FOREWORD
Section 1 GENERAL
            Scope
            Referenced Standards
Section 2 METAL-ENCLOSED LOW-VOLTAGE POWER CIRCUIT
            BREAKER SWITCHGEAR
            Exceptions to American National Standard
            C.37.20.1-1993
Section 3 METAL-CLAD AND STATION-TYPE CUBICAL
            SWITCHGEAR
            Exceptions to American National Standard
            C37.20.2-1993
Section 4 METAL-ENCLOSED INTERRUPTER SWITCHGEAR
            Exceptions to American National Standard
            C37.20-3-1987(R1992)
Section 5 CONTROL SWITCHBOARDS
            Exceptions fo American National Standard
            C37.21-1995(R1991)
Section 6 METAL-ENCLOSED BUS AND CALCULATING LOSSES IN
            ISOLATED-PHASE BUS
            Exceptions to American National Standard
            C37.23-1987(R1991)
Section 7 GUIDE FOR EVALUATING THE EFFECTS OF SOLAR
            RADIATION ON OUTDOOR METAL-ENCLOSED SWITCH-
            GEAR
            Exceptions to American National Standard
            C37.24-1986(R1991)
Section 8 CONFORMANCE TESTING OF METAL-ENCLOSED LOW-
            VOLTAGE AC POWER CIRCUIT BREAKER SWITCHGEAR
            ASSEMBLIES
            Exceptions to American National Standard
            C37.51-1989(R1995)
Section 9 CONFORMANCE TESTING OF INDOOR AC HIGH-VOLTAGE
            CIRCUIT BREAKERS APPLIED AS REMOVABLE ELEMENTS
            IN METAL-ENCLOSED SWITCHGEAR ASSEMBLIES
            Exceptions to American National Standard
            C37.54-1987
Section 10 CONFORMANCE TESTING OF METAL-CLAD SWITCHGEAR
            ASSEMBLIES
            Exceptions to American National Standard
            C37.55-1989
Section 11 CONFORMANCE TESTING OF METAL-ENCLOSED
            INTERRUPTER SWITCHGEAR ASSEMBLIES
            Exceptions to American National Standard
            37.57-1990
Section 12 CONFORMANCE TESTING OF INDOOR AC MEDIUM-
            VOLTAGE SWITCHES FOR USE IN METAL-ENCLOSED
            SWITCHGEAR ASSEMBLIES
            Exceptions to American National Standard
            C37.58-1990
Section 13 DEFINITIONS FOR POWER SWITCH-GEAR
            Exceptions to American National Standard
            C37.100-1992

Covers low voltage power circuit breakers (1000 volts ac or less), low voltage power circuit breakers (3200 volts dc or less), and low voltage ac secondary network protectors. Includes the following sections: definitions for power switchgear; test procedures for low voltage ac power circuit protectors; enclosed field discharge circuit breakers for rotating electric machinery; application guide for low voltage ac non integrally fused power circuit breakers (using separately mounted current limiting fuses).

DocumentType
Standard
PublisherName
National Electrical Manufacturers Association
Status
Withdrawn

ANS 57.7-1988(R1997) DESIGN CRITERIA FOR AN INDEPENDENT SPENT FUEL STORAGE INSTALLATION (WATER POOL TYPE)
IEEE C37.121-2012 REDLINE IEEE Guide for Switchgear - Unit Substation - Requirements

IEEE C37.20.1-2015 IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear
ANSI C37.57 : 1990 SWITCHGEAR - METAL-ENCLOSED INTERRUPTER SWITCHGEAR ASSEMBLIES - CONFORMANCE TESTING
ANSI C37.51 : 1989 SWITCHGEAR - METAL-ENCLOSED LOW-VOLTAGE AC POWER - CIRCUIT BREAKER SWITCHGEAR ASSEMBLIES - CONFORMANCE TEST PROCEDURES
IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
ANSI C37.58 : 1990 INDOOR AC MEDIUM-VOLTAGE SWITCHES FOR USE IN METAL-ENCLOSED SWITCHGEAR - CONFORMANCE TEST PROCEDURES
ANSI C37.55 : 1989 MEDIUM VOLTAGE METAL-CLAD ASSEMBLIES - CONFORMANCE TEST PROCEDURES
IEEE C37.20.3-2013 REDLINE IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV)
ANSI C37.54 : 1996 FOR INDOOR ALTERNATING CURRENT HIGH-VOLTAGE CIRCUIT BREAKERS APPLIED AS REMOVABLE ELEMENTS IN METAL-ENCLOSED SWITCHGEAR ASSEMBLIES - CONFORMANCE TEST PROCEDURES
IEEE C37.24-2003 IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear
IEEE C37.21-2005 IEEE Standard for Control Switchboards
IEEE C37.23-2003 IEEE Standard for Metal-Enclosed Bus

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.