Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Application. 1.4 Retroactivity. 1.5 Equivalency. 1.6 Units and Formulas. Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. 2.3 Other Publications. 2.4 References for Extracts in Mandatory Sections. Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. Chapter 4 General Requirements 4.1 Design Objectives. 4.2 Special Considerations. 4.3 Qualifications. 4.4 Control of Runoff. 4.5 Flammable and Combustible Liquids.Chapter 5 System Components 5.1 General. 5.2 Water Spray Nozzles. 5.3 Pipe and Tube. 5.4 Fittings. 5.5 Joining of Pipe and Fittings. 5.6 Hangers. 5.7 Valves. 5.8 Pressure Gauges. 5.9 Strainers. 5.10 Fire Department Connections. 5.11 Alarms. 5.12 Detection Systems. Chapter 6 Installation Requirements 6.1 Basic Requirements. 6.2 Water Spray Nozzles. 6.3 Piping Installation. 6.4 System Attachments. 6.5 Automatic Detection Equipment. Chapter 7 Design Objectives 7.1 System Design. 7.2 Extinguishment. 7.3 Control of Burning. 7.4 Exposure Protection. 7.5 Flammable Vapor Mitigation. 7.6 Combined Systems. 7.7 Automatic Detection Equipment.Chapter 8 Plans and Hydraulic Calculations 8.1 General. 8.2 Working Plans. 8.3 Hydraulic Calculations. 8.4 Water Supply Information. 8.5 Hydraulic Calculation Procedures. Chapter 9 Water Supplies 9.1 General. 9.2 Volume and Pressure. 9.3 Acceptable Water Supply Systems. Chapter 10 System Acceptance 10.1 Certification. 10.2 Flushing of Supply Pipe. 10.3 Hydrostatic Pressure Tests. 10.4 Operating Tests. 10.5 Hydraulic Design Information Sign. 10.6 General Information Sign. Chapter 11 System Inspection, Testing, and Maintenance 11.1 General. Chapter 12 Ultra-High-Speed Water Spray Systems 12.1 General. 12.2 Response Time. 12.3 Design Considerations. 12.4 System Acceptance. 12.5 Testing and Maintenance. Annex A Explanatory Material Annex B Hydraulic Calculations Annex C Informational References


This standard provides the minimum requirements for the design, installation, and system acceptance testing of water spray fixed systems for fire protection service and the minimum requirements for the periodic testing and maintenance of ultra-high-speed water spray fixed systems.

DocumentType
Standard
ISBN
978-145592773-9
Pages
80
ProductNote
THIS STANDARD IS REFERS TO : AWS A5.8/A5.8M, IEEE/ASTM SI-10,
PublisherName
National Fire Protection Association
Status
Current
Supersedes

NFPA 122:2023 Standard for Fire Prevention and Control in Metal/Nonmetal Mining and Metal Mineral Processing Facilities
NFPA 59A:2023 Standard for the Production, Storage, and Handling of Liquefied Natural Gas (LNG)
NFPA 423:2022 Standard for Competencies for EMS Personnel Responding to Hazardous Materials/Weapons of Mass Destruction Incidents
NFPA 2:2023 Hydrogen Technologies Code
NFPA 101:2024 Life Safety Code
NFPA 415:2022 Standard on Airport Terminal Buildings, Fueling Ramp Drainage, and Loading Walkways
NFPA 914:2023 Code for the Protection of Historic Structures
NFPA 45:2024 Standard on Fire Protection for Laboratories Using Chemicals
NFPA 409:2022 Standard on Aircraft Hangars
NFPA 34:2024 Standard for Dipping, Coating, and Printing Processes Using Flammable or Combustible Liquids
NFPA 18A:2022 Standard on Water Additives for Fire Control and Vapor Mitigation
NFPA 40:2025 Standard for the Storage and Handling of Cellulose Nitrate Film
NFPA 31:2024 Standard for the Installation of Oil-Burning Equipment
NFPA 25:2023 Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems
NFPA 37:2024 Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines
NFPA 30:2024 Flammable and Combustible Liquids Code
NFPA 820:2024 Standard for Fire Protection in Wastewater Treatment and Collection Facilities
PIP VEETA001:2024 Tank Selection Guide
NFPA 59:2024 Utility LP-Gas Plant Code

NFPA 22 : 2018 WATER TANKS FOR PRIVATE FIRE PROTECTION
NFPA 24 : 2019 Standard for the Installation of Private Fire Service Mains and Their Appurtenances
NFPA 20 : 2019 Standard for the Installation of Stationary Pumps for Fire Protection
NFPA 30:2021 Flammable and Combustible Liquids Code
NFPA 25 : 2020 Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems
NFPA 72:2019 National Fire Alarm and Signaling Code
NFPA 70 : 2020 National Electrical Code (NEC) Softbound
ASTM D 323 : 2015 Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method)
NFPA 13 : 2019 Standard for the Installation of Sprinkler Systems

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.