Standard tests for measuring reaction-to-fire of products and materials — Their development and application
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
28-02-2014
ISO/TS 3814:2014 describes the relevance of, and how to apply, the fire tests developed by ISO/TC 92/SC 1 so that they can be used effectively to reduce the hazard of fire. Each reaction-to-fire test is related to the different phases of a developing fire in buildings and transport and has to be seen in its relation to the fire scenario and phase of the fire it represents. Some reaction-to-fire tests are proposed to assess the fire hazard in those different phases.
Although ISO/TS 3814:2014 does not address smouldering combustion, this does not mean that smouldering is not important in some fire development situations. However, there are no tests in Subcommittee 1 (SC 1) which currently address this phenomenon.
ISO/TS 3814:2014 is aimed at indicating those ISO tests which produce relevant and useful data for fire safety engineering and those which do not. ISO/TS 3814:2014 is also of use to regulators, people who are performing reaction-to-fire tests including manufacturers and all people who are responsible to create, control, and assess fire safety concepts.
Committee |
ISO/TC 92/SC 1
|
DevelopmentNote |
Supersedes ISO TR 3814. (03/2014)
|
DocumentType |
Technical Specification
|
Pages |
19
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
PD ISO/TS 3814:2014 | Identical |
BS ISO 17554:2014 | Reaction to fire tests. Mass loss measurement |
BS EN ISO 5659-2:2017 | Plastics. Smoke generation Determination of optical density by a single-chamber test |
ISO 17554:2014 | Reaction to fire tests Mass loss measurement |
DIN EN ISO 5659-2:2016-02 (Draft) | PLASTICS - SMOKE GENERATION - PART 2: DETERMINATION OF OPTICAL DENSITY BY A SINGLE-CHAMBER TEST (ISO 5659-2:2017) |
I.S. EN ISO 5659-2:2017 | PLASTICS - SMOKE GENERATION - PART 2: DETERMINATION OF OPTICAL DENSITY BY A SINGLE-CHAMBER TEST (ISO 5659-2:2017) |
UNE-EN ISO 5659-2:2018 | Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test (ISO 5659-2:2017) |
EN ISO 5659-2:2017 | Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test (ISO 5659-2:2017) |
ISO 15928-4:2017 | Houses — Description of performance — Part 4: Fire safety |
ISO 5659-2:2017 | Plastics — Smoke generation — Part 2: Determination of optical density by a single-chamber test |
ISO 5660-1:2015 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) |
ISO 13785-1:2002 | Reaction-to-fire tests for façades — Part 1: Intermediate-scale test |
ISO 5658-2:2006 | Reaction to fire tests Spread of flame Part 2: Lateral spread on building and transport products in vertical configuration |
ISO 13784-2:2002 | Reaction-to-fire tests for sandwich panel building systems Part 2: Test method for large rooms |
ISO 12136:2011 | Reaction to fire tests — Measurement of material properties using a fire propagation apparatus |
ISO/TR 13387-1:1999 | FIRE SAFETY ENGINEERING - PART 1: APPLICATION OF FIRE PERFORMANCE CONCEPTS TO DESIGN OBJECTIVES |
ISO 5657:1997 | Reaction to fire tests Ignitability of building products using a radiant heat source |
ISO/TR 13387-3:1999 | Fire safety engineering Part 3: Assessment and verification of mathematical fire models |
ISO 11925-2:2010 | Reaction to fire tests Ignitability of products subjected to direct impingement of flame Part 2: Single-flame source test |
ISO 13943:2017 | Fire safety — Vocabulary |
ISO 14934-1:2010 | Fire tests Calibration and use of heat flux meters Part 1: General principles |
ISO 5658-4:2001 | Reaction to fire tests — Spread of flame — Part 4: Intermediate-scale test of vertical spread of flame with vertically oriented specimen |
ISO/TR 13387-8:1999 | FIRE SAFETY ENGINEERING - PART 8: LIFE SAFETY - OCCUPANT BEHAVIOUR, LOCATION AND CONDITION |
ISO/TS 16732:2005 | Fire safety engineering Guidance on fire risk assessment |
ISO 24473:2008 | Fire tests — Open calorimetry — Measurement of the rate of production of heat and combustion products for fires of up to 40 MW |
ISO 13785-2:2002 | Reaction-to-fire tests for façades — Part 2: Large-scale test |
ISO/TS 5658-1:2006 | Reaction to fire tests — Spread of flame — Part 1: Guidance on flame spread |
ISO/TR 13387-7:1999 | Fire safety engineering Part 7: Detection, activation and suppression |
ISO/TR 9705-2:2001 | Reaction-to-fire tests Full-scale room tests for surface products Part 2: Technical background and guidance |
ISO/TS 17431:2006 | Fire tests— Reduced-scale model box test |
ISO 11925-3:1997 | Reaction to fire tests — Ignitability of building products subjected to direct impingement of flame — Part 3: Multi-source test |
ISO/TR 11696-1:1999 | Uses of reaction to fire test results Part 1: Application of test results to predict fire performance of internal linings and other building products |
ISO/TR 13387-4:1999 | Fire safety engineering — Part 4: Initiation and development of fire and generation of fire effluents |
ISO 14696:2009 | Reaction-to-fire tests Determination of fire and thermal parameters of materials, products and assemblies using an intermediate-scale calorimeter (ICAL) |
ISO/TR 17252:2008 | Fire tests Applicability of reaction to fire tests to fire modelling and fire safety engineering |
ISO/TR 13387-2:1999 | Fire safety engineering Part 2: Design fire scenarios and design fires |
ISO/TS 14934-4:2007 | Fire tests Calibration of heat flux meters Part 4: Guidance on the use of heat flux meters in fire tests |
ISO/TR 13387-6:1999 | Fire safety engineering Part 6: Structural response and fire spread beyond the enclosure of origin |
ISO 9239-2:2002 | Reaction to fire tests for floorings — Part 2: Determination of flame spread at a heat flux level of 25 kW/m2 |
ISO 14934-2:2013 | Fire tests — Calibration and use of heat flux meters — Part 2: Primary calibration methods |
ISO 20632:2008 | Reaction-to-fire tests — Small room test for pipe insulation products or systems |
ISO 14934-3:2012 | Fire tests — Calibration and use of heat flux meters — Part 3: Secondary calibration method |
ISO 13784-1:2014 | Reaction to fire test for sandwich panel building systems — Part 1: Small room test |
ISO 9239-1:2010 | Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source |
ISO/TR 11696-2:1999 | Uses of reaction to fire test results Part 2: Fire hazard assessment of construction products |
ISO/TR 11925-1:1999 | Reaction to fire tests Ignitability of building products subjected to direct impingement of flame Part 1: Guidance on ignitability |
ISO/TR 13387-5:1999 | Fire safety engineering Part 5: Movement of fire effluents |
ISO/TS 22269:2005 | Reaction to fire tests — Fire growth — Full-scale test for stairs and stair coverings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.