• Shopping Cart
    There are no items in your cart

NBN EN 50381 : 2005

Current

Current

The latest, up-to-date edition.

TRANSPORTABLE VENTILATED ROOMS WITH OR WITHOUT AN INTERNAL SOURCE OF RELEASE

Published date

12-01-2013

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Definitions
4 Construction requirements for TVR's and ducting
   4.1 General
   4.2 Degree of ingress protection
   4.3 Design and construction
   4.4 Mechanical strength
   4.5 Penetrations
   4.6 Floor drains
   4.7 Floors
   4.8 Doors
   4.9 Inspection window(s)
   4.10 Apertures
   4.11 Enclosures
5 Requirements for TVR's, equipment group I, type of
   protection vM2
6 Ventilation requirements for TVR's, equipment group II
7 Additional ventilation requirements for TVR's with an
   internal source of release
8 Temperature limits
9 Minimum safety provisions and devices
10 Additional safety provisions and devices for TVR's
   meeting the requirements of type of protection v2 and vM2
11 Additional requirements for TVR's with an internal source
   of release
   11.1 Assessment of containment systems
   11.2 Release conditions
        11.2.1 No release
        11.2.2 Release of a flammable liquid
   11.3 Design requirements for the containment system
        11.3.1 Infallible parts of the containment system
        11.3.2 Containment system with limited release
   11.4 Ignition capable apparatus in the case of type of
        protection v2
   11.5 Location of apparatus in the case of type of
        protection v3
   11.6 Internal hot surfaces
        11.6.1 Loss of minimum pressure differential, type
               of protection v2
        11.6.2 Loss of ventilation flow, type of protection v2
        11.6.3 Loss of ventilation flow, type of protection v3
   11.7 Potential source of internal release
12 Requirements for gas detectors
13 Supply of protective gas
   13.1 Ventilation
   13.2 Leakage Compensation of a Breathable Atmosphere (LCBA)
   13.3 Density limits
14 Type verification and tests
   14.1 Sequence of tests
   14.2 Thermal tests
   14.3 Overpressure test
   14.4 Purging test
   14.5 Verification of minimum pressure differential
   14.6 Ventilation flow rate tests for TVR's with an internal
        source of release
   14.7 Overpressure test for containment systems with limited
        release
   14.8 Verification of sequence of operation of the safety
        devices
   14.9 Additional tests
15 Routine tests
   15.1 Test conditions
   15.2 Verification of minimum pressure differential
   15.3 Ventilation flow rate tests for TVR's with an internal
        source of release
   15.4 Overpressure test for containment systems with limited
        release
   15.5 Verification of sequence of operation of the safety
        devices
   15.6 Additional tests
16 Marking
   16.1 TVR's all cases
   16.2 TVR's with a containment system
   16.3 Safety related control systems
   16.4 Additional marking
17 Instructions
Annex A (normative) Method of protection of electrical
        apparatus containing a potential release of a
        flammable gas or vapour
      A.1 Introduction
      A.2 Definitions
      A.3 Requirements
Annex B (normative) Method of protection of electrical
        apparatus containing a potential release of a
        flammable liquid
      B.1 Introduction
      B.2 Definitions
      B.3 Requirements
      B.4 Flammable non-flashing liquids
      B.5 Spark and particle barriers
      B.6 Flashing liquids
Annex C (informative) Determination of peak rise in enclosure
        pressure, resulting from an internal release of a
        flashing liquid
      C.1 Introduction
      C.2 Definitions
Annex D (informative) Method of protection of electrical
        apparatus containing a potential release of a
        flammable gas or vapour
Annex E (informative) Mathematical model of dilution of a
        source of release
Bibliography

Presents the specific requirements for the construction and testing of transportable ventilated rooms (TVR's), such as skid mounted analyser houses with type of protection 'v' intended for use in potentially explosive atmospheres.

DocumentType
Standard
PublisherName
Belgian Standards
Status
Current

Standards Relationship
DIN EN 50381 : 2005 COR 1 2006 Identical
NEN EN 50381 : 2004 C1 2006 Identical
SN EN 50381 : 2004 Identical
BS EN 50381:2004 Identical
EN 50381 : 2004 COR 2005 Identical
I.S. EN 50381:2004 Identical
UNE-EN 50381:2005 Identical
NF EN 50381 : 2004 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.