NEN EN 50131-2-4 : 2008
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS
01-08-2020
12-01-2013
Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
3.1 Definitions
3.2 Abbreviations
4 Functional requirements
4.1 Indication signals or messages
4.2 Detection
4.3 Operational requirements
4.4 Immunity of the individual technologies to incorrect
operation
4.5 Tamper security
4.6 Electrical requirements
4.7 Environmental classification and conditions
5 Marking, identification and documentation
5.1 Marking and/or identification
5.2 Documentation
6 Testing
6.1 General test conditions
6.2 Basic detection test
6.3 Walk testing
6.4 Switch-on delay, time interval between signals and
indication of detection
6.5 Self tests
6.6 Immunity of individual technologies to incorrect operation
6.7 Tamper security
6.8 Electrical tests
6.9 Environmental classification and conditions
6.10 Marking, identification and documentation
Annexes
Annex A (normative) Dimensions & Requirements of the standardised
Test Magnets
Annex B (normative) General testing matrix
Annex C (normative) Walk test diagrams
Annex D (normative) Procedure for calculation of the average
temperature difference between the standard target and the
background
Annex E (informative) Basic detection target for the basic test of
detection capability
Annex F (informative) Equipment for walk test velocity control
Annex G (informative) Immunity to visible and near Infrared
radiation - Notes on calibration of the light source
Annex H (informative) Immunity to microwave signal interference by
fluorescent lights
Annex I (informative) Example list of small tools
Annex J (informative) Test for resistance to re-orientation of
adjustable mountings
Details combined passive infrared and microwave detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV.
DevelopmentNote |
Supersedes NEN NPR CLC/TS 50131-2-4. (02/2008)
|
DocumentType |
Standard
|
PublisherName |
Netherlands Standards
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
BS EN 50131-2-4:2008 | Identical |
NF EN 50131-2-4 : 2008 | Identical |
I.S. EN 50131-2-4:2008 | Identical |
DIN EN 50131-2-4 : 2008 | Identical |
EN 50131-2-4:2008 | Identical |
Access your standards online with a subscription