• ISO 16063-15:2006

    Current The latest, up-to-date edition.

    Methods for the calibration of vibration and shock transducers Part 15: Primary angular vibration calibration by laser interferometry

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  21-07-2006

    Publisher:  International Organization for Standardization

    Add To Cart

    Abstract - (Show below) - (Hide below)

    ISO 16063-15:2006 specifies the instrumentation and procedures used for primary angular vibration calibration of angular transducers, i.e. angular accelerometers, angular velocity transducers and rotational angle transducers (with or without amplifier) to obtain the magnitude and the phase shift of the complex sensitivity by steady-state sinusoidal vibration and laser interferometry. The methods specified in ISO 16063-15:2006 are applicable to measuring instruments (rotational laser vibrometers in particular) and to angular transducers as defined in ISO 2041 for the quantities of rotational angle, angular velocity and angular acceleration.

    ISO 16063-15:2006 is applicable to a frequency range from 1 Hz to 1,6 kHz and a dynamic range (amplitude) from 0,1 rad/s2 to 1 000 rad/s2 (frequency-dependent). Calibration frequencies lower than 1 Hz (e.g. 0,4 Hz, which is a reference frequency used in other International Standards) and angular acceleration amplitudes smaller than 0,1 rad/s2 can be achieved using method 3A or method 3B specified in ISO 16063-15:2006, in conjunction with an appropriate low-frequency angular vibration generator.

    ISO 16063-15:2006 describes six methods. Method 1A ( fringe-counting, interferometer type A) and method 1B ( fringe-counting, interferometer type B) are applicable to the calibration of the magnitude of complex sensitivity in the frequency range of 1 Hz to 800 Hz and under special conditions, at higher frequencies. Method 2A (minimum-point method, interferometer type A) and method 2B (minimum-point method, interferometer type B) can be used for sensitivity magnitude calibration in the frequency range of 800 Hz to 1,6 kHz. Method 3A (sine-approximation method, interferometer type A) and method 3B (sine-approximation method, interferometer type B) can be used for magnitude of sensitivity and phase calibration in the frequency range of 1 Hz to 1,6 kHz. Methods 1A, 1B and 3A, 3B provide for calibrations at fixed angular acceleration amplitudes at various frequencies. Methods 2A and 2B require calibrations at fixed rotational angle amplitudes (angular velocity amplitude and angular acceleration amplitude vary with frequency).

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes ISO/DIS 16063-15 (07/2006)
    Document Type Standard
    Publisher International Organization for Standardization
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    DKD-R 3-1-1 : 2010 KALIBRIERUNG VON BESCHLEUNIGUNGSMESSGERAETEN NACH DEM VERGLEICHSVERFAHREN - BLATT 1: GRUNDLAGEN
    EN 62047-20:2014 Semiconductor devices - Micro-electromechanical devices - Part 20: Gyroscopes
    12/30256751 DC : 0 BS EN 62047-20 - SEMICONDUCTOR DEVICES - MICRO-ELECTROMECHANICAL DEVICES - PART 20: GYROSCOPES
    I.S. EN 62047-20:2014 SEMICONDUCTOR DEVICES - MICROELECTROMECHANICAL DEVICES - PART 20: GYROSCOPES
    DKD-R 3-1-3 : 2003 KALIBRIERUNG VON BESCHLEUNIGUNGSMESSGERAETEN NACH DEM VERGLEICHSVERFAHREN - TEIL 3: SINUS- UND MULTISINUS-ANREGUNG
    IEC 62047-20:2014 Semiconductor devices - Micro-electromechanical devices - Part 20: Gyroscopes
    DKD-R 3-1-4 : 2005 KALIBRIERUNG VON BESCHLEUNIGUNGSMESSGERAETEN NACH DEM VERGLEICHSVERFAHREN - BLATT 4: PRIMAERKALIBRIERUNG VON SCHWINGUNGSMESSGERAE-TEN MIT SINUSFOERMIGER ANREGUNG UND INTERFEROMETRISCHER MESSUNG DER SCHWIN-GUNGSGROESSE
    BS ISO 21289:2008 Mechanical vibration and shock. Parameters to be specified for the acquisition of vibration data
    BS EN 62047-20:2014 Semiconductor devices. Micro-electromechanical devices Gyroscopes
    ISO 21289:2008 Mechanical vibration and shock — Parameters to be specified for the acquisition of vibration data

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 266:1997 Acoustics — Preferred frequencies
    ISO 2041:2009 Mechanical vibration, shock and condition monitoring Vocabulary
    ISO 16063-1:1998 Methods for the calibration of vibration and shock transducers Part 1: Basic concepts
    ISO 16063-11:1999 Methods for the calibration of vibration and shock transducers Part 11: Primary vibration calibration by laser interferometry
    ISO 5348:1998 Mechanical vibration and shock Mechanical mounting of accelerometers
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective