MIL-PRF-39016 Revision H:2017
Current
The latest, up-to-date edition.
Relays, Electromagnetic, Established Reliability, General Specification for
13-09-2017
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
Specifies the general requirements for electromagnetic, hermetically sealed relays for use in electronic and communication-type equipment.
| DocumentType |
Standard
|
| Pages |
52
|
| PublisherName |
US Military Specs/Standards/Handbooks
|
| Status |
Current
|
| Supersedes |
This specification covers the general requirements for electromagnetic, hermetically sealed relays for use in electronic and communication-type equipment (see 6.1). These relays are designed to operate over the full range from low level to power switching with contact ratings up to 5 amperes alternating current (ac) or direct current (dc). The failure rate level is established at a confidence level of 90 percent for qualification and 60 percent for maintenance of qualification based on 100,000 cycles at +125°C under the rated load conditions specified herein. CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. CAUTION: Pick-up, hold, and dropout voltages are for test purposes only and are not to be used as design criteria. For additional application and caution information, see 6.1.
| MIL-R-39016-39 Revision G:2014 | RELAYS, ELECTROMAGNETIC, HERMETICALLY SEALED, 4PDT, LOW-LEVEL TO 3 AMPERES (400 MILLIWATTS) |
| MIL-STD-1580 Revision B:2003 | Destructive Physical Analysis for Electronic, Electromagnetic, and Electromechanical Parts |
| MIL-PRF-39016-14 Revision F:2016 | Relays, Electromagnetic, Established Reliability, 4PDT, Low Level To 2 Amperes (0.150-Inch Terminal Spacing) |
| MIL-PRF-39016-20 Revision J:2004 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection |
| MIL STD 11991 : A | GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES |
| DSCC 85138 : D | RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE, WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND REVERSE POLARITY PROTECTION |
| MIL-PRF-39016-18 Revision H:2005 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1 Ampere with Internal Diode for Coil Transient Suppression, Terminals 0.100-Inch Grid Pattern |
| MIL-DTL-15103 Revision G:2015 | Salinity Indicating Equipment |
| MIL-PRF-39016-44 Revision E:2006 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes, Terminals 0.200-Inch Grid Pattern (Sensitive, 100/125 Milliwatts, Coil Operate Power at 25 Degrees C) |
| MIL-PRF-39016-7 Revision G:2004 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1 Ampere |
| MIL-HDBK-1760 Revision A:2004 | Aircraft/Store Electrical Interconnection System |
| MIL-PRF-39016-27 Revision F:2005 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 0.5 Ampere (Latching) with Internal Diodes for Coil Transient Suppression |
| MIL-PRF-39016-28 Revision F:2005 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 0.5 Ampere (Latching) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection |
| MIL-PRF-39016-45 Revision F:2018 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (Latching) |
| MIL-PRF-39016-30 Revision F:2005 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Latching) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection |
| MIL-PRF-39016-37 Revision D:2014 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.150-Inch Terminal Spacing), with Internal Diode for Coil Transient Suppression |
| MIL-PRF-39016-47 Revision C:2006 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 0.5 Ampere (.100 D.I.P. Terminal Spacing) One-Tenth Size, Sensitive, Bi-Stable, (Latching) |
| DSCC 84173 : F | RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
| NASA MSFC STD 3012 : 2012 | ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE |
| MIL-PRF-39016-53 Revision C:2006 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing) with Internal Diode for Coil Transient Suppression |
| MIL-PRF-39016-25 Revision F:2005 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1.0 Ampere (Sensitive, 40 Milliwatts) with Internal Diode for Coil Transient Suppression |
| MIL-PRF-39016-24 Revision F:2005 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1.0 Ampere with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection |
| MIL-PRF-39016-8 Revision J:2016 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 0.5 Ampere (Latching) |
| MIL-PRF-39016-22 Revision F:2016 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.200-Inch Terminal Spacing) Coil Transient Suppressed |
| MIL-PRF-39016-11 Revision G:2004 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive, 60 Milliwatts, Coil Operate Power at 25 Degrees C) |
| MIL-PRF-39016-26 Revision F:2005 | Relays, Electromagnetic, Established Reliability SPDT, Low Level to 1.0 Ampere (Sensitive, 40 Milliwatts) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection |
| MIL-PRF-39016-54 Revision D:2006 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing) with Internal Diode for Coil Transient Suppression and Reverse Polarity Protection |
| MIL-PRF-39016-41 Revision E:2005 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1 Ampere, Terminals 0.100-Inch Grid Pattern Sensitive, 60 Milliwatts, Coil Operate Power at 25 Degrees Celsius |
| MIL R 39016/40 : G | RELAYS, ELECTROMAGNETIC, 4PDT, LOW LEVEL TO 2.0 AMPERES (0.100-INCH TERMINAL SPACING) |
| MIL-PRF-39016-21 Revision H:2013 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive, 60 Milliwatts) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection |
| MIL-PRF-39016-6 Revision L:2004 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.200-Inch Terminal Spacing) |
| MIL-PRF-39016-15 Revision M:2014 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere with Internal Diode for Coil Transient Suppression |
| MIL-PRF-39016-13 Revision K:2013 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.150-Inch Terminal Spacing) |
| MIL-PRF-39016-48 Revision D:2013 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 0.5 Ampere (.100 D.I.P. Terminal Spacing) One-Tenth Size, Sensitive, Monostable |
| MIL-PRF-39016-36 Revision C:2006 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing), Latching, with Internal Diodes for Coil Transient Suppression and Reverse Polarity Protection |
| MIL R 5757/7 : G | RELAYS, ELECTROMAGNETIC, HERMETICALLY SEALED, 4PDT, LOW LEVEL TO 2 AMPERES |
| MIL-PRF-39016-23 Revision F:2005 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1.0 Ampere with Internal Diode for Coil Transient Suppression |
| MIL-PRF-39016-19 Revision H:2005 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1 Ampere with Internal Diode for Coil Transient Suppression and Polarity Reversal Protection, Terminals 0.100-Inch Grid Pattern |
| DSCC 84172 : F | RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE |
| MIL-PRF-39016-29 Revision H:2017 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Latching) with Internal Diodes for Coil Transient Suppression |
| MIL-PRF-83726 Revision H:2017 | Relays, Hybrid and Solid State, Time Delay, General Specification for |
| MIL-PRF-39016-12 Revision H:2016 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Latching) |
| MIL-PRF-39016-35 Revision E:2017 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4 PDT Low Level to 2 Amperes (0.150-Inch Terminal Spacing), Latching, with Internal Diodes for Coil Transient Suppression |
| MIL-PRF-39016-42 Revision E:2006 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere with Internal Diode for Coil Transient Suppression, Terminals .100-Inch Grid Pattern (Sensitive 60 Milliwatts, Coil Operate Power at 25 Degree C) |
| MIL-R-39016-34 Revision F:2006 | Relays, Electromagnetic, DPDT, Low Level to 1.0 Ampere, (0.100-Inch Terminal Spacing) (No S/S Document) |
| MIL-PRF-39016-16 Revision G:2004 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive, 60 Milliwatts) with Internal Diode for Coil Transient Suppression |
| MIL R 39016/32 : F | RELAYS, ELECTROMAGNETIC, DPDT, LOW LEVEL TO 2 AMPERES (LATCHING) |
| MIL-PRF-39016-9 Revision K:2016 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere |
| MIL-PRF-39016-17 Revision J:2017 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level TO 1 Ampere Terminals 0.100-Inch Grid Pattern |
| MIL-PRF-39016-43 Revision E:2005 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere, with Internal Diodes for Coil Transient Suppression, and Polarity Reversal Protection Terminals 0.100-Inch Grid Pattern (Sensitive, 60 Milliwatts, Coil Operate Power at 25 Degrees C) |
| MIL R 5757/1 : K | RELAYS, ELECTRICAL, HERMETICALLY SEALED, 6PDT, LOW LEVEL TO 2 AMPERES |
| MIL-PRF-39016-10 Revision G:2004 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1.0 Ampere (Sensitive, 40 Milliwatts, Coil Operate Power at 25 Degrees C) |
| MIL-STD-202-212 Base Document:2015 | Method 212, Acceleration |
| MIL-STD-202-211 Base Document:2015 | Method 211, Terminal Strength |
| MIL-STD-202-302 Base Document:2015 | Method 302, Insulation Resistance |
| MIL-STD-883 Revision K:2016 | Microcircuits |
| MIL-STD-202-210 Base Document:2015 | Method 210, Resistance to Soldering Heat |
| MIL-STD-1276 Revision H:2013 | Leads for Electronic Component Parts |
| MIL-STD-1686 Revision C:1995 | Electrostatic Discharge Control Program for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices) (S/S by ANSI/ESD S20.20) |
| MIL-STD-202-101 Base Document:2015 | Method 101, Salt Atmosphere (Corrosion) |
| MIL-STD-750 Revision F:2011 | Test Methods for Semiconductor Devices |
| MIL-STD-202-107 Base Document : 2015 | Method 107, Thermal Shock |
| MIL-STD-202-301 Base Document:2015 | Method 301, Dielectric Withstanding Voltage |
| MIL-HDBK-338 Revision B:1998 | Electronic Reliability Design Handbook |
| IEEE 315 : 1975 | GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS) |
| MIL-STD-202-215 Base Document:2015 | Method 215, Resistance to Solvents |
| MIL-STD-790 Revision G:2011 | Established Reliability and High Reliability Qualified Products List (QPL) Systems for Electrical, Electronic, and Fiber Optic Parts Specifications |
| MIL-HDBK-263 Revision B:1994 | Electrostatic Discharge Control Handbook for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices) (Metric) (S/S by ESD TR20.20) |
| MIL-STD-202-105 Base Document:2015 | Method 105, Barometric Pressure (Reduced) |
| MIL-STD-202-208 Base Document:2015 | Method 208, Solderability |
| MIL-STD-202 Revision H:2015 | Electronic and Electrical Component Parts |
| MIL-STD-1285 Revision D:2004 | Marking of Electrical and Electronic Parts |
| EIA 557 : 2006 | STATISTICAL PROCESS CONTROL SYSTEMS |
| MIL-STD-202-214 Base Document:2015 | Method 214, Random Vibration |
| MIL-STD-690 Revision D:2005 | Failure Rate (FR) Sampling Plans and Procedures |
| MIL-STD-202-312 Base Document:2015 | Method 312, Life, Intermediate Current Switching |
| MIL-STD-202-204 Base Document:2015 | Method 204, Vibration, High Frequency |
| MIL-STD-202-112 Base Document:2015 | Test Method Standard Method 112, Seal |
| MIL-STD-202-213 Base Document:2015 | Method 213, Shock (Specified Pulse) |
| MIL-STD-202-307 Base Document:2015 | Method 307, Contact Resistance |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.