• IEEE DRAFT 1202 : 0

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    FLAME-PROPAGATION TESTING OF WIRE AND CABLE

    Available format(s):  Hardcopy, PDF

    Superseded date:  23-07-2013

    Language(s):  English

    Published date: 

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    Participants
    Contents
    1 Overview
      1.1 Scope
      1.2 Purpose
      1.3 Applications
      1.4 Disclaimer
      1.5 Test Precautions
    2 References
    3 Definitions
    4 Flame Test Facility
      4.1 Enclosure
          4.1.1 Enclosure Walls
          4.1.2 Windows
          4.1.3 Air Intakes
          4.1.4 Access Door
          4.1.5 Exhaust Hood
          4.1.6 Collection Box
      4.2 Exhaust Duct
      4.3 Air Movement with in the Enclosure
      4.4 Cable Tray
      4.5 Burner and Mixer
      4.6 Flowmeters
      4.7 Supply Air
      4.8 Propane
    5 Test Sample Requirements
      5.1 Cable Samples
      5.2 Test Required
    6 Flame Test Procedure
      6.1 Cable Mounting
          6.1.1 Cables Smaller Than 13 mm (0.51 in)
          6.1.2 Cables 13 mm (0.51 in) and Larger
          6.1.3 Flat Cables
      6.2 Test Procedure
          6.2.1 Cables and Cable Tray
          6.2.2 Exhaust Duct Flow Rate
          6.2.3 Burner
          6.2.4 Air Flow & Air Temperature
          6.2.5 Test Duration
          6.2.6 Supplemental Information
    7 Test Evaluation
      7.1 Evaluation of Damage
          7.1.1 Cable Char Damage
          7.1.2 Non-Char Cable Damage
      7.2 Performance Criteria
      7.3 Test Report
    Annex A - Burner &Mixer Information
    Annex B - Bibliography

    Abstract - (Show below) - (Hide below)

    Presents a protocol for exposing cable samples to a theoretical 20 kW (70,000 Btu/hr) flaming ignition source for 20-minute test duration. The test determines the flame propagation tendency of single conductor and multi-conductor cables intended for use in cable trays.

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Document Type Draft
    Publisher Institute of Electrical & Electronics Engineers
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    C22.2 NO. 126.1-17 Metal cable tray systems (Binational standard with NEMA VE 1-2017)
    IEC 60332-3-10:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective