• IEEE DRAFT 404 : D13 2006

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    EXTRUDED AND LAMINATED DIELECTRIC SHIELDED CABLE JOINTS RATED 2500 V - 500 000 V

    Available format(s): 

    Withdrawn date:  17-10-2023

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Institute of Electrical & Electronics Engineers

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative References
    3 Definitions
      3.1 Cable joint categories
      3.2 Joint constructions
      3.3 Other terms
    4 Service conditions
    5 Ratings
      5.1 Voltage
      5.2 Current and Temperature
    6 Construction
      6.1 Identification
      6.2 Shielding
      6.3 Sheath/shield sectional
    7 Testing
      7.1 Production tests for premolded and single-component
           cold-shrink joints
      7.2 Fingerprint tests for heat-shrink and multi-component
           cold-shrink joint components
      7.3 Fingerprint tests for elastomeric taped-joint components
      7.4 Design tests and testing sequence for all joint types
      7.5 Design test conditions
      7.6 Dielectric integrity tests
      7.7 Voltage Withstand tests
      7.8 Short-time current test
      7.9 Cyclic aging test for extruded dielectric and transition
           joints
      7.10 High-voltage time test
      7.11 Sectionalizer tests
      7.12 Semiconducting shielding test
      7.13 Cable metallic-shield restoration and cable jacket
           restoration components
      7.14 Connector thermal and mechanical tests
    Annexes
    Annex A: (Informative) Typical values of heat-shrinkable and
             multi-component cold-shrink joint component tests
             and sampling rates
    Annex B: (Informative) Typical values of elastomeric taped-joint
             component tests and sampling rates
    Annex C: (Informative) Bibliography

    Abstract - (Show below) - (Hide below)

    Lays down electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cables rated in preferred voltage steps from 2500 V to 500 000 V. In addition, it defines test requirements for cable jacket and cable shield restoration devices.

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Document Type Draft
    Publisher Institute of Electrical & Electronics Engineers
    Status Withdrawn
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM D 4325 : 2013 : REDLINE Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes
    ASTM D 4496 : 2013 Standard Test Method for D-C Resistance or Conductance of Moderately Conductive Materials
    ASTM D 4388 : 2013 Standard Specification for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes
    IEC 60502-4:2010 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
    IEEE 592-2007 REDLINE IEEE Standard for Exposed Semiconducting Shields on High-Voltage Cable Joints and Separable Connectors
    WC 5-1992 THERMOPLASTIC-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
    IEEE 82 : 2002 TEST PROCEDURE FOR IMPULSE VOLTAGE TESTS ON INSULATED CONDUCTORS
    WC 8:1988 ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
    ICEA P 32 382 : 2007(R2018) SHORT CIRCUIT CHARACTERISTICS OF INSULATED CABLES
    WC 4-1988/ICEA S-65-375 3rd Ed. (R1993) VARNISHED-CLOTH-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
    IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
    ICEA S 94 649 : 2013 CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV
    IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
    WC 3-1992 RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
    ICEA S 97 682 : 2013 UTILITY SHIELDED POWER CABLES RATED 5 THROUGH 46 KV
    IEEE 575-2014 IEEE Guide for Bonding Shields and Sheaths of Single-Conductor Power Cables Rated 5 kV through 500 kV
    WC 7-1988 CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective