• Shopping Cart
    There are no items in your cart

ISO/TS 5660-3:2012

Current

Current

The latest, up-to-date edition.

Reaction-to-fire tests — Heat release, smoke production and mass loss rate — Part 3: Guidance on measurement

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

06-12-2012

€165.00
Excluding VAT

ISO/TS 5660-3:2012 examines the measurement limitations and applications of the cone calorimeter data as currently used for building products, and recommends ways in which some of these may be overcome for other types of products for other application areas. It compiles information from a large body of experience with regard to the use of the instrument. This information is presented as a set of guidelines, which will help to standardize the use of the cone calorimeter in this wider scope.

Particular guidance is given on aspects of specimen preparation and on the behaviour, such as melting, spalling and intumescing, of specimens exposed to radiant heat. The relevance of specimen thickness and the use of substrate, and methods of fixing to substrate, are also discussed. Advice is given on approaches to testing a variety of "non-standard" products. Recommendations are made on techniques of calibration of the apparatus, selection of appropriate heat flux levels and ignition protocols.

Committee
ISO/TC 92/SC 1
DevelopmentNote
Supersedes ISO TR 5660-3. (12/2012)
DocumentType
Technical Specification
Pages
44
PublisherName
International Organization for Standardization
Status
Current
Supersedes

Standards Relationship
PD ISO/TS 5660-3:2012 Identical

EN 16755:2017 Durability of reaction to fire performance - Classes of fire-retardant treated wood products in interior and exterior end use applications
BS EN ISO 15791-1:2013 Plastics. Development and use of intermediate-scale fire tests for plastics products General guidance
I.S. EN ISO 15791-1:2013 PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE (ISO 15791-1:2014)
UNE-EN 16755:2018 Durability of reaction to fire performance - Classes of fire-retardant treated wood products in interior and exterior end use applications
EN ISO 15791-1:2013 Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014)
UNI EN ISO 15791-1 : 2014 PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE
IEC 60695-1-12:2015 Fire hazard testing - Part 1-12: Guidance for assessing the fire hazard of electrotechnical products - Fire safety engineering
UNE-EN ISO 15791-1:2014 Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014)
ISO 15791-1:2014 Plastics — Development and use of intermediate-scale fire tests for plastics products — Part 1: General guidance
I.S. EN 16755:2017 DURABILITY OF REACTION TO FIRE PERFORMANCE - CLASSES OF FIRE-RETARDANT TREATED WOOD PRODUCTS IN INTERIOR AND EXTERIOR END USE APPLICATIONS
ISO 15928-4:2017 Houses — Description of performance — Part 4: Fire safety
DIN EN ISO 15791-1:2014-05 Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014)

ISO 5660-1:2015 Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)
ISO/TR 9122-1:1989 Toxicity testing of fire effluents Part 1: General
ISO 9705:1993 Fire tests Full-scale room test for surface products
IEC TS 60695-8-3:2008 Fire hazard testing - Part 8-3: Heat release - Heat release of insulating liquids used in electrotechnical products
ISO 5660-2:2002 Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 2: Smoke production rate (dynamic measurement)
NFPA 264A : 1994 STANDARD METHOD OF TEST FOR HEAT RELEASE RATES FOR UPHOLSTERED FURNITURE COMPONENTS OR COMPOSITES AND MATTRESSES USING AN OXYGEN CONSUMPTION CALOMETER
ISO/TS 14934-1:2002 Fire tests Calibration and use of radiometers and heat flux meters Part 1: General principles
ISO 13943:2017 Fire safety — Vocabulary
ISO/TR 3814:1989 Tests for measuring "reaction-to-fire" of building materials — Their development and application
EN 13823:2010+A1:2014 Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item
ISO 17554:2014 Reaction to fire tests Mass loss measurement
ASTM E 1474 : 2014 : REDLINE Standard Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter
ISO/TS 14934-4:2007 Fire tests Calibration of heat flux meters Part 4: Guidance on the use of heat flux meters in fire tests
ISO 554:1976 Standard atmospheres for conditioning and/or testing — Specifications
ISO/TR 14697:1997 Fire tests — Guidance on the choice of substrates for building products
ISO 13927:2015 Plastics — Simple heat release test using a conical radiant heater and a thermopile detector
ISO 14697:2007 Reaction-to-fire tests — Guidance on the choice of substrates for building and transport products
IEC 60332-3-10:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
ISO 11907-4:1998 Plastics — Smoke generation — Determination of the corrosivity of fire effluents — Part 4: Dynamic decomposition method using a conical radiant heater
ASTM E 1354 : 2017 : REDLINE Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.