• NF EN 54-7 : 2001 AMD 2 2006

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION

    Available format(s): 

    Superseded date:  25-07-2019

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Avant-propos
    1 Domaine d'application
    2 Références normatives
    3 Termes et définitions
    4 Exigences
      4.1 Conformité
      4.2 Indication individuelle d'alarme
      4.3 Raccordement de dispositifs auxiliaires
      4.4 Surveillance des détecteurs à tête amovible
      4.5 Moyens de calibrage
      4.6 Réglage sur site de la sensibilité de fonctionnement
      4.7 Protection contre la pénétration de corps étrangers
      4.8 Réponse aux foyers à évolution lente
      4.9 Marquage
      4.10 Documentation
      4.11 Exigences complémentaires pour les détecteurs utilisant un
           logiciel
    5 Essais
      5.1 Généralités
      5.2 Reproductibilité
      5.3 Influence de la direction
      5.4 Dispersion d'exemplaires
      5.5 Variation des paramètres d'alimentation électrique
      5.6 Influence des courants d'air
      5.7 Influence de la lumière artificielle
      5.8 Chaleur sèche (Essai fonctionnel)
      5.9 Froid (Essai fonctionnel)
      5.10 Chaleur humide continue (Essai fonctionnel)
      5.11 Chaleur humide continue (Essai d'endurance)
      5.12 Corrosion par le dioxyde de soufre (SO2) (Essai d'endurance)
      5.13 Choc (Essai fonctionnel)
      5.14 Impact (Essai fonctionnel)
      5.15 Vibration sinusoïdale (Essai fonctionnel)
      5.16 Vibration sinusoïdale (Essai d'endurance)
      5.17 Compatibilité électromagnétique (CEM), essais d'immunité (Essai
           fonctionnel)
      5.18 Sensibilité sur foyers types
    Annexe A (normative) Tunnel de fumée pour les mesures du seuil de
                           réponse
    Annexe B (normative) Produit d'aérosol d'essai pour la mesure des
                           valeurs du seuil de réponse
    Annexe C (normative) Instruments de mesure de la fumée
    Annexe D (normative) Appareil d'essai d'éclats
    Annexe E (informative) Appareil pour l'essai d'impact
    Annexe F (normative) Local d'essai feu
    Annexe G (normative) TF2 - Feu de bois à combustion lente (pyrolyse)
    Annexe H (normative) TF3 - Feu de coton à combustion lente
    Annexe I (normative) TF4 - Feu de matières plastiques inflammables
                           (polyuréthanne)
    Annexe J (normative) TF5 - Feu de liquide inflammable (n-heptane)
    Annexe K (informative) Information relative à la construction du tunnel
                           de fumée
    Annexe L (informative) Information relative aux exigences de la réponse
                           aux feux à développement lent
    Annexe M (informative) Information relative à la construction de la
                           chambre de mesure d'ionisation

    Abstract - (Show below) - (Hide below)

    Deals in requirements, test methods and performance criteria for point smoke detectors that operate using scattered light, transmitted light or ionization, for use in fire detection and fire alarm systems for buildings.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de Classement: S61-987PR. Supersedes NFS 61 954 and NFS 61 956. (05/2001) PR NF EN 54-7 May 2011. (05/2011)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Superseded
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    NFS 61 961 : 2007 FIRE DETECTION EQUIPMENT - ACTUATING DETECTOR SYSTEMS
    NFS 61 023 : 2004 XP FIRE DETECTION SYSTEMS (FDS) USING RADIO LINKS

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 209-1:1989 Wrought aluminium and aluminium alloys Chemical composition and forms of products Part 1: Chemical composition
    NF EN 54-1 : 2011 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 1: INTRODUCTION
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
    NF EN 60068-2-1 : 2007 ENVIRONMENTAL TESTING - PART 2-1: TESTS - TESTS A: COLD
    NF EN 60068-1 : 2014 ENVIRONMENTAL TESTING - PART 1: GENERAL AND GUIDANCE
    NF EN 50130-4 : 2014 AMD 1 2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    NF EN 60068 2-6 : 2008 ENVIRONMENTAL TESTING - PART 2-6: TESTS - TEST FC: VIBRATION (SINUSOIDAL)
    NF EN 60068 2-27 : 2009 ENVIRONMENTAL TESTING - PART 2-27: TESTS - TEST EA AND GUIDANCE: SHOCK
    IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    IEC 60068-2-56:1988 Environmental testing - Part 2: Tests. Test Cb: Damp heat, steady state, primarily for equipment