• Shopping Cart
    There are no items in your cart

NFC 32 330 : 2002

Current

Current

The latest, up-to-date edition.

INSULATED CABLES AND CORDS FOR INSTALLATIONS AND EQUIPMENT - HEATING EQUIPMENT BY MEANS OF HEATING CABLES FOR EMBEDDING INTO WALLS OF BUILDINGS

Published date

12-01-2013

Sorry this product is not available in your region.

AVANT-PROPOS
I GÉNÉRALITÉS
1 DOMAINE D'APPLICATION
2 RÉFÉRENCES NORMATIVES
3 MODALITÉS D'APPLICATION
4 DÉFINITIONS
5 CLASSIFICATION DES ÉLÉMENTS DE CHAUFFAGE
6 DÉSIGNATION
7 MARQUES ET INDICATIONS
8 REPÉRAGE DES CONDUCTEURS DES LIAISONS FROIDES ET
   DE PROTECTION
II CARACTÉRISTIQUES DES CABLES CHAUFFANTS
A. Câbles isolés en matière organique
9 CONSTITUTION
10 CARACTÉRISTIQUES DE L'AME CONDUCTRICE
11 CARACTÉRISTIQUES DE L'ENVELOPPE ISOLANTE
12 CARACTÉRISTIQUES DE LA GAINE INTERNE
13 CARACTÉRISTIQUES DU REVETEMENT MÉTALLIQUE
14 CARACTÉRISTIQUES DE LA GAINE EXTERNE
B. Câbles à isolant minéral
15 CONSTITUTION
16 CARACTÉRISTIQUES DE L'AME CONDUCTRICE
17 CARACTÉRISTIQUES DE L'ISOLANT MINÉRAL
18 CARACTÉRISTIQUES DE LA GAINE EN CUIVRE
19 CARACTÉRISTIQUES DE LA GAINE EXTERNE
C. Caractéristiques des câbles complets
20 TEMPÉRATURE SPÉCIFIÉE DES CABLES
21 RÉSISTANCE D'ISOLEMENT
22 RIGIDITÉ DIÉLECTRIQUE
23 RÉSISTANCE MÉCANIQUE
24 COMPATIBILITÉ DES CONSTITUANTS
D. Modalités des essais
25 GÉNÉRALITÉS SUR LES ESSAIS
26 RÉSISTANCE LINÉIQUE
27 COEFFICIENT DE TEMPÉRATURE
28 VÉRIFICATION DE L'ÉPAISSEUR DE L'ISOLANT MINÉRAL
29 VÉRIFICATION DU DIAM?TRE SUR LA GAINE EN CUIVRE ET DE
   L'ÉPAISSEUR DE LA GAINE EN CUIVRE DES CABLES A ISOLANT MINÉRAL
30 VÉRIFICATION DE LA RÉSISTANCE D'ISOLEMENT
31 VÉRIFICATION DE LA RIGIDITÉ DIÉLECTRIQUE
32 ESSAI DE TRACTION
33 ESSAI DE COMPRESSION DES CABLES ISOLÉS EN MATIERE ORGANIQUE
34 ESSAI D'APLATISSEMENT DES CABLES A ISOLANT MINÉRAL
35 ESSAI D'ENROULEMENTS ALTERNÉS
36 ESSAI DE PÉNÉTRATION A TRAVERS LE REV?TEMENT MÉTALLIQUE
III CARACTÉRISTIQUES DES ÉLÉMENTS DE CHAUFFAGE
37 CARACTÉRISTIQUES DES LIAISONS FROIDES ET DES CONDUCTEURS
   DE PROTECTION
38 VÉRIFICATION DE LA PUISSANCE ABSORBÉE
39 RÉSISTANCE A L'HUMIDITÉ
40 RÉSISTANCE MÉCANIQUE
41 RACCORDEMENT INTERMÉDIAIRE ENTRE LES ÉLÉMENTS DE CHAUFFAGE,
   MONTÉS EN SÉRIE
42 ISOLEMENT ÉLECTRIQUE

La présente norme s'applique aux équipements de chauffage réalisés à partir des câbles chauffants monoconducteurs revêtus d'un revêtement métallique, de tension assignée 300/500 V et des liaisons froides appropriées, destinés à être incorporés dans les parois des bâtiments. Les conducteurs nus ou légèrement isolés au sens de la norme NF C 15-100 ne sont pas visés dans la présente norme. La présente norme s'applique aux câbles suivants:- câbles isolés en matière organique, avec revêtement métallique n'assurant pas une protection mécanique,- câbles isolés en matière organique, avec revêtement métallique assurant une protection mécanique,- câbles isolés en matière minérale, dits <>. La présente norme a pour but de définir les caractéristiques et règles de construction auxquelles doivent satisfaire:- les câbles chauffants monoconducteurs revêtus d'un revêtement métallique, utilisés dans la réalisation des éléments de chauffage,- les éléments de chauffage destinés à être incorporés dans les parois des bâtiments, réalisés à partir des câbles définis ci-dessus, ainsi que les essais auxquels doivent satisfaire chacun de ces matériels pris séparément. Elle indique notamment les caractéristiques et règles nécessaires pour assurer la sécurité des personnes et des biens et d'une manière plus générale pour assurer une aptitude à l'emploi satisfaisante, sous réserve d'une installation conforme à la norme NF C 15-100 et à la norme NF P 52-302 (anciennement DTU 65-7).

DevelopmentNote
Indice de Classement: C32-330 PR NFC 32 330 MARCH 2002 (02/2002)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

NFC 32 332 : 2002 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CABLES FOR SUPPLY LEADS WITH METALLIC COVERING FOR HEATING EQUIPMENT BY MEANS OF HEATING CABLES, WITH METALLIC COVERING, FOR EMBEDDING IN WALLS OF BUILDING
NFP 52 302 : 1999 BUILDING WORKS - EXECUTION OF FLOOR HEATING THROUGH ELECTRIC CABLES SET IN CONCRETE - PART 1: TECHNICAL SPECIFICATIONS - PART 2: SPECIAL CLAUSES
NFC 32 335 : 2003 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - HEATING CABLES, WITHOUT MECHANICAL PROTECTION AND REDUCED CROSS SECTIONAL AREA

NFC 32 090 : 84 AMD 2 93 INSULATED CABLES AND FLEXIBLE CORDS FOR ELECTRIC POWER AND LIGHTING - EXTRUDED SOLID DIELECTRIC INSULATED CABLES OF RATED VOLTAGE UP TO AND INCLUDING 600/1 000 V
NFP 52 302-1 : 93 AMD 1 99 BUILDING WORKS - EXECUTION OF FLOOR HEATING THROUGH ELECTRIC CABLES SET IN CONCRETE - PART 1: TECHNICAL SPECIFICATIONS
NFC 32 102-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 1: GENERAL REQUIREMENTS
NF EN 50102 : 95 AMD 1 99 DEGRES DE PROTECTION PROCURES PAR LES ENVELOPPES DE MATERIELS ELECTRIQUES CONTRE LES IMPACTS MECANIQUES EXTERNES (CODE IK)
NFC 32 050 : 1990 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - METAL SHEATHED CABLES - RULES
NFC 30 204 : 88 AMD 1 1991 INSULATED CABLES AND FLEXIBLE CORDS - MARKING OF CABLES
NFC 32 332 : 2002 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CABLES FOR SUPPLY LEADS WITH METALLIC COVERING FOR HEATING EQUIPMENT BY MEANS OF HEATING CABLES, WITH METALLIC COVERING, FOR EMBEDDING IN WALLS OF BUILDING
1973/23/EEC : 1973 COUNCIL DIRECTIVE OF 19 FEBRUARY 1973 ON THE HARMONIZATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS
NFC 32 201-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS
NFC 01 461 : 2008 INTERNATIONAL ELECTROTECHNICAL VOCABULARY - PART 461: ELECTRIC CABLES
NFC 68 105 : 1990 CONDUITS AND FITTINGS FOR ELECTRICAL INSTALLATIONS - CIRCULAR CROSS-SECTION, INSULATING, PLIABLE, DEFORMABLE, SELF RECOVERING CONDUITS - TYPE ICD AND ICT
NFC 32 013 : 1981 INSULATED CABLES AND FLEXIBLE CORDS - CONDUCTORS OF INSULATED CABLES
NFC 32 070 : 2001 AMD 1 2005 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CLASSIFICATION TESTS ON CABLES AND CORDS WITH RESPECT TO THEIR BEHAVIOUR TO FIRE
NFA 03 010 : 1986 METALLIC MATERIALS - WIRE - REVERSE BEND TEST
NFP 52 302-2 : 1993 BUILDING WORKS - EXECUTION OF FLOOR HEATING THROUGH ELECTRIC CABLES SET IN CONCRETE - PART 2: SPECIAL CLAUSES
UTEC 32 014 : 83 AMD 1 92 GUIDE FOR CHECKING CONDUCTORS CHARACTERISTICS
UTEC 15 720 : 1975 LOW-VOLTAGE INSTALLATIONS AND CORRESPONDING EQUIPMENT - ELECTRICAL HEATING EQUIPMENT FOR ROOMS. SAFETY REQUIREMENTS - PROVISIONAL REQUIREMENTS.
NFC 15 100 : 2002 AMD 5 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.