces the first edition published in 1996. It constitutes a technical revision. The main changes with respect to the previous edition are as follows:
- This publication is to be re-designated as a technical specification.
- The title has been modified to align with the IEC Directives.
- The FOREWORD has been revised and updated.
- An INTRODUCTION has been added.
- The Scope has been updated.
- The normative references have been updated.
- The terms and definitions have been updated.
- Clause 4: Relevance of test data and special observations has been revised.
- Detailed editorial updates have been added throughout the document.
It has the status of a basic safety publication in accordance with IEC Guide 104 and ISO/IEC Guide 51.Keywords: Smoke obscuration, Fire Hazard.
This publication is to be read in conjunction with IEC 60695-6-31:2013.
Committee |
TC 89
|
DevelopmentNote |
Stability date: 2015. Supersedes IEC 60695-6-30. To be read in conjunction with IEC TS 60695-6-31. (04/2013)
|
DocumentType |
Technical Specification
|
Pages |
79
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
NEN NPR IEC/TS 60695-6-30 : 2013 | Identical |
ISO 1923:1981 | Cellular plastics and rubbers — Determination of linear dimensions |
ISO 5659-2:2017 | Plastics — Smoke generation — Part 2: Determination of optical density by a single-chamber test |
ISO 13943:2017 | Fire safety — Vocabulary |
ISO 19706:2011 | Guidelines for assessing the fire threat to people |
IEC 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.