• Shopping Cart
    There are no items in your cart

NF EN 60811 1-2 : 96 AMD 2 2001

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 2: THERMAL AGEING METHODS

Superseded date

12-11-2016

Published date

12-01-2013

Sorry this product is not available in your region.

AVANT-PROPOS
1 Domaine d'application
2 Valeurs prescrites pour les essais
3 Application
4 Essais de type et autres essais
5 Préconditionnement
6 Température d'essai
7 Valeur médiane
8 Méthodes de vieillissement thermique
  8.1 Vieillissement en étuve air
  8.2 Vieillissement dans la bombe à air
  8.3 Vieillissement dans la bombe à oxygène
  8.4 Méthodes de mesure du débit d'air dans les étuves
Figures
Annexe A Correspondance entre les articles et paragraphes
des Publications 538 et 540 de la CEI et de la Publication
811 de la CEI
Annexe ZA (normative) Autres publications internationales citées dans
la présente norme avec les références des publications
européennes correspondantes

Ce document précise les modalités des essais de vieillissement thermique effectués sur les enveloppes isolantes et les gaines des conducteurs et câbles électriques. La présente norme précise les méthodes d'essais à employer pour l'essai des matériaux polymères d'isolation et de gainage des câbles électriques pour la distribution d'énergie et les télécommunications, y compris les câbles utilisés à bord des navires. Cette section deux de la première partie donne les méthodes de vieillissement thermique qui s'appliquent aux types les plus courants de mélanges des isolants et des gaines (élastomères, PVC, PE, PP, etc.).

DevelopmentNote
Indice de classement: C32-025 Supersedes NFC 32 025 (09/2001)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 60811-1-2:1985 Identical
EN 60811-1-2:1995/A2:2000 Identical

NF EN 50290-2-21 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATION COMPOUNDS
NFC 32 331 : 2002 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CABLES FOR SUPPLY LEADS FOR HEATING EQUIPMENT BY MEANS OF HEATING CABLE FOR EMBEDDING IN WALLS OF BUILDING
NFC 32 207 : 1996 AMD 1 2009 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - POLYVINYL CHLORIDE INSULATED CABLES COVERED WITH A LIGHT POLYVINYL CHLORIDE SHEATH, OF RATED VOLTAGE 300/500 V - SERIES OF THE NATIONAL TYPE
NF EN 61138 : 2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
NF EN 60811 3-2 : 1996 AMD 2 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3: METHODS SPECIFIC TO PVC COMPOUNDS - SECTION 2: LOSS OF MASS TEST - THERMAL STABILITY TEST
NFC 33 062 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SF6 INSULATED METAL ENCLOSED TERMINATIONS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
NFC 33 252 : 2002 TESTS FOR POWER CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30kV (Um=36kV) UP TO 150 kV (Um=170kV)
UTEC 32 502 : 2008 AMD 1 2010 GUIDE FOR PHOTOVOLTAIC DEVICE CABLES
NF EN 50396 : 2005 AMD 1 2012 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
NFC 32 332 : 2002 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CABLES FOR SUPPLY LEADS WITH METALLIC COVERING FOR HEATING EQUIPMENT BY MEANS OF HEATING CABLES, WITH METALLIC COVERING, FOR EMBEDDING IN WALLS OF BUILDING
NF EN 50264-3-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
NFC 33 253 : 2006 INSULATED CABLES FOR POWER SYSTEMS - SINGLE-CORE CABLES WITH POLYMERIC INSULATION FOR RATED VOLTAGES ABOVE 150 KV (UM = 170 KV) UP TO 500 KV (UM = 525 KV)
NFC 32 334 : 2002 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CABLES FOR SUPPLY LEADS WITH LOW ELECTROMAGNETIC RADIATIONS FOR HEATING EQUIPMENT BY MEANS OF HEATING CABLES, WITH METALLIC COVERING, FOR EMBEDDING IN WALLS OF BUILDING
NF EN 50497 : 2008 RECOMMENDED TEST METHOD FOR ASSESSMENT OF THE RISK OF PLASTICIZER EXUDATION FROM PVC INSULATED AND SHEATHED CABLES
NF EN 50382-2 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
NF EN 50290-2-27 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS
NF EN 50290-2-22 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS
NF EN 50305 : 2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - TEST METHODS
NF EN 50290-2-26 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS
NF EN 50264-2-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
NF EN 50290-2-24 : 2002 AMD 1 2009 COMMUNICATION CABLES - PART 2-24: COMMON DESIGN RULES AND CONSTRUCTION - PE SHEATHING
NF EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
NF EN 50264-3-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
NFC 33 061 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - JOINTS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
NF EN 50306-1 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS
NF EN 50264-2-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
NF EN 61442 : 2005 TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 36 KV (UM = 42 KV)