• Shopping Cart
    There are no items in your cart

IEEE 1415 : 2006

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

INDUCTION MACHINERY MAINTENANCE TESTING AND FAILURE ANALYSIS

Withdrawn date

12-09-2023

Published date

01-01-2006

Sorry this product is not available in your region.

1 Overview
  1.1 Scope
  1.2 Purpose
2 Normative references
3 Definitions
4 Maintenance inspections and tests
  4.1 Safety for inspections and tests
  4.2 Maintenance inspections
  4.3 Maintenance tests
5 Determination and investigation of failure occurrence
  5.1 Following a suspected failure
  5.2 Investigation flow chart
  5.3 Data collection
6 Failure analysis
  6.1 Common symptoms and causes
  6.2 Stator failures
  6.3 Rotor failure modes
  6.4 Shaft failures
  6.5 Lubrication and bearing failure modes
  6.6 Structures
  6.7 Ventilation
  6.8 Accessories
Annex A (informative) Bibliography
Annex B (informative) Suggested checklists
Annex C (informative) Failure investigation test methods

Presents maintenance testing and failure analysis guidance for form-wound, squirrel cage, induction machinery rated up to 15 kV.

DevelopmentNote
Supersedes IEEE DRAFT 1415. (10/2007)
DocumentType
Standard
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn

CSA C392 : 2011 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
CSA C392 : 2011 : INC : UPD 2 : 2012 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
CSA C392 : 2011 : INC : UPD 1 : 2011 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
CSA C392 : 2011 : R2016 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT

NEMA MG 1 : 2016 MOTORS AND GENERATORS
NEMA MG 2:2014 Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators
NEMA MG 10:2017 Energy Management Guide for Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors
IEEE 841-2009 IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors--Up to and Including 370 kW (500 hp)
NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
IEEE 389-1996 IEEE Recommended Practice for Testing Electronics Transformers and Inductors
IEEE 95-2002 IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage
ASTM E 1444 : 2005 Standard Practice for Magnetic Particle Testing
IEEE 1434-2014 IEEE Guide for the Measurement of Partial Discharges in AC Electric Machinery
ANSI/NEMA C50.41 : 2012 POLYPHASE INDUCTION MOTORS FOR POWER GENERATION STATIONS
API STD 541 : 2014 FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER
IEEE 1068-2015 IEEE Standard for the Repair and Rewinding of AC Electric Motors in the Petroleum, Chemical, and Process Industries
IEEE 43-2013 REDLINE IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery
IEEE 112-2004 IEEE Standard Test Procedure for Polyphase Induction Motors and Generators
IEEE 286-2000 IEEE Recommended Practice for Measurement of Power Factor Tip-Up of Electric Machinery Stator Coil Insulation

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.