ISA 12.00.01 : 2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 0, 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS
Hardcopy , PDF
15-08-2005
English
01-01-2002
General Notes
Preface (ISA)
Foreword (UL)
National Differences
Foreword (ISA)
1 Scope
2 References
3 Definitions and symbols
4 Apparatus grouping and temperature classification
5 Temperatures
6 General
7 Non-metallic enclosures and non-metallic parts of
enclosures
8 Enclosures containing light metals
9 Fasteners
10 Interlocking devices
11 Bushings
12 Materials used for cementing
13 Ex-components
14 Connection facilities and terminal compartments
15 Connection facilities for earthing or bonding
conductors
16 Cable and conduit entries
17 Rotating electrical machines
18 Supplementary requirements for switchgear
19 Supplementary requirements for fuses
20 Supplementary requirements for plugs and sockets
21 Supplementary requirements for luminaries
22 Supplementary requirements for caplights, caplamps and
handlamps
23 Type verifications and tests
24 Routine verifications and tests
25 Manufacturer's responsibility
26 Verifications and tests on modified or repaired
electrical apparatus
27 Marking
Annex A (informative) - Subdivision of gases and vapours
according to their maximum experimental
safe gaps and minimum ignition currents
Annex B (normative) - Ex-cable entries (glands or fittings)
Annex C (normative) - Ex-components
Annex D (informative) - Example of rig for resistance to
impact test
Annex E (informative) - Common standards - safety requirements
for electrical equipment
Annex F (informative) - United States Major Deviations
Annex G (informative) - Equipment grounding
Annex H (informative) - Editorial differences between
ANSI/UL 60079-0 and ANSI/ISA-12.00.01-
(IEC 60079-0 Mod)
Annex I (informative) - National differences types noted
in ANSI/UL 60079-0
Gives general testing, construction and marking requirements of electrical apparatus, Ex cable entries and Ex components, used in explosive environments of vapor, gas and mist specified as Class 1, Zone 0, 1 and 2 by National Electrical Code NFPA 70.
Committee |
SP12
|
DevelopmentNote |
Formerly it was ISA-S12.00.01 (05/2001) Also numbered as UL 60079-0. (09/2003) Renumbered as ISA 60079-0 (09/2005)
|
DocumentType |
Standard
|
Pages |
116
|
PublisherName |
International Society of Automation
|
Status |
Superseded
|
SupersededBy |
ISA 12.13.01 : 2003 | PERFORMANCE REQUIREMENTS FOR COMBUSTIBLE GAS DETECTORS |
ISA 12.02.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONES 0, 1 & 2 HAZARDOUS (CLASSIFIED) LOCATIONS - INTRINSIC SAFETY |
CSA PLUS 2203 : 2001 | HAZARDOUS LOCATIONS - GUIDE FOR THE DESIGN, TESTING, CONSTRUCTION, AND INSTALLATION OF EQUIPMENT IN EXPLOSIVE ATMOSPHERES |
ISA TR12.21.01 : 2004 | USE OF FIBER OPTIC SYSTEMS IN CLASS 1 HAZARDOUS (CLASSIFIED) LOCATIONS |
ISA 12.26.01 : 1998 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - OIL IMMERSION "O" |
ISA 12.23.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - ENCAPSULATION "M" |
ISA 12.16.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - INCREASED SAFETY |
ISA 12.26.01 : 1998 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - OIL IMMERSION "O" |
ISA 12.25.01 : 1998 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - POWDER FILLING "Q" |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60192:2001 | Low-pressure sodium vapour lamps - Performance specifications |
IEC TR 60079-20:1996 | Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus |
ISA 12.12.01 : 2007 | NONINCENDIVE ELECTRICAL EQUIPMENT FOR USE IN CLASS 1 AND 2, DIVISION 2 AND CLASS 3, DIVISIONS 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS |
ISA 12.02.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONES 0, 1 & 2 HAZARDOUS (CLASSIFIED) LOCATIONS - INTRINSIC SAFETY |
NFPA 496 : 2017 | PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT |
ISA RP12.4 : 1996 | PRESSURIZED ENCLOSURES |
IEC 60079-3:1990 | Electrical apparatus for explosive gas atmospheres - Part 3: Spark-test apparatus for intrinsically-safe circuits |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISA 12.23.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - ENCAPSULATION "M" |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
ISA 12.22.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS TYPE OF PROTECTION - FLAMEPROOF "D" |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.