• IEEE DRAFT C57.12.91 : D3 2000

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    DRAFT STANDARD TEST CODE FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS

    Available format(s): 

    Withdrawn date:  21-10-2023

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Institute of Electrical & Electronics Engineers

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Overview
          1.1 Scope
          1.2 Purpose
          1.3 Word usage
    2 References
    3 Definitions
    4 General
          4.1 Test definitions
          4.2 Test requirements
          4.3 Test sequence
          4.4 Instrumentation
    5 Resistance measurements
          5.1 General
          5.2 Determination of cold temperature
          5.3 Conversion of resistance measurements
          5.4 Resistance measurement methods
    6 Polarity and phase-relation tests
          6.1 Subtractive and additive polarity
          6.2 Polarity tests - Single-phase transformers
          6.3 Polarity and phase-relation tests - Polyphase
                 transformers
    7 Ratio tests
          7.1 General
          7.2 Tolerances for ratio
          7.3 Ratio test methods
    8 No-load losses and excitation current
          8.1 General
          8.2 No-load loss test
          8.3 Waveform correction of no-load losses
          8.4 Determination of excitation (no-load) current
    9 Load losses and impedance voltage
          9.1 General
          9.2 Factors affecting the values of load losses and
                 impedance voltage
          9.3 Tests for measuring load losses and impedance
                 voltage
          9.4 Calculation of load losses and impedance voltage
                 from test data
          9.5 Zero-phase-sequence impedance
    10 Dielectric tests
          10.1 Factory dielectric tests
          10.2 Dielectric tests in the field
          10.3 Applied-Voltage tests
          10.4 Induced-voltage tests
          10.5 Impulse tests
          10.6 Impulse tests on transformer neutrals
          10.7 Detection of failure during impulse test
          10.8 Insulation-power-factor tests
          10.9 Insulation-resistance tests
          10.10 partial discharge tests
    11 Temperature test
          11.1 General
          11.2 Ambient temperature measurements
          11.3 Surface temperature measurements
          11.4 Cold-resistance measurements
          11.5 Hot-resistance measurement
          11.6 Calculation of average winding temperature rise
          11.7 Correction factors
          11.8 Temperature rise test loading methods
    12 Short-circuit tests
          12.1 Scope
          12.2 Short-circuit testing techniques
          12.3 Test requirements
          12.4 Test procedure
          12.5 Failure detection techniques
          12.6 Analysis of test results and visual inspection
          12.7 Proof of satisfactory performance
          12.8 Required information for transformer short-
                 circuit test reports
    13 Audible sound-level measurements
          13.1 General
          13.2 Instrumentation
          13.3 Test conditions
          13.4 Microphone positions
          13.5 Sound level measurements
          13.6 Optional-frequency analysis measurements
    14 Mechanical design tests
          14.1 Components involved in lifting or moving
          14.2 Tests of sealed dry-type transformers
    15 Calculated data
          15.1 Reference temperature
          15.2 Total losses
          15.3 Efficiency
          15.4 Voltage regulation
    16 Minimum information to be included in certified test
          data
          16.1 Order data
          16.2 Rating data
          16.3 Test data
          16.4 Calculated data
          16.5 Certification statement and approval
    Annex A - Bibliography

    Abstract - (Show below) - (Hide below)

    Describes methods for performing tests specified in IEEE Std C57.12.01-1989 and other referenced standards applicable to dry-type distribution and power transformers. It is meant for use as a basis for performance, safety and the proper testing of dry-type distribution and power transformers.

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Document Type Draft
    Publisher Institute of Electrical & Electronics Engineers
    Status Withdrawn
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    IEEE C57.12.51-2008 REQUIREMENTS FOR SEALED DRY-TYPE POWER TRANSFORMERS, 501 KVA AND LARGER, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 208Y/120 TO 4160 VOLTS
    IEEE 99-2007 REDLINE IEEE Recommended Practice for the Preparation of Test Procedures for the Thermal Evaluation of Insulation Systems for Electrical Equipment
    IEEE C57.12.59-2015 IEEE Guide for Dry-Type Transformer Through-Fault Current Duration
    IEEE C57.12.01-2015 REDLINE IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers
    IEEE C57.134-2013 IEEE Guide for Determination of Hottest-Spot Temperature in Dry-Type Transformers
    ANSI S1.4 : 1983 SPECIFICATION FOR SOUND LEVEL METERS
    ANSI S1.11 : 2014 SPECIFICATION FOR OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND ANALOG AND DIGITAL FILTERS
    IEEE C57.12.60-2009 REDLINE IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers, Including Open-Wound, Solid-Cast, and Resin-Encapsulated Transformers
    IEEE C57.12.58-1991 IEEE Guide for Conducting a Transient Voltage Analysis of a Dry-Type Transformer Coil
    IEEE C57.96-2013 IEEE Guide for Loading Dry-Type Distribution and Power Transformers
    IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
    IEEE C57.124 : 1991 RECOMMENDED PRACTICE FOR THE DETECTION OF PARTIAL DISCHARGE AND THE MEASUREMENT OF APPARENT CHARGE IN DRY-TYPE TRANSFORMERS
    ANSI C57.12.52 : 2012 Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements
    IEEE C57.98-2011 IEEE Guide for Transformer Impulse Tests
    IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers
    IEEE C57.12.50 : 1981 REQUIREMENTS FOR VENTILATED DRY-TYPE DISTRIBUTION TRANSFORMERS, 1 TO 500 KVA, SINGLE-PHASE, AND 15 TO 500 KVA, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 120 TO 600 VOLTS
    IEEE C57.12.56-1986 IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Ventilated Dry-Type Power and Distribution Transformers
    ANSI C57.12.57 : 1987 AMERICAN NATIONAL STANDARD FOR TRANSFORMERS - VENTILATED DRY-TYPE NETWORK TRANSFORMERS 2500 KVA AND BELOW, THREE-PHASE, WITH HIGH-VOLTAGE 34500 VOLTS AND BELOW, LOW-VOLTAGE 216Y/125 AND 480Y/227 VOLTS - REQUIREMENTS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective