• IEEE C37.48-2005

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    IEEE Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories

    Available format(s):  PDF

    Superseded date:  31-08-2020

    Language(s):  English

    Published date:  20-05-2005

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Overview
      1.1 Scope
      1.2 Background
      1.3 Description of fuse-enclosure packages (FEPs) using
           expulsion-type indoor power class fuses
      1.4 Description of FEPs using current-limiting type indoor
           distribution and power class fuses
    2 References
    3 Abbreviations
    4 General application guidelines for all fuse types
      4.1 Introduction
      4.2 Service conditions
      4.3 Selection of class and type of fuse
      4.4 Clearances and spacing
      4.5 Fuse position
      4.6 Noise level
      4.7 Selection of fuse voltage rating
      4.8 Selection of continuous current rating (all applications
           except capacitor fuses and fuses used in enclosures)
      4.9 Selection of interrupting rating
      4.10 Fuse-to-fuse coordination procedure
      4.11 Coordination for motor starter fuses (motor protection)
      4.12 Effects of ambient temperature on a fuse
    5 Additional application guidelines for specific devices
      5.1 Current-limiting fuses
      5.2 Current-limiting fuses used in fuse enclosure packages
      5.3 Expulsion fuses in enclosures
      5.4 External fuses for shunt capacitors
    6 Operation guidelines for various fuse types
      6.1 Use of nonexpendable cap on expendable-cap cutouts
      6.2 Operating speed
      6.3 Locking or latching of fuses, blades, or links in closed
           position
      6.4 Fuseholder position
      6.5 Voltage withstand of blown fuses
      6.6 Replacement and handling of fuses
      6.7 Replacement of exhaust control device
      6.8 Operation of energized fuses
      6.9 Storing spare fuse units and replaceable parts
    7 Additional operation guidelines for specific devices
      7.1 Capacitor
      7.2 Liquid-submerged expulsion fuses in enclosures
    8 Maintenance for all fuse types
      8.1 Safety precautions
      8.2 Frequency of maintenance
      8.3 Inspection of fuse or switching device
      8.4 Inspection of fuse links in distribution cutouts
    9 Additional maintenance guidelines for specific devices
      9.1 Capacitor fuses
      9.2 Liquid-submerged expulsion fuses in enclosures
    Annex A (informative) Bibliography

    Abstract - (Show below) - (Hide below)

    Describes information on the application, operation, and maintenance of high-voltage fuses (above 1000 V), distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories for use on ac distribution systems. Devices with rated maximum voltages to 169 kV are covered.

    General Product Information - (Show below) - (Hide below)

    Committee Switchgear
    Development Note Supersedes IEEE DRAFT C37.48. (11/1999)
    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
    IEEE C37.73-1998 IEEE Standard Requirements for Pad-Mounted Fused Switchgear
    IEEE DRAFT 1036 : D13A 2006 APPLICATION OF SHUNT POWER CAPACITORS
    IEEE DRAFT C37.48.1 : D13 2000 DRAFT GUIDE FOR THE OPERATION, CLASSIFICATION, APPLICATION AND COORDINATION OF CURRENT-LIMITING FUSES WITH RATED VOLTAGES 1-38 KV
    IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
    IEEE DRAFT C37.99 : D6 99 DRAFT GUIDE FOR THE PROTECTION OF SHUNT CAPACITOR BANKS
    IEEE C37.48.1-2002 IEEE Guide for the Operation, Classification, Application, and Coordination of Current-Limiting Fuses with Rated Voltages 1-38kV
    UFC 3-550-07 : 2017 UNIFIED FACILITIES CRITERIA - OPERATION AND MAINTENANCE (O&M;): EXTERIOR POWER DISTRIBUTION SYSTEMS
    TM 5-811-1 : V19950228 ARMY TECHNICAL MANUAL - ELECTRICAL POWER SUPPLY AND DISTRIBUTION
    MIL-DTL-917 Revision F:2014 ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR
    IEEE C37.42-2009 SWITCHGEAR DISTRIBUTION CUTOUTS AND FUSE LINKS SPECIFICATIONS
    IEEE C37.45-2007 IEEE Standard Specifications for High Voltage Distribution Class Enclosed Single-Pole Air Switches with Rated Voltages from 1 through 8.3 kV
    IEEE C37.59-2007 IEEE Standard Requirements for Conversion of Power Switchgear Equipment
    IEC TR 62655:2013 Tutorial and application guide for high-voltage fuses
    NEMA SG 2 : 1993 HIGH VOLTAGE FUSES
    IEEE DRAFT C37.20.4 : 2001 DRAFT STANDARD FOR INDOOR AC SWITCHES RATED ABOVE 1KV THROUGH 38KV FOR USE IN METAL-ENCLOSED SWITCHGEAR
    IEEE C37.47-2011 IEEE Standard Specifications for High-Voltage (>1000 V) Distribution Class Current-Limiting Type Fuses and Fuse Disconnecting Switches
    IEEE C37.46-2010 IEEE Standard Specifications for High-Voltage (>1000 V) Expulsion and Current-Limiting Power Class Fuses and Fuse Disconnecting Switches
    IEEE 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)
    IEEE 1531-2003 IEEE Guide for Application and Specification of Harmonic Filters
    PD IEC/TR 62655:2013 Tutorial and application guide for high-voltage fuses
    IEEE DRAFT 1313.2 : D6 DEC 98 DRAFT GUIDE FOR THE APPLICATION OF INSULATED COORDINATION
    IEEE C37.74-2014 REDLINE IEEE Standard Requirements for Subsurface, Vault, and Padmounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems up to 38 kV
    IEEE C37.42-2009 IEEE Standard Specifications for High-Voltage (> 1000 V) Expulsion-Type Distribution-Class Fuses, Fuse and Disconnecting Cutouts, Fuse Disconnecting Switches, and Fuse Links, and Accessories Used with These Devices
    IEEE C37.43-2008 IEEE Standard Specifications for High-Voltage Expulsion, Current-Limiting, and Combination-Type Distribution and Power Class External Fuses, with Rated Voltages from 1 kV through 38 kV, Used for the Protection of Shunt Capacitors
    IEEE C37.46-2010 FOR HIGH VOLTAGE EXPULSION AND CURRENT-LIMITING TYPE POWER CLASS FUSES AND FUSE DISCONNECTING SWITCHES
    IEEE 1036-2010 IEEE Guide for the Application of Shunt Power Capacitors
    IEEE C37.99-2012 IEEE Guide for the Protection of Shunt Capacitor Banks
    IEEE C37.95-2014 IEEE Guide for Protective Relaying of Utility-Consumer Interconnections
    IEEE C37.41-2008 REDLINE IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
    IEEE C37.20.3-2013 REDLINE IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV)
    IEEE C37.20.9-2019 IEEE Standard for Metal-Enclosed Switchgear Rated 1 kV to 52 kV Incorporating Gas Insulating Systems
    IEEE C37.42-2016 REDLINE IEEE Standard Specifications for High-Voltage (>1000 V) Fuses and Accessories
    IEEE C37.48.1-2011 REDLINE IEEE Guide for the Application, Operation, and Coordination of High-Voltage (>1000 V) Current-Limiting Fuses

    Standards Referencing This Book - (Show below) - (Hide below)

    IEEE C62.92.2-1989 IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part II - Grounding of Synchronous Generator Systems
    IEEE C37.46-2010 FOR HIGH VOLTAGE EXPULSION AND CURRENT-LIMITING TYPE POWER CLASS FUSES AND FUSE DISCONNECTING SWITCHES
    IEEE 18-2002 IEEE Standard for Shunt Power Capacitors
    IEEE C37.42-2009 SWITCHGEAR DISTRIBUTION CUTOUTS AND FUSE LINKS SPECIFICATIONS
    IEEE C37.92-2005 IEEE Standard for Analog Inputs to Protective Relays From Electronic Voltage and Current Transducers
    IEC 60282-1:2009+AMD1:2014 CSV High-voltage fuses - Part 1: Current-limiting fuses
    IEEE C37.99-2000 IEEE Guide for the Protection of Shunt Capacitor Banks
    IEEE 1036-2010 IEEE Guide for the Application of Shunt Power Capacitors
    NEMA CP 1:2000 (R2008) SHUNT CAPACITORS
    IEEE C62.92.4-2014 REDLINE IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems--Part IV: Distribution
    IEEE C37.99-2012 IEEE Guide for the Protection of Shunt Capacitor Banks
    IEEE C37.45-2007 SPECIFICATIONS FOR DISTRIBUTION ENCLOSED SINGLE-POLE AIR SWITCHES
    IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
    NFPA 70E : 2018 ELECTRICAL SAFETY IN THE WORKPLACE
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    IEEE C37.41-2008 REDLINE IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
    IEEE C37.41-2000 IEEE Standard Design Tests For High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
    IEEE 18-2012 IEEE Standard for Shunt Power Capacitors
    IEEE C37.48.1-2002 IEEE Guide for the Operation, Classification, Application, and Coordination of Current-Limiting Fuses with Rated Voltages 1-38kV
    IEC 60282-2:2008 High-voltage fuses - Part 2: Expulsion fuses
    IEEE C37.47-2011 DISTRIBUTION FUSE DISCONNECTING SWITCHES, FUSE SUPPORTS, AND CURRENT LIMITING FUSES, SPECIFICATIONS FOR (INCLUDES SUPPLEMENT ANSI C37.47A 1983),
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective