ISO 7240-15:2014
Current
The latest, up-to-date edition.
Fire detection and alarm systems — Part 15: Point-type fire detectors using smoke and heat sensors
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
23-06-2014
ISO 7240-15:2014 specifies requirements, test methods, and performance criteria for point-type fire detectors using smoke and heat sensors, incorporating in one mechanical enclosure at least one smoke sensor and at least one other sensor which responds to heat, and in which the signal(s) of the smoke sensor(s) is (are) combined with the signal(s) of the heat sensor(s).
The performance of a single sensor within the detector covered by ISO 7240-15:2014 cannot be sufficient for conformity to other parts of ISO 7240 for the single sensor detector.
Certain types of detectors can contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not therefore specified in this standard. However, such detectors are expected to conform to the national requirements and be in line with the recommendations of the Nuclear Energy Agency (NEA) of the Organization for Economic Co-operation and Development (OECD).
For the testing of other types of detectors, or detectors working on different principles, ISO 7240-15:2014 can be used only for guidance. Detectors with special characteristics, developed for specific risks, are not covered in ISO 7240-15:2014.
Committee |
ISO/TC 21/SC 3
|
DevelopmentNote |
Supersedes ISO/DIS 7240-15. (06/2014)
|
DocumentType |
Standard
|
Pages |
64
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
BS ISO 7240-15:2014 | Identical |
NEN ISO 7240-15 : 2014 | Identical |
BS ISO 21927-9:2012 | Smoke and heat control systems Specification for control equipment |
ISO 7240-16:2007 | Fire detection and alarm systems — Part 16: Sound system control and indicating equipment |
12/30249483 DC | BS ISO 7240-14. Fire detection and alarm systems. Part 14. Design, installation, commissioning and service of fire detection and fire alarm systems in and around buildings |
08/30192184 DC : 0 | ISO 15928-4 - HOUSES - DESCRIPTION OF PERFORMANCE - PART 4: FIRE SAFETY |
ISO 21927-9:2012 | Smoke and heat control systems — Part 9: Specification for control equipment |
ISO 15928-4:2017 | Houses — Description of performance — Part 4: Fire safety |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
ISO 7240-5:2012 | Fire detection and alarm systems Part 5: Point-type heat detectors |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
ISO 7240-1:2014 | Fire detection and alarm systems — Part 1: General and definitions |
ISO 7240-7:2011 | Fire detection and alarm systems Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |