• IEEE C57.12.50 : 1981

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    REQUIREMENTS FOR VENTILATED DRY-TYPE DISTRIBUTION TRANSFORMERS, 1 TO 500 KVA, SINGLE-PHASE, AND 15 TO 500 KVA, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 120 TO 600 VOLTS

    Available format(s): 

    Withdrawn date:  17-10-2023

    Language(s): 

    Published date:  01-01-1981

    Publisher:  Institute of Electrical & Electronics Engineers

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. Scope
        1.1
        1.2
        1.3
        1.4
        1.5
    2. Related Standards and Guides
        2.1 General
        2.2 Terminology
        2.3 Revision of American National Standards Referred
             to in This Document
    Part I: Basic Electrical and Mechanical Requirements
    3. Usual Service Conditions
    4. Ratings and Characteristics
        4.1 Kilovolt-Ampere Ratings
        4.2 Kilovolt-Ampere and Voltage Ratings
        4.3 Taps
        4.4 Insulation Levels
        4.5 Polarity, Angular Displacement, and Terminal
             Markings
        4.6 Impedance Voltage
    5. Construction
        5.1 Insulation System
        5.2 Accessory Location
        5.3 Nameplate
        5.4 Transformer Connections
        5.5 Tap Changing
        5.6 Lifting Facilities and Stability
        5.7 Grounding Facilities
        5.8 Transformer Enclosure
    6. Routine Tests
    7. Tolerances
    Part II: Other Requirements or Alternatives That May Be
             Specified for Some Applications
    8. Other Ratings and Characteristics
        8.1 Other Kilovolt-Ampere Ratings
        8.2 40 degree C Average Ambient Temperature
             Conditions
        8.3 Other Winding Temperature Rises
        8.4 Other Insulation Systems
        8.5 Other High-Voltage Ratings and Connections
        8.6 Y-Y Connected Transformers
        8.7 Increased Neutral Insulation
        8.8 Other Basic Lightning impulse Insulation Levels
             (BILs)
    9. Other Construction
        9.1 High-Voltage Connection Arrangements
        9.2 Low-Voltage Connection Arrangements
        9.3 Surge Arresters
        9.4 Unit Substation
        9.5 Temperature Devices
        9.6 Forced-Air Cooling
        9.7 Provision for Future Forced-Air Cooling
        9.8 Space Heaters
        9.9 Current Transformers (or Provision for Their
             Addition in the Future)
        9.10 Terminal Blocks
        9.11 Contacts
        9.12 Jacking and Moving Facilities
    10. Other Tests

    Abstract - (Show below) - (Hide below)

    Defines characteristics relating to performance, limited mechanical and electrical interchangeability, and safety of the equipment described, and to assist in the proper selection of such equipment.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE C57.94-1982 IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type General Purpose Distribution and Power Transformers
    IEEE C57.12.51-2008 IEEE Standard for Ventilated Dry- Type Power Transformers, 501 kVA and Larger, Three-Phase, with High- Voltage 601 V to 34 500 V; Low- Voltage 208Y/120 V to 4160 V- General Requirements
    IEEE DRAFT C57.12.91 : D3 2000 DRAFT STANDARD TEST CODE FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS
    ANSI C57.12.52 : 2012 Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements
    NEMA TR1 : 2013 TRANSFORMERS, STEP VOLTAGE REGULATORS AND REACTORS
    IEEE DRAFT C57.12.01 : D6 2005 GENERAL REQUIREMENTS FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS INCLUDING THOSE WITH SOLID-CAST AND/OR RESIN ENCAPSULATED WINDINGS
    ANSI C57.12.57 : 1987 AMERICAN NATIONAL STANDARD FOR TRANSFORMERS - VENTILATED DRY-TYPE NETWORK TRANSFORMERS 2500 KVA AND BELOW, THREE-PHASE, WITH HIGH-VOLTAGE 34500 VOLTS AND BELOW, LOW-VOLTAGE 216Y/125 AND 480Y/227 VOLTS - REQUIREMENTS
    IEEE C37.121-2012 GUIDE FOR SWITCHGEAR - UNIT SUBSTATION - REQUIREMENTS
    IEEE C57.12.52-2012 IEEE Standard for Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements
    IEEE C57.12.91-2011 IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
    IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers
    IEEE C57.12.56-1986 IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Ventilated Dry-Type Power and Distribution Transformers
    IEEE C37.121-2012 REDLINE IEEE Guide for Switchgear - Unit Substation - Requirements

    Standards Referencing This Book - (Show below) - (Hide below)

    IEEE C57.12.51-2008 REQUIREMENTS FOR SEALED DRY-TYPE POWER TRANSFORMERS, 501 KVA AND LARGER, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 208Y/120 TO 4160 VOLTS
    IEEE C57.12.01-2015 REDLINE IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers
    ANSI C57.12.52 : 2012 Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements
    ANSI C84.1 : 2016 ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ)
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers
    IEEE C57.12.91-2011 IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
    IEEE C57.94-1982 IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type General Purpose Distribution and Power Transformers
    IEEE C57.105-1978 IEEE Guide for Application of Transformer Connections in Three-Phase Distribution Systems
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective