• IEEE C37.47 : 2011

    Current The latest, up-to-date edition.

    SPECIFICATIONS FOR HIGH-VOLTAGE (>1000 V) DISTRIBUTION CLASS CURRENT-LIMITING TYPE FUSES AND FUSE DISCONNECTING SWITCHES

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  03-02-2012

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. Overview
    2. Normative references
    3. General rating information
    4. Design test requirements
    5. Time-current characteristic requirements for
       distribution class current-limiting type fuse refill
       units and fuse units
    6. Conformance tests
    7. Nameplate marking
    8. Application, operation, and maintenance guidelines
    Annex A (informative) - Bibliography

    Abstract - (Show below) - (Hide below)

    Provides specifications for high-voltage (>1000 V) distribution class current-limiting type fuses and associated accessories. Plans for use on alternating current (ac) systems.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes ANSI C37.47. (01/2014)
    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE C37.48.1-2002 GUIDE FOR THE APPLICATION, OPERATION, AND COORDINATION OF HIGH-VOLTAGE (>1000 V) CURRENT-LIMITING FUSES
    MIL-DTL-32483 Base Document:2013 Switchgear, Power, Hard-Mounted, Medium Voltage, Naval Shipboard
    MIL-DTL-917 Revision F:2014 ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR
    IEEE C37.45-2007 DESIGN TESTS AND SPECIFICATIONS FOR HIGH VOLTAGE (> 1000 V) DISTRIBUTION CLASS ENCLOSED SINGLE-POLE AIR SWITCHES
    IEC TR 62655:2013 Tutorial and application guide for high-voltage fuses
    PD IEC/TR 62655:2013 Tutorial and application guide for high-voltage fuses
    IEEE C37.74 : 2014 REQUIREMENTS FOR SUBSURFACE, VAULT AND PAD-MOUNTED LOAD-INTERRUPTER SWITCHGEAR AND FUSED LOAD-INTERRUPTER SWITCHGEAR FOR ALTERNATING CURRENT SYSTEMS UP TO 38 KV
    IEEE C37.20.3 : 2013 METAL-ENCLOSED INTERRUPTER SWITCHGEAR (1 KV-38 KV)

    Standards Referencing This Book - (Show below) - (Hide below)

    IEEE C37.100.1 : 2007 COMMON REQUIREMENTS FOR HIGH VOLTAGE POWER SWITCHGEAR RATED ABOVE 1000 V
    IEEE C37.42-2009 HIGH-VOLTAGE (>1000 V) FUSES AND ACCESSORIES
    IEC 60282-1:2009+AMD1:2014 CSV High-voltage fuses - Part 1: Current-limiting fuses
    IEEE C37.46 : 2010 HIGH-VOLTAGE (>1000 V) EXPULSION AND CURRENT-LIMITING POWER CLASS FUSES AND FUSE DISCONNECTING SWITCHES
    IEEE C37.48 : 2005 APPLICATION, OPERATION, AND MAINTENANCE OF HIGH-VOLTAGE FUSES, DISTRIBUTION ENCLOSED SINGLE-POLE AIR SWITCHES, FUSE DISCONNECTING SWITCHES, AND ACCESSORIES
    IEEE C37.43 : 2008 HIGH-VOLTAGE EXPULSION, CURRENT-LIMITING, AND COMBINATION-TYPE DISTRIBUTION AND POWER CLASS EXTERNAL FUSES, WITH RATED VOLTAGES FROM 1 KV THROUGH 38 KV, USED FOR THE PROTECTION OF SHUNT CAPACITORS
    IEEE C37.40 : 2003 STANDARD SERVICE CONDITIONS AND DEFINITIONS FOR HIGH-VOLTAGE FUSES, DISTRIBUTION ENCLOSED SINGLE-POLE SWITCHES, FUSE DISCONNECTING SWITCHES, AND ACCESSORIES
    IEEE C37.41:2008 HIGH-VOLTAGE (>1000 V) FUSES AND ACCESSORIES
    IEEE C37.45-2007 DESIGN TESTS AND SPECIFICATIONS FOR HIGH VOLTAGE (> 1000 V) DISTRIBUTION CLASS ENCLOSED SINGLE-POLE AIR SWITCHES
    IEEE C37.48.1-2002 GUIDE FOR THE APPLICATION, OPERATION, AND COORDINATION OF HIGH-VOLTAGE (>1000 V) CURRENT-LIMITING FUSES
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective