1 Domaine d'application
  1.1 Émission
  1.2 Immunité
2 Références normatives
3 Définitions
4 Montage pour essai d'émission et d'immunité
  4.1 Exigences générales
  4.2 Équipements auxiliaires
  4.3 Équipements de mesurage
5 Essais d'émission à haute fréquence
  5.1 Conditions d'essai
  5.2 Valeurs limites d'émission
      5.2.1 Généralités
      5.2.2 Valeurs limites d'émission conduite
Tableau 1 - Valeurs limites de la tension perturbatrice pour
            l'accès d'entrée de puissance en courant alternatif
            pour les appareils de classe A dans la bande de
            fréquence comprise entre 150 kHz et 30 MHz
Tableau 2 - Valeurs limites de la tension perturbatrice pour
            l'accès d'entrée de puissance en courant alternatif
            pour les appareils de classe B dans la bande de
            fréquence comprise entre 150 kHz et 30 MHz
      5.2.3 Valeurs limites d'émissions rayonnées
6 Essais d'émission à basse fréquence
7 Essais d'immunité
Tableau 3 - Niveaux d'immunité - Enveloppe
Tableau 4 - Niveaux d'immunité - Accès d'entrée de puissance en
            courant alternatif
Tableau 5 - Niveaux d'immunité - Accès de lignes de processus,
            de mesure et de commande
  7.1 Conditions d'essai
  7.2 Critères de performance d'immunité
      7.2.1 Critère de performance A
      7.2.2 Critère de performance B
      7.2.3 Critère de performance C
  7.3 Niveaux d'immunité
8 Documentation pour l'acheteur/l'utilisateur
Annexe A (informative) Niveaux d'immunité - Accès d'entrée de
                       puissance en courant alternatif
Tableau A.1 - Niveaux d'immunité - Accès d'entrée de puissance
              en courant alternatif

Pertains to equipment for resistance welding and allied processes intended for use in industrial and light industrial environments which are connected to mains supplies with rated voltages up to 1 000 V a.c. rms. This standard does not define safety requirements.

DevelopmentNote
Indice de classement: C91-200 PR NF EN 50240 October 2003 (10/2003)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
BS EN 50240:2004 Identical
EN 50240:2004/corrigendum:2005 Identical
NBN EN 50240 : 2005 Identical
NEN EN 50240 : 2004 C1 2006 Identical
SN EN 50240 : 2004 Identical
DIN EN 50240 : 2005 Identical
UNE-EN 50240:2004 Identical
I.S. EN 50240:2006 Identical

CISPR 14-1:2016 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
NF EN 61000-2-4 : 2003 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
IEC 61000-2-4:2002 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
NF EN 61000-3-2 : 2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
NF EN 61000 4-2 : 2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-2: TESTING AND MEASUREMENT TECHNIQUES - ELECTROSTATIC DISCHARGE IMMUNITY TEST
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
NF EN 61000-4-4 : 2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
NFC 91 016-1 : 2001 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS
NF EN 61000-3-3 : 2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
NF EN 61000-4-7 : 2003 AMD 1 2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO
NF EN 61000 4-15 : 2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-15: TESTING AND MEASUREMENT TECHNIQUES - FLICKERMETER - FUNCTIONAL AND DESIGN SPECIFICATIONS
UTEC 91 003-4 : 1999 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-4: LIMITS - LIMITATION OF EMISSION OF HARMONIC CURRENTS IN LOW-VOLTAGE POWER SUPPLY SYSTEMS FOR EQUIPMENT WITH RATED CURRENT GREATER THAN 16 A
NF EN 61000-3-11 : 2001 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-11: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS - EQUIPMENT WITH RATED CURRENT BELOW OR EQUAL TO 75 A AND SUBJECT TO CONDITIONAL CONNECTION
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC TS 61000-3-4:1998 Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A
ISO 669:2016 Resistance welding Resistance welding equipment Mechanical and electrical requirements
NF EN 61000 4-6 : 2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
NF EN 61000-4-3 : 2006 AMD 2 2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
NF EN 61000-4-11 : 2004 AMD 1 2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS
NFC 01 161 : 2016 AMD 1 2017 INTERNATIONAL ELECTROTECHNICAL VOCABULARY - PART 161: ELECTROMAGNETIC COMPATIBILITY
IEC 60050-851:2008 International Electrotechnical Vocabulary (IEV) - Part 851: Electric welding
CISPR 16-1:1999+AMD1:2002 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
NF EN 55014-1 : 2017 ELECTROMAGNETIC COMPATIBILITY - REQUIREMENTS FOR HOUSEHOLD APPLIANCES, ELECTRIC TOOLS AND SIMILAR APPARATUS - PART 1: EMISSION
NF EN 50063 : 1990 SAFETY REQUIREMENTS FOR THE CONSTRUCTION AND THE INSTALLATION OF EQUIPMENT FOR RESISTANCE WELDING AND ALLIED PROCESSES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.