DRAFT STANDARD TEST CODE FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS
21-10-2023
12-01-2013
1 Overview
1.1 Scope
1.2 Purpose
1.3 Word usage
2 References
3 Definitions
4 General
4.1 Test definitions
4.2 Test requirements
4.3 Test sequence
4.4 Instrumentation
5 Resistance measurements
5.1 General
5.2 Determination of cold temperature
5.3 Conversion of resistance measurements
5.4 Resistance measurement methods
6 Polarity and phase-relation tests
6.1 Subtractive and additive polarity
6.2 Polarity tests - Single-phase transformers
6.3 Polarity and phase-relation tests - Polyphase
transformers
7 Ratio tests
7.1 General
7.2 Tolerances for ratio
7.3 Ratio test methods
8 No-load losses and excitation current
8.1 General
8.2 No-load loss test
8.3 Waveform correction of no-load losses
8.4 Determination of excitation (no-load) current
9 Load losses and impedance voltage
9.1 General
9.2 Factors affecting the values of load losses and
impedance voltage
9.3 Tests for measuring load losses and impedance
voltage
9.4 Calculation of load losses and impedance voltage
from test data
9.5 Zero-phase-sequence impedance
10 Dielectric tests
10.1 Factory dielectric tests
10.2 Dielectric tests in the field
10.3 Applied-Voltage tests
10.4 Induced-voltage tests
10.5 Impulse tests
10.6 Impulse tests on transformer neutrals
10.7 Detection of failure during impulse test
10.8 Insulation-power-factor tests
10.9 Insulation-resistance tests
10.10 partial discharge tests
11 Temperature test
11.1 General
11.2 Ambient temperature measurements
11.3 Surface temperature measurements
11.4 Cold-resistance measurements
11.5 Hot-resistance measurement
11.6 Calculation of average winding temperature rise
11.7 Correction factors
11.8 Temperature rise test loading methods
12 Short-circuit tests
12.1 Scope
12.2 Short-circuit testing techniques
12.3 Test requirements
12.4 Test procedure
12.5 Failure detection techniques
12.6 Analysis of test results and visual inspection
12.7 Proof of satisfactory performance
12.8 Required information for transformer short-
circuit test reports
13 Audible sound-level measurements
13.1 General
13.2 Instrumentation
13.3 Test conditions
13.4 Microphone positions
13.5 Sound level measurements
13.6 Optional-frequency analysis measurements
14 Mechanical design tests
14.1 Components involved in lifting or moving
14.2 Tests of sealed dry-type transformers
15 Calculated data
15.1 Reference temperature
15.2 Total losses
15.3 Efficiency
15.4 Voltage regulation
16 Minimum information to be included in certified test
data
16.1 Order data
16.2 Rating data
16.3 Test data
16.4 Calculated data
16.5 Certification statement and approval
Annex A - Bibliography
Describes methods for performing tests specified in IEEE Std C57.12.01-1989 and other referenced standards applicable to dry-type distribution and power transformers. It is meant for use as a basis for performance, safety and the proper testing of dry-type distribution and power transformers.
DocumentType |
Draft
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Withdrawn
|
SupersededBy |
IEEE C57.12.51-2008 | REQUIREMENTS FOR SEALED DRY-TYPE POWER TRANSFORMERS, 501 KVA AND LARGER, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 208Y/120 TO 4160 VOLTS |
IEEE 99-2007 REDLINE | IEEE Recommended Practice for the Preparation of Test Procedures for the Thermal Evaluation of Insulation Systems for Electrical Equipment |
IEEE C57.12.59-2015 | IEEE Guide for Dry-Type Transformer Through-Fault Current Duration |
IEEE C57.12.01-2015 REDLINE | IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers |
IEEE C57.134-2013 | IEEE Guide for Determination of Hottest-Spot Temperature in Dry-Type Transformers |
ANSI S1.4 : 1983 | SPECIFICATION FOR SOUND LEVEL METERS |
ANSI S1.11 : 2014 | SPECIFICATION FOR OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND ANALOG AND DIGITAL FILTERS |
IEEE C57.12.60-2009 REDLINE | IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers, Including Open-Wound, Solid-Cast, and Resin-Encapsulated Transformers |
IEEE C57.12.58-1991 | IEEE Guide for Conducting a Transient Voltage Analysis of a Dry-Type Transformer Coil |
IEEE C57.96-2013 | IEEE Guide for Loading Dry-Type Distribution and Power Transformers |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEEE C57.124 : 1991 | RECOMMENDED PRACTICE FOR THE DETECTION OF PARTIAL DISCHARGE AND THE MEASUREMENT OF APPARENT CHARGE IN DRY-TYPE TRANSFORMERS |
ANSI C57.12.52 : 2012 | Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements |
IEEE C57.98-2011 | IEEE Guide for Transformer Impulse Tests |
IEEE C57.12.70-2011 | IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers |
IEEE C57.12.50 : 1981 | REQUIREMENTS FOR VENTILATED DRY-TYPE DISTRIBUTION TRANSFORMERS, 1 TO 500 KVA, SINGLE-PHASE, AND 15 TO 500 KVA, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 120 TO 600 VOLTS |
IEEE C57.12.56-1986 | IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Ventilated Dry-Type Power and Distribution Transformers |
ANSI C57.12.57 : 1987 | AMERICAN NATIONAL STANDARD FOR TRANSFORMERS - VENTILATED DRY-TYPE NETWORK TRANSFORMERS 2500 KVA AND BELOW, THREE-PHASE, WITH HIGH-VOLTAGE 34500 VOLTS AND BELOW, LOW-VOLTAGE 216Y/125 AND 480Y/227 VOLTS - REQUIREMENTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.