Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Application. 1.4 Retroactivity. 1.5 Equivalency. 1.6 Units and Formulas. Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. 2.3 Other Publications. 2.4 References for Extracts in Mandatory Sections. Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. Chapter 4 System Components and System Types 4.1 General. 4.2 Water Supplies. 4.3 Foam Concentrates. 4.4 Concentrate Compatibility. 4.5 Foam Proportioning. 4.6 Foam Concentrate Pumps. 4.7 Piping. 4.8 System Types. 4.9 Operation and Control of Systems.Chapter 5 Low-Expansion Foam Tank, Fueling, and Spill Area Systems 5.1 Types of Hazards. 5.2 Outdoor Fixed-Roof (Cone) Tanks. 5.3 Outdoor Open-Top Floating Roof Tanks. 5.4 Outdoor Covered (Internal) Floating Roof Tanks. 5.5 Indoor Hazards. 5.6 Loading Racks. 5.7 Diked Areas — Outdoor. 5.8 Nondiked Spill Areas. 5.9 Supplementary Protection. Chapter 6 Low-Expansion Foam Sprinkler and Spray Systems 6.1 Administration. 6.2 General System Requirements. 6.3 Working Plans. 6.4 System Components. 6.5 System Design and Installation. 6.6 Acceptance Tests. 6.7 Inspection, Testing, and Maintenance. Chapter 7 Medium- and High-Expansion Systems 7.1 General Information and Requirements. 7.2 Use and Limitations. 7.3 Hazards Protected. 7.4 Types of Systems. 7.5 Systems Protecting One or More Hazards. 7.6 Occupant Safety. 7.7 Operation and Control of Systems. 7.8 Foam Concentrate. 7.9 Air Supply. 7.10 Foam-Generating Apparatus Location.7.11 Distribution Systems. 7.12 Total Flooding Systems General Information. 7.13 Local Application Systems. 7.14 Foam Applications for Liquefied Natural Gas (LNG). 7.15 Portable Foam-Generating Devices. Chapter 8 Compressed Air Foam Systems 8.1 General. 8.2 Water Supplies. 8.3 Foam Concentrate. 8.4 Air or Nitrogen Supply. 8.5 Compressed Air Foam-Generating Method. 8.6 Distribution Systems. 8.7 Compressed Air Foam Discharge Devices. 8.8 Operation and Control of Systems. 8.9 System Types. 8.10 Limitations. 8.11 System Design. 8.12 Installation of Piping and Fittings. 8.13 Installation of Automatic Detection. 8.14 CAFS Discharge Device Choice and Location. 8.15 Discharge Density. 8.16 Discharge Duration. 8.17 System Flow Calculation. 8.18 Plans and Specifications. 8.19 Testing and Acceptance. 8.20 Maintenance. Chapter 9 Specifications and Plans 9.1 Approval of Plans. 9.2 Specifications.9.2 Specifications. 9.3 Plans. Chapter 10 Installation Requirements 10.1 Foam Concentrate Pumps. 10.2 Flushing. 10.3 Power Supply. 10.4 Low-Expansion System Piping. 10.5 Valves in Low-Expansion Systems. 10.6 Hangers, Supports, and Protection for Pipework. 10.7 Hose Requirements. 10.8 Test Connections. Chapter 11 Low-Expansion Foam Systems for Marine Applications 11.1 General. 11.2 Fixed Low-Expansion Foam Systems for Machinery Spaces. 11.3 Fixed Low-Expansion Foam Systems on Deck for Petroleum and Chemical Tankers. 11.4 Foam Outlet Devices. 11.5 Monitors. 11.6 Hand Hoselines. 11.7 Hydraulic Calculations. 11.8 Isolation Valves. 11.9 Hangers, Supports, and Protection of Pipework. 11.10 Testing and Inspection. 11.11 Foam System Concentrate Storage. 11.12 Supply Arrangements. 11.13 Piping Materials. Chapter 12 Acceptance Testing 12.1 Inspection and Visual Examination. 12.2 Flushing after Installation. 12.3 Acceptance Tests.12.4 Pressure Tests. 12.5 Operating Tests. 12.6 Discharge Tests. 12.7 Approval of Low-, Medium-, and High-Expansion Foam Systems. 12.8 System Restoration. 12.9 Acceptance Tests of Foam-Water Deluge and Spray Systems. Chapter 13 Inspection, Testing, and Maintenance 13.1 General. Annex A Explanatory Material Annex B Storage Tank Protection Summary Annex C Medium- and High-Expansion Foam Annex D Tests for Foam Systems Annex E Foam Health, Safety, and Environmental Issues Annex F Test Method for Marine Firefighting Foam Concentrates Protecting Hydrocarbon Hazards Annex G Foam Concentrate Quality Annex H Synthetic Fluorine-Free Foam (SFFF) Research Testing Annex I Rim Seal Fire Test Protocol Annex J Informational References
This standard shall provide the minimum requirements for the design and installation of foam systems.
DocumentType |
Standard
|
Pages |
159
|
PublisherName |
National Fire Protection Association
|
Status |
Current
|
Supersedes |
NFPA 418:2024 | Standard for Heliports and Vertiports |
NFPA 13:2025 | Standard for the Installation of Sprinkler Systems |
PIP VEETA001:2024 | Tank Selection Guide |
NFPA 33:2024 | Standard for Spray Application Using Flammable or Combustible Materials |
NFPA 72:2022 | National Fire Alarm and Signaling Code |
NFPA 220:2024 | Standard on Types of Building Construction |
NFPA 24 : 2013 | INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES |
NFPA 25 : 2017 | INSPECTION, TESTING, AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS |
NFPA 70 : 2014 | NATIONAL ELECTRICAL CODE |
NFPA 30:2021 | Flammable and Combustible Liquids Code |
NFPA 15 : 2017 | WATER SPRAY FIXED SYSTEMS FOR FIRE PROTECTION |
NFPA 1900:2024 | Standard for Aircraft Rescue and Fireghting Vehicles, Automotive Fire Apparatus, Wildland Fire Apparatus, and Automotive Ambulances |
NFPA 1150:2022 | Standard on Foam Chemicals for Fires in Class A Fuels |
NFPA 22 : 1998 | WATER TANKS FOR PRIVATE FIRE PROTECTION |
NFPA 1963 : 2019 | Standard for Fire Hose Connections |
NFPA 20 : 2016 | INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION |
NFPA 13 : 2002 | INSTALLATION OF SPRINKLER SYSTEMS |
NFPA 409:2022 | Standard on Aircraft Hangars |