• There are no items in your cart

ISO 15042:2017

Current

Current

The latest, up-to-date edition.

Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

18-07-2017

€206.00
Excluding VAT

ISO 15042:2017 specifies the performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps.

ISO 15042:2017 is applicable to the following equipment:

-― basic multi-split systems, modular multi-split systems and modular heat recovery multi-split systems. These multi-split systems include air-to-air systems with non-ducted and/or ducted indoor units with integral fans and indoor units supplied without fans.

ISO 15042:2017 is limited to:

- residential, commercial and industrial split-system air conditioners and heat pumps;

- factory-made, electrically driven and use mechanical compression;

- single- and multiple-circuit split-systems which utilize one or more compressors with no more than two steps of control of the outdoor unit;

or

- split-systems with a single refrigeration circuit which utilize one or more variable-speed compressors or alternative compressor combinations for varying the capacity of the system by three or more steps.

These split-systems are designed to operate with a combination of one or more outdoor units and two or more indoor units designed for individual operation, and such modular systems are capable of transferring recovered heat from one or more indoor units to other units in the same system.

The requirements of testing and rating contained in this document are based on the use of matched assemblies.

ISO 15042:2017 is not applicable to the rating and testing of the following:

a) water-cooled or water source equipment;

b) mobile (single-duct) units having a condenser exhaust duct;

c) individual assemblies not constituting a complete refrigeration system;

d) equipment using the absorption refrigeration cycle.

e) ducted air conditioners and/or ducted heat pumps, rated at less than 8 kW and intended to operate at external static pressures of less than 25 Pa, controlled by a single thermostat/controller (refer to ISO 5151);

f) multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller (refer to ISO 5151 or ISO 13253).

ISO 15042:2017 does not cover the determination of seasonal efficiencies or seasonal part-load performances, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.

NOTE Throughout this document, the terms "equipment" and "systems" mean "multi-split air conditioners" and/or "multi-split heat pumps".

DevelopmentNote
Supersedes ISO/DIS 15042. (07/2017) NEW CHILD AMD 1 2020 IS ADDED
DocumentType
Standard
Pages
97
ProductNote
NEW CHILD AMD 1 2020 IS ADDED
PublisherName
International Organization for Standardization
Status
Current
Supersedes

Standards Relationship
NEN ISO 15042 : 2017 Identical
BS ISO 15042:2017 Identical

PD CEN ISO/TS 16491:2012 Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests
15/30284307 DC : 0 BS ISO 5151 - NON-DUCTED AIR CONDITIONERS AND HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE
12/30234071 DC : 0 BS ISO 16358-3 - AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 3: ANNUAL PERFORMANCE FACTOR
IEC 60335-2-40:2018 RLV Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers
CEN ISO/TS 16491:2012 Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests (ISO/TS 16491:2012)
12/30234064 DC : 0 BS ISO 16358-1 - AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 1: COOLING SEASONAL PERFORMANCE FACTOR
12/30234068 DC : 0 BS ISO 16358-2 - AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 2: HEATING SEASONAL PERFORMANCE FACTOR
BS ISO 16358-3:2013 Air-cooled air conditioners and air-to-air heat pumps. Testing and calculating methods for seasonal performance factors Annual performance factor
BS ISO 16358-2:2013 Air-cooled air conditioners and air-to-air heat pumps. Testing and calculating methods for seasonal performance factors Heating seasonal performance factor
BS ISO 13253:2017 Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance
BS ISO 5151:2017 Non-ducted air conditioners and heat pumps. Testing and rating for performance
ISO 13253:2017 Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance
ISO 16358-1:2013 Air-cooled air conditioners and air-to-air heat pumps — Testing and calculating methods for seasonal performance factors — Part 1: Cooling seasonal performance factor
IEC 60335-2-40:2018 Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers
ISO 16358-3:2013 Air-cooled air conditioners and air-to-air heat pumps — Testing and calculating methods for seasonal performance factors — Part 3: Annual performance factor
S.R. CEN ISO/TS 16491:2012 GUIDELINES FOR THE EVALUATION OF UNCERTAINTY OF MEASUREMENT IN AIR CONDITIONER AND HEAT PUMP COOLING AND HEATING CAPACITY TESTS (ISO/TS 16491:2012)
BS ISO 16358-1:2013 Air-cooled air conditioners and air-to-air heat pumps. Testing and calculating methods for seasonal performance factors Cooling seasonal performance factor
ISO 5151:2017 Non-ducted air conditioners and heat pumps — Testing and rating for performance
15/30284301 DC : 0 BS ISO 13253 - DUCTED AIR-CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE
ISO 16358-2:2013 Air-cooled air conditioners and air-to-air heat pumps Testing and calculating methods for seasonal performance factors Part 2: Heating seasonal performance factor
ISO/TS 16491:2012 Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests
AHRI 340/360 (I-P) : 2015 PERFORMANCE RATING OF COMMERCIAL AND INDUSTRIAL UNITARY AIR-CONDITIONING AND HEAT PUMP EQUIPMENT

ISO 5151:2017 Non-ducted air conditioners and heat pumps — Testing and rating for performance
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
ISO 13253:2017 Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance
ISO 817:2014 Refrigerants Designation and safety classification
ISO 3966:2008 Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes
ISO/TS 16491:2012 Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.