MIL-PRF-8805 Revision G:2016
Current
The latest, up-to-date edition.
SWITCHES AND SWITCH ASSEMBLIES, SENSITIVE, SNAP ACTION (BASIC, LIMIT, PUSH BUTTON AND TOGGLE SWITCHES), GENERAL SPECIFICATION FOR
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - APPLICATION INFORMATION
APPENDIX B - DC INDUCTOR CALIBRATION PROCESS
Describes the general requirements for snap action sensitive switches and switch assemblies. The sensitive switch assemblies include limit, push-button, and toggle operated types.
Committee |
FSC 5930
|
DevelopmentNote |
Supersedes MIL S 8805 (D). (05/2001)
|
DocumentType |
Standard
|
Pages |
108
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
MIL-PRF-8805-55 Revision J:2010 | SWITCH, PUSH, MICROPHONE, DPST, NORMALLY OPEN, FOOT OPERATED, MOMENTARY, UNSEALED AND WATERTIGHT |
MIL-PRF-8805-48 Revision H:2004 | SWITCHES, SENSITIVE, LIMIT, ROLLER LEVER, SELF-RETURN, RESILIANT SEAL, FLUID RESISTANT |
MIL-PRF-8805-19 Revision F:2004 | SWITCHES, SENSITIVE-MOMENTARY, 2 CIRCUIT, 40 AMPERES, UNSEALED |
MIL-PRF-8805-27 Revision E:2006 | SWITCHES, SENSITIVE, 10 AMPERES AND LOW LEVEL, UNSEALED |
MIL-PRF-8805-17 Revision G:2004 | SWITCHES, SENSITIVE-MAINTAINED, 6 CIRCUIT, 15 AMPERES, UNSEALED |
MS24456 Revision E:2005 | Switch, Sensitive, Sealed, SPDT, Class A5 or B8 |
MIL-PRF-8805-72 Revision L:2008 | SWITCHES, SENSITIVE, SPDT, PLUNGER, 4 AMPERES, HERMETICALLY SEALED CONTACTS, UNSEALED PLUNGER |
MIL-PRF-8805-116 Base Document:2007 | SWITCHES, SENSITIVE, 4PDT PLUNGER, 4 AMPERES, HERMETICALLY SEALED CONTACTS, RESILIENT SEALED PLUNGER |
MIL-PRF-8805-100 Revision G:2012 | Switches, Sensitive, Plunger, 10 Amperes 2PDT and 7 Amperes 4PDT, Resilient Seal |
MIL-PRF-8805-96 Revision E:2004 | SWITCHES, PUSH, MOMENTARY, SPST, 5 AMPERES |
MIL-PRF-8805-14 Revision F:2004 | SWITCHES, SENSITIVE-MAINTAINED, 2 CIRCUIT, 10 AMPERES, UNSEALED |
MIL-PRF-8805-84 Revision F:2012 | Switches, Sensitive, Watertight, 10 Amperes, Double Break |
MIL S 8805/59 : D | SWITCH, ACTUATOR, ROLLER LEAF |
MIL S 8805/58 : E | SWITCH, ACTUATOR, EXTENDED PLUNGER TYPE |
MIL-PRF-8805-38 Revision H:2012 | Switches, Push, Momentary, 4 Circuit, 4 Amperes or Low Level, Dusttight |
MIL-DTL-917 Revision F:2014 | ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR |
MIL-PRF-8805-11 Revision J:2004 | SWITCHES, SENSITIVE-MOMENTARY, 2 CIRCUIT, 10 AMPERES, UNSEALED |
MIL-PRF-8805-114 Revision D:2012 | Switch Assembly, Sensitive, Roller Plunger, SPDT, 7 Amperes, Watertight Seal (No S/S Document) |
MIL-PRF-8805-26 Revision J:2012 | Switches, Assemblies, Sensitive, Toggle Lever (with Integral Leaf), 5 Amperes, Unsealed |
MIL-PRF-8805-110 Revision E:2012 | SWITCHES, PUSHBUTTON, MOMENTARY, 5 AMPERES AND LOW LEVEL, MINIATURE, DUSTTIGHT OR WATERTIGHT |
MIL STD 11991 : A | GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES |
MIL-PRF-8805-49 Revision J:2012 | Switches, Sensitive, Limit, Rotary Linkage Lever (Nonself-Return), Resilient Seal, Fluid Resistant |
MIL-DTL-16556 Revision F:2017 | Valve, Solenoid, Three-Way Bypass ( Naval Shipboard Use ) |
MIL-PRF-8805-8 Revision H:2012 | Switches, Sensitive, SPDT, Leaf Actuator, Low Level to 4 Amperes, Hermetic Seal |
MIL S 8805/53 : E | SWITCHES, SENSITIVE, 4 CIRCUIT, ROLLER-LEVER, WATERTIGHT |
MIL-S-8805-51 Revision D:2006 | SWITCHES, SENSITIVE, ROLLER-LEVER, WATERTIGHT |
MIL-PRF-22885-114 Base Document:2009 | SWITCHES, PUSHBUTTON, WHITE LIGHT EMITTING DIODE (LED) OR 4 LAMP REPLACEABLE INCANDESCENT ILLUMINATED, STANDARD, NIGHT VISION IMAGING SYSTEM (NVIS) AND SUNLIGHT READABLE DISPLAYS, DIMMABLE, SPDT, DPDT AND 4PDT, LOW LEVEL TO 7 AMPERES, SEALED AND UNSEALED, SOLDER AND COMMON TERMINATION SYSTEM (CTS) TERMINATIONS |
MIL-PRF-8805-39 Revision J:2014 | SWITCHES, SENSITIVE, LIMIT, PLUNGER, 7 AMPERES, RESILIENT SEAL, FLUID RESISTANT |
MIL-PRF-8805-25 Revision F:2004 | SWITCHES, PUSH, MOMENTARY, 2 CIRCUIT, UNSEALED AND SEALED |
MIL-PRF-8805-43 Revision K:2014 | SWITCHES, SENSITIVE, PLUNGER, RESILIENT SEAL, FLUID RESISTANT |
MIL-PRF-8805-18 Revision G:2004 | SWITCHES, SENSITIVE, MOMENTARY, 6 CIRCUIT, 15 AMPERES, UNSEALED |
MIL-PRF-8805-20 Revision N:2008 | SWITCHES, PUSH, MOMENTARY, 2 CIRCUIT, UNSEALED AND SEALED |
MIL-DTL-2212 Revision K:2014 | CONTACTORS AND CONTROLLERS, ELECTRIC MOTOR AC OR DC, AND ASSOCIATED SWITCHING DEVICES |
MIL HDBK 1132 : 0 | SWITCHES, SELECTION AND USE OF |
MIL-PRF-8805-92 Revision D:2006 | SWITCH ASSEMBLIES, SENSITIVE, LEVER LOCK, 5 AMPERES, UNSEALED |
MIL-PRF-8805-22 Revision E:2017 | SWITCHES, SENSITIVE, SPDT, 5 AMPERES, UNSEALED |
MIL-PRF-8805-68 Revision L:2008 | SWITCHES, SENSITIVE, SPDT, 4 AMPERES, HERMETIC SEAL |
MIL-PRF-22885-115 Base Document:2012 | SWITCHES, PUSHBUTTON, ULTRA-COMPACT, LED ILLUMINATION, NVIS, SEALED |
MIL-S-8805-85 Revision E:2005 | SWITCH, SENSITIVE, ROTARY (NON-SELF RETURN), 4 AMPERES, RESILIENT SEAL |
MIL-PRF-8805-109 Revision C:2006 | SWITCH, SENSITIVE, SPDT, UNSEALED, 7 AMPERES, 0.156 WIDTH BASE |
MIL-PRF-8805-32 Revision J:2010 | SWITCHES, SENSITIVE, SPDT, 7 AMPERES, WATERTIGHT |
MIL-PRF-8805-7 Revision H:2006 | SWITCHES, PUSH, MOMENTARY, 2 CIRCUIT OR SPST (10 AMPERES), UNSEALED |
MIL-PRF-8805-95 Revision J:2006 | SWITCHES, PUSH, 2PDT, MOMENTARY, 1 AMPERE, UNSEALED |
MIL S 8805/50 : D | SWITCHES, SENSITIVE, ROLLER-LEVER, WATERTIGHT |
MIL-PRF-8805-98 Revision E:2010 | SWITCHES, SENSITIVE, SWITCH ASSEMBLY, TOGGLE, 7 AMPERES, PANEL SEAL, TOGGLE SEAL |
NASA KSC STD E 0001 : 2008 | DESIGN OF ELECTRICAL CONTROL AND MONITORING SYSTEMS, EQUIPMENT (GSE), AND PANELS, STANDARD FOR |
NASA MSFC STD 3012 : 2012 | ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE |
MIL-PRF-8805-99 Revision H:2001 | SWITCHES, PUSH, 2 CIRCUIT AND DPDT, ALTERNATE AND MOMENTARY ACTION, 2 AMPERES, SPLASHPROOF |
MIL-PRF-8805-40 Revision K:2014 | SWITCHES, SENSITIVE, PLUNGER, RESILIENT SEAL, FLUID RESISTANT |
MIL-PRF-8805-104 Revision D:2012 | SWITCHES, SENSITIVE, PLUNGER, 7 AMPERES, 4PDT, RESILIENT SEAL, GROUNDED PLUNGER |
MIL-PRF-8805-44 Revision F:2006 | SWITCHES, SENSITIVE, SPST, 5 AMPERES, RESILIENT SEAL |
SAE ARP 1281 : 2002 | ACTUATORS: AIRCRAFT FLIGHT CONTROLS, POWER OPERATED, HYDRAULIC, GENERAL SPECIFICATION FOR |
MIL-PRF-22885-79 Revision E:2006 | SWITCHES, PUSH BUTTON, ILLUMINATED, MOMENTARY, SPDT AND DPDT, ONE LAMP, 7 AMPERE SILVER CONTACTS, 1 AMPERE GOLD CONTACT |
MIL-PRF-8805-106 Revision B:2006 | SWITCHES, SENSITIVE, SPDT, LOW LEVEL TO 2 AMPERES, 400 DEGREE F, UNSEALED |
MIL-PRF-8805-34 Revision E:2004 | SWITCHES, SENSITIVE-MAINTAINED, 2 CIRCUIT, 40 AMPERES, UNSEALED |
MIL-PRF-8805-47 Revision G:2004 | SWITCHES, SENSITIVE, SPDT, LEVER, 25 AMPERES, HERMETIC |
MIL-PRF-8805-115 Base Document:2006 | SWITCHES, PUSHBUTTON, MOMENTARY, DOUBLE POLE, 4 AMPERES, LOW LEVEL, SEALED |
MIL-PRF-22885-113 Revision A:2010 | SWITCHES, PUSHBUTTON, ILLUMINATED, 1.17 BY .96, LIGHT EMITTING DIODE (LED), SUNLIGHT READABLE, VOLTAGE DIMMABLE, NIGHT VISION GOGGLE COMPATIBLE, EMC COMPLIANT, COMMON TERMINATION SYSTEM (CTS), SPDT, DPDT, 4PDT, LOGIC LEVEL TO 7.5 AMPERES, DRIPPROOF, WATERTIGHT, SPLASHPROOF, HIGH IMPACT SHOCK RESISTANT |
MIL-PRF-8805-65 Revision F:2017 | Switches, Sensitive, DPDT, Plunger, 5 Amperes, Resilient Seal |
MIL-PRF-22885-96 Revision D:2010 | SWITCHES, PUSHBUTTON, ILLUMINATED, 4-LAMP, RFI SHIELDED |
MIL-PRF-22885-83 Revision E:2001 | SWITCH, PUSH BUTTON, ILLUMINATED, (2.330 LONG X .750 SQUARE) |
MIL-PRF-22885-111 Revision B:2010 | SWITCHES, PUSHBUTTON, LIGHT EMITTING DIODE (LED) ILLUMINATED, STANDARD, NIGHT VISION IMAGING SYSTEM (NVIS) AND SUNLIGHT READABLE DISPLAYS, SPDT AND DPDT, LOW LEVEL TO 7 AMPERES, SEALED AND UNSEALED, SOLDER AND COMMON TERMINATION SYSTEM (CTS) TERMINATIONS |
MIL-PRF-22885-108 Revision H:2017 | SWITCHES, PUSHBUTTON, ILLUMINATED, 4-LAMP REPLACEABLE INCANDESCENT OR NON-REPLACEABLE LIGHT EMITTING DIODE (LED), 0.750 SQUARE, SPDT, DPDT, 4PDT SILVER CONTACTS - 2 CIRCUIT (5 AMPERES) OR SPDT (7.5 AMPERES); GOLD CONTACTS - LOW LEVEL TO 1 AMPERE, OPTIONAL ELECTRONIC COMPONENTS, SUNLIGHT READABLE DISPLAY (DRIPPROOF, WATERTIGHT, SPLASHPROOF, EMI/RFI SHIELDING, HIGH IMPACT SHOCK |
MIL-PRF-8805-80 Revision G:2009 | SWITCH, SENSITIVE, LIMIT, HERMETIC SEAL |
MIL-PRF-8805-41 Revision C:2006 | SWITCHES, SENSITIVE, DPDT, PLUNGER, 5 AMPERE, HERMETIC |
MIL-PRF-22885-112 Revision A:2013 | Switches, Pushbutton, White Light Emitting Diode (LED) Illuminated, Standard, Night Vision Imaging System (NVIS) and Sunlight Readable Displays, Dimmable, SPDT and DPDT, Low Level to 7 Amperes, Sealed and Unsealed, Solder and Common Termination System (CTS) Terminations |
MIL-PRF-8805-15 Revision G:2004 | SWITCHES, SENSITIVE-MOMENTARY, 4 CIRCUIT, 15 AMPERES, UNSEALED |
MIL-PRF-8805-56 Revision G:2006 | SWITCH, ASSEMBLIES, SENSITIVE, INTERLOCK, UNSEALED |
MIL-PRF-8805-3 Revision L:2009 | Switches, Push, 10 Amperes or Low Level, Dusttight |
MIL-PRF-8805-76 Revision H:2004 | SWITCHES, SENSITIVE, 2 CIRCUIT (5 AMPERES) OR SPST (8 AMPERES), UNSEALED |
MIL-PRF-8805-107 Revision C:2004 | SWITCHES, PUSH, MOMENTARY AND PUSH-PULL, 10 AMPERES, DUSTTIGHT |
MIL-PRF-8805-4 Revision P:2006 | SWITCHES, SENSITIVE, SPDT, UNSEALED |
MIL-PRF-8805-23 Revision J:2014 | SWITCH ASSEMBLIES, SENSITIVE, PUSH, MOMENTARY, 5 AMPERES, UNSEALED |
MIL-PRF-8805-73 Revision K:2006 | SWITCHES, SENSITIVE, SPDT, PLUNGER, 4 AMPERES, HERMETICALLY SEALED CONTACTS, RESILIENT SEALED PLUNGER |
MIL-PRF-8805-93 Revision E:2010 | SWITCHES, TOGGLE, UNSEALED, 7.0 AMPERES |
MIL-PRF-8805-74 Revision L:2006 | SWITCHES, SENSITIVE, SPDT, 4 AMPERES, HERMETIC SEAL |
MIL-PRF-8805-70 Revision L:2012 | SWITCHES, SENSITIVE, DPDT AND 4PDT, PLUNGER OR ROLLER, 4 AMPERES, HERMETICALLY SEALED CONTACTS, RESILIENT SEALED PLUNGER |
MIL-PRF-8805-90 Revision G:2007 | SWITCH, SENSITIVE, LOW FORCE, SPDT, 10 AMPERES, UNSEALED |
MIL-PRF-8805-45 Revision G:2006 | SWITCHES, SENSITIVE, SPST, 5 AMPERES, RESILIENT SEAL |
MIL-PRF-8805-82 Revision E:2006 | SWITCHES, SENSITIVE, LEAF, SPDT, 4 AMPERES, HERMETIC |
MIL-PRF-8805-101 Revision K:2004 | SWITCHES, SENSITIVE, 2 CIRCUIT (5 AMPERES) OR SPST (8 AMPERES), UNSEALED, LOW LEVEL SWITCHING, FORM C OR FORM Z |
MIL-STD-202-207 Base Document:2015 | METHOD 207, HIGH IMPACT SHOCK |
MIL-STD-202-211 Base Document:2015 | METHOD 211, TERMINAL STRENGTH |
MIL-STD-202-302 Base Document:2015 | Method 302, Insulation Resistance |
MIL R 5757/10 : L | RELAYS, ELECTROMAGNETIC, HERMETICALLY SEALED, DPDT, LOW LEVEL TO 2 AMPERES |
MIL-STD-202-109 Base Document:2015 | Method 109, Explosion |
ANSI/NCSL Z540 3 : 2006(R2013) | REQUIREMENTS FOR THE CALIBRATION OF MEASURING AND TEST EQUIPMENT |
MIL-STD-202-210 Base Document:2015 | Method 210, Resistance to Soldering Heat |
MIL-STD-202-101 Base Document:2015 | Method 101, Salt Atmosphere (Corrosion) |
MIL-PRF-15160-2 Revision J:2014 | Fuses, Instrument, Power, and Telephone (Nonindicating), Style F02 |
MIL-STD-202-107 Base Document:2015 | Method 107, Thermal Shock |
MIL-STD-202-106 Base Document:2015 | Method 106, Moisture Resistance |
MIL-STD-202-301 Base Document:2015 | Method 301, Dielectric Withstanding Voltage |
IPC J STD 002 : D | SOLDERABILITY TESTS FOR COMPONENT LEADS, TERMINATIONS, LUGS, TERMINALS AND WIRES |
MIL-STD-202-215 Base Document:2015 | METHOD 215, RESISTANCE TO SOLVENTS |
SAE AS7928B | Terminals, Lug: Splices, Conductor: Crimp Style, Copper, General Specification For |
MIL-STD-108 Revision E:1966 | DEFINITION OF AND BASIC REQUIREMENT FOR ENCLOSURE FOR ELECTRIC AND ELECTRONIC EQUIPMENT |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
MIL-STD-202-310 Base Document:2015 | Method 310, Contact-Chatter Monitoring |
SAE AS25244B | CIRCUIT BREAKER, TRIP-FREE, PUSH-PULL, 5 THRU 50 AMP, TYPE I |
MIL-STD-202-110 Base Document:2015 | Method 110, Sand and Dust |
MIL-STD-202-105 Base Document:2015 | Method 105, Barometric Pressure (Reduced) |
MIL-STD-202-208 Base Document:2015 | Method 208, Solderability |
MIL-STD-202 Revision H:2015 | ELECTRONIC AND ELECTRICAL COMPONENT PARTS |
MIL-STD-1285 Revision D:2004 | MARKING OF ELECTRICAL AND ELECTRONIC PARTS |
FED-STD-H28 Revision A:1994 | Screw-Thread Standards for Federal Services |
MIL-STD-202-214 Base Document:2015 | Method 214, Random Vibration |
SAE AS58091A | Circuit Breakers, Trip-Free, Aircraft General Specification For |
MIL-STD-202-204 Base Document:2015 | Method 204, Vibration, High Frequency |
MIL-STD-202-112 Base Document:2015 | METHOD 112, SEAL |
MIL-STD-202-213 Base Document:2015 | Method 213, Shock (Specified Pulse) |
MIL-STD-202-307 Base Document:2015 | Method 307, Contact Resistance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.