• NBN EN 60079-15 : 2010

    Current The latest, up-to-date edition.

    EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N"

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Belgian Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General
       4.1 Apparatus grouping and temperature
             classification
       4.2 Potential ignition sources
    5 Temperatures
       5.1 Environmental influences
       5.2 Service temperature
       5.3 Maximum surface temperature
       5.4 Surface temperature and ignition temperature
       5.5 Small components
    6 Requirements for electrical apparatus
       6.1 General
       6.2 Mechanical strength of apparatus
       6.3 Opening times
       6.4 Circulating currents
       6.5 Gasket retention
       6.6 Degree of protection of enclosure (IP)
       6.7 Clearances, creepage distances and separations
       6.8 Electric strength
    7 Non-metallic enclosures and non-metallic parts
       of enclosures
       7.1 General
       7.2 Thermal endurance
       7.3 Electrostatic charges on external non-metallic
             materials of enclosures
       7.4 Threaded holes
       7.5 Thermal shock
       7.6 Resistance to light
    8 Enclosures containing light metals
       8.1 Material composition
       8.2 Threaded holes
    9 Fasteners
       9.1 General
       9.2 Special fasteners
    10 Interlocking devices
    11 Bushings
    12 Materials used for cementing
    13 Ex components
       13.1 Type of protection "n"
       13.2 Mounting
       13.3 Internal mounting
       13.4 External mounting
    14 Connection facilities and terminal compartments
       14.1 General
       14.2 Connection for external conductors
       14.3 Internal connection facilities
    15 Connection facilities for earthing or bonding
       conductors
    16 Entries into enclosures
    17 Supplementary requirements for non-sparking electrical
       machines
       17.1 General
       17.2 Connection facilities for external conductors
       17.3 Neutral point connections
       17.4 Radial air gap
       17.5 Ventilation systems
       17.6 Bearing seals and shaft seals
       17.7 Rotor cages
       17.8 Surface temperature limitation
       17.9 Additional requirements for machines with rated
             voltage greater than 1kV
    18 Supplementary requirements for switchgear
    19 Supplementary requirements for non-sparking fuses and
       fuse assemblies
       19.1 Fuses
       19.2 Temperature class of an apparatus
       19.3 Fuse mounting
       19.4 Fuse enclosures
       19.5 Replacement fuse identification
    20 Supplementary requirements for non-sparking plugs and
       sockets
       20.1 Plugs and sockets for external connections
       20.2 Maintaining degree of protection
       20.3 Plugs and sockets for internal connections
       20.4 Sockets that do not have plugs inserted in normal
             operation
    21 Supplementary requirements for non-sparking luminaires
       21.1 General
       21.2 Construction
       21.3 Other apparatus containing light sources
    22 Supplementary requirements for apparatus incorporating
       non-sparking cells and batteries
       22.1 Categorization of cells and batteries
       22.2 General requirements for cells and batteries of
             types 1 and 2
       22.3 Charging of type 1 cells and batteries
       22.4 Charging of type 2 cells and batteries
    22.5 Requirements for type 3 secondary batteries
       22.6 Verification and tests
    23 Supplementary requirements for non-sparking low
       power apparatus
    24 Supplementary requirements for non-sparking current
       transformers
    25 Other electrical apparatus
    26 General supplementary requirements for apparatus
       producing arcs, sparks or hot surfaces
    27 Supplementary requirements for enclosed-break devices
       and non-incendive components producing arcs, sparks
       or hot surfaces
       27.1 Type testing
       27.2 Ratings
       27.3 Construction of enclosed-break devices
    28 Supplementary requirements for hermetically sealed
       devices producing arcs, sparks or hot surfaces
    29 Supplementary requirements for sealed devices or
       encapsulated devices producing arcs, sparks or hot
       surfaces
       29.1 Non metallic materials
       29.2 Opening
       29.3 Internal spaces
       29.4 Handling
       29.5 Resilient gasket and seals
       29.6 Encapsulating compounds
       29.7 Thickness of encapsulant
       29.8 Type tests
    30 Supplementary requirements for energy-limited apparatus
       and circuits producing arcs, sparks or hot surfaces
       30.1 General
       30.2 Associated energy-limited
             apparatus
       30.3 Energy-limited apparatus
       30.4 Self protected energy-limited apparatus
       30.5 Separation of conducting parts
       30.6 Plugs and sockets
       30.7 Protection against polarity reversal
       30.8 Requirements for components on which energy
             limitation depends
       30.9 Battery powered apparatus
       30.10 Marking and documentation
    31 Supplementary requirements for restricted-breathing
       enclosures protecting apparatus producing arcs, sparks
       or hot surfaces
       31.1 General
       31.2 Test point for restricted breathing apparatus
       31.3 Test point exemption
       31.4 Gasket and seal requirements
       31.5 Non-resilient seals
       31.6 Maintenance considerations
       31.7 Internal fans
    32 General information on verification and tests
    33 Type tests
       33.1 Representative samples
       33.2 Test configuration
       33.3 Tests for enclosures on which the type of
             protection depends
       33.4 Test for enclosed-break devices and non-incendive
             components
       33.5 Tests for sealed devices and encapsulated devices
       33.6 Assessment and test of energy-limited apparatus
             and circuits
       33.7 Tests for restricted-breathing enclosures
       33.8 Test for screw lampholders
       33.9 Test for starter holders for luminaires
       33.10 Tests for electronic starters for tubular
             fluorescent lamps and for ignitors for high
             pressure sodium or metal halide lamps
       33.11 Test for wiring of luminaires subject to
             high-voltage impulses from ignitors
       33.12 Mechanical shock test for batteries
       33.13 Insulation resistance test for batteries
       33.13 Insulation resistance test for batteries machines
    34 Routine verifications and tests
       34.1 General
       34.2 Specific routine tests
    35 Marking
       35.1 General
       35.2 Additional marking for batteries
       35.3 Examples of marking
    36 Documentation
    37 Instructions
    Bibliography
    Annex ZA (normative) Normative references to international
                           publications with their corresponding
                           European publications
    Annex ZZ (informative) Coverage of essential requirements of
                           the Directive
    Figures
    Tables

    Abstract - (Show below) - (Hide below)

    Describes requirements for the construction, testing and marking for Group II electrical apparatus with type of protection, "n" intended for use in explosive gas atmospheres.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes NBN EN 50021. (07/2005)
    Document Type Standard
    Publisher Belgian Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective