ISO 6145-5:2009
Current
The latest, up-to-date edition.
Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 5: Capillary calibration devices
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, French
22-10-2009
ISO 6145-5:2009 is one of a series of International Standards dealing with the various dynamic volumetric techniques used for the preparation of calibration gas mixtures. This part specifies a method for the continuous production of calibration gas mixtures from pure gases or gas mixtures using capillary calibration devices in single or multiple combinations (gas dividers).
Single capillary systems can be used to provide gas mixtures where the minor component is in the range of volume fractions from 10-8 to 0,5.
The relative expanded uncertainty of this technique is less than ±2 % (k = 2) relative. This application is used in industrial gas mixing panels for the production of specific gas atmospheres.
Gas dividers can be used to divide gas mixtures prepared from gases or gas mixtures into controlled proportions by volume. These devices are capable of dilutions in the range of volume fractions from 0,000 5 to 0,9 of the primary gas concentration with a relative repeatability of better than 0,5 %.
Traceability of the gas mixtures produced by a gas divider is achieved by comparison of a mixture with gas mixtures related to national or international gas standards. An example is given in Annex A.
Committee |
ISO/TC 158
|
DevelopmentNote |
Supersedes ISO/DIS 6145-5. (10/2009)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF ISO 6145-5 : 2010 | Identical |
NF EN ISO 6145-5 : 2011 | Identical |
NBN EN ISO 6145-5 : 2011 | Identical |
NEN ISO 6145-5 : 2009 | Identical |
NEN EN ISO 6145-5 : 2011 | Identical |
NS EN ISO 6145-5 : 2010 | Identical |
I.S. EN ISO 6145-5:2010 | Identical |
PN EN ISO 6145-5 : 2012 | Identical |
SAC GB/T 5275-5 : 2014 | Identical |
SN EN ISO 6145-5:2011 | Identical |
UNI EN ISO 6145-5 : 2011 | Identical |
BIS IS 16249-5 : 2014 | Identical |
UNE-EN ISO 6145-5:2011 | Identical |
BS EN ISO 6145-5:2010 | Identical |
EN ISO 6145-5:2010 | Identical |
DIN EN ISO 6145-5:2011-03 | Identical |
BS ISO 6145-5 : 2009 | Identical |
PNE-ISO 6145-5 | Identical |
UNE-ISO 6145-5:2006 | Identical |
NFX 43 044 : 95 XP | AIR QUALITY - AMBIENT AIR - DETERMINATION OF CARBON MONOXIDE (CO) BY INFRARED ABSORPTION GASEOUS FILTERS CORRELATION METHOD |
DIN EN ISO 6145-1:2008-11 | GAS ANALYSIS - PREPARATION OF CALIBRATION GAS MIXTURES USING DYNAMIC VOLUMETRIC METHODS - PART 1: METHODS OF CALIBRATION |
BS EN 13528-3:2003 | Ambient air quality. Diffusive samplers for the determination of concentrations of gases and vapours. Requirements and test methods Guide to selection, use and maintenance |
EN 13528-3:2003 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 3: Guide to selection, use and maintenance |
NIST SP 260-222:2022 | Certification of NIST Gas Mixture Standard Reference Materials |
UNI EN ISO 6145-1 : 2009 | GAS ANALYSIS - PREPARATION OF CALIBRATION GAS MIXTURES USING DYNAMIC VOLUMETRIC METHODS - PART 1: METHODS OF CALIBRATION |
EN 60079-29-1:2016 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
UNE-EN 60079-29-1:2017 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
DIN EN ISO 16017-2:2003-09 | INDOOR, AMBIENT AND WORKPLACE AIR - SAMPLING AND ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY SORBENT TUBE/THERMAL DESORPTION/CAPILLARY GAS CHROMATOGRAPHY - PART 2: DIFFUSIVE SAMPLING |
I.S. EN 14042:2003 | WORKPLACE ATMOSPHERES - GUIDE FOR THE APPLICATION AND USE OF PROCEDURES FOR THE ASSESSMENT OF EXPOSURE TO CHEMICAL AND BIOLOGICAL AGENTS |
VDI 2100 Blatt 3:2011-10 | Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Active sampling by accumulation on adsorbents - Thermal desorption |
04/30112677 DC : 0 | IEC 61779-1 ED.2 - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
BS EN 60079-29-1:2007 | Explosive atmospheres Gas detectors. Performance requirements of detectors for flammable gases |
ISO/TS 14167:2003 | Gas analysis General quality assurance aspects in the use of calibration gas mixtures - Guidelines |
ISO 6145-1:2003 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration |
17/30321967 DC : 0 | BS ISO/IEC 20435-1 - WORKPLACE ATMOSPHERES - PART 1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR TOXIC GASES |
17/30345272 DC : 0 | BS ISO 14167 - GAS ANALYSIS - GENERAL QUALITY ASPECTS AND METROLOGICAL TRACEABILITY OF CALIBRATION GAS MIXTURES |
BS EN ISO 6145-1:2008 | Gas analysis. Preparation of calibration gas mixtures using dynamic volumetric methods Methods of calibration |
BS EN ISO 16017-1:2001 | Indoor, ambient and workplace air. Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Pumped sampling |
BS EN 14042:2003 | Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents |
BS EN ISO 16017-2:2003 | Indoor, ambient and workplace air. Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Diffusive sampling |
EN ISO 6145-1:2008 | Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 1: Methods of calibration (ISO 6145-1:2003) |
EN ISO 16017-2:2003 | Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ISO 16017-2:2003) |
EN ISO 16017-1:2000 | Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling (ISO 16017-1:2000) |
EN 14042:2003 | Workplace atmospheres - Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents |
13/30267536 DC : 0 | BS EN 60079-29-1 ED 2.0 - EXPLOSIVE ATMOSPHERES - PART 29-1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR FLAMMABLE GASES |
BS ISO 6145-1 : 2003 | GAS ANALYSIS - PREPARATION OF CALIBRATION GAS MIXTURES USING DYNAMIC VOLUMETRIC METHODS - PART 1: METHODS OF CALIBRATION |
17/30323887 DC : 0 | BS EN 62990-131 - WORKPLACE ATMOSPHERES - PART 1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR TOXIC GASES |
I.S. EN 60079-29-1:2016 | EXPLOSIVE ATMOSPHERES - PART 29-1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR FLAMMABLE GASES |
I.S. EN ISO 6145-1:2008 | GAS ANALYSIS - PREPARATION OF CALIBRATION GAS MIXTURES USING DYNAMIC VOLUMETRIC METHODS - PART 1: METHODS OF CALIBRATION |
ISO 16017-2:2003 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling |
DIN EN 13528-3:2004-04 | Ambient air quality - Diffuse samplers for the determination of concentrations of gases and vapours - Part 3: Guide to selection, use and maintenance |
DIN EN 14042:2003-07 | WORKPLACE ATMOSPHERES - GUIDE FOR THE APPLICATION AND USE OF PROCEDURES FOR THE ASSESSMENT OF EXPOSURE TO CHEMICAL AND BIOLOGICAL AGENTS |
ISO 6143:2001 | Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures |
ISO 6145-1:2003 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.