• NF EN 60565 : 2007

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    UNDERWATER ACOUSTICS - HYDROPHONES - CALIBRATION IN THE FREQUENCY RANGE 0,01 HZ TO 1 MHZ

    Available format(s): 

    Superseded date:  05-10-2021

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviated terms
    5 Procedures for calibrations
       5.1 Principles
       5.2 Field limitations
       5.3 Schematic survey of procedures
       5.4 Reporting of results
       5.5 Recalibration periods
       5.6 Temperature and pressure considerations for
             calibration
    6 Preparation of transducers
       6.1 Wetting
       6.2 Hydrophone support
       6.3 Influence of cable
    7 Electrical measurements
       7.1 Signal type
       7.2 Earthing
       7.3 Measurement of hydrophone output voltage
       7.4 Measurement of projector current
       7.5 Measurement of transfer impedance
    8 Free-field reciprocity calibration
       8.1 General principle
       8.2 Theory
       8.3 Separation distance
       8.4 Minimum distance from transducers to boundary surface
       8.5 Frequency limitation
       8.6 Measurements and checks
       8.7 Uncertainty
    9 Free-field calibration by comparison
       9.1 Principle
       9.2 Comparison with a standard hydrophone
       9.3 Calibration with a calibrated projector
    10 Calibration by hydrostatic excitation
       10.1 Principle
       10.2 Determination of equivalent pressure
       10.3 Measurement of the sensitivity of hydrophones
       10.4 Design of vibration system
       10.5 Uncertainty
       10.6 Alternative method for hydrostatic excitation
    11 Calibration by piezoelectric compensation
       11.1 Principle
       11.2 Procedure
       11.3 Design of the calibration chamber
       11.4 Practical limitations of the piezoelectric
             compensation method
       11.5 Uncertainty
    12 Acoustic coupler reciprocity calibration
       12.1 Principle
       12.2 Procedure
       12.3 Theory
       12.4 Acoustic compliance
       12.5 High-frequency limit
       12.6 Low-frequency limit
       12.7 Measurement
       12.8 Uncertainty
       12.9 Limitations
       12.10 Acoustic-coupler calibration using a reference
             coupler with two reciprocal transducers and an
             auxiliary coupler with the same two transducers
             and a hydrophone to be calibrated
       12.11 Acoustic-coupler calibration using a reference coupler
             with two reciprocal transducers and an auxiliary
             coupler with the same two transducers, a hydrophone
             to be calibrated, and a sound source
       12.12 Acoustic-coupler calibration using a coupler,
             a reciprocal transducer, a projector, a hydrophone
             to be calibrated, and a subsidiary body of known
             compliance
    13 Calibration with a pistonphone
       13.1 Principle
       13.2 Procedure
       13.3 Limitations
       13.4 Uncertainty
    14 Calibration with a vibrating column
       14.1 Principle
       14.2 Procedure
       14.3 Expression for the pressure
       14.4 Determination of the sensitivity
       14.5 Conditions of measurement
       14.6 Uncertainty
    Annex A (informative) Directional response of a hydrophone
    Annex B (informative) Electrical loading corrections
    Annex C (informative) Pulsed techniques in free-field
                          calibrations
    Annex D (informative) Assessment of uncertainty in the
                          calibration of hydrophones
    Annex E (informative) Equivalent circuit of the excitation
                          system for calibration with a vibrating
                          column
    Annex ZA (normative) Normative references to international
                         publications with their corresponding
                         European publications
    Bibliography

    Abstract - (Show below) - (Hide below)

    Specifies methods for calibration of hydrophones or reversible transducers when used as a hydrophone, particularly in the frequency range from 0,01 Hz to 1 MHz. Rules for the presentation of the calibration data are established.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de classement: C97-915 PR NF EN 60565 November 2004. (11/2004)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    NF EN 62127-1 : 2008 AMD 1 2013 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ
    NF EN 62127-2 : 2008 AMD 2 2017 ULTRASONICS - HYDROPHONES - PART 2: CALIBRATION FOR ULTRASONIC FIELDS UP TO 40 MHZ

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60050-801:1994 International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics
    NFC 01 801 : 1999 ELECTROTECHNICAL VOCABULARY - CHAPTER 801: ACOUSTICS AND ELECTRO ACOUSTICS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective