NFPA 286 : 2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH
Hardcopy
English
01-01-2015
26-08-2021
Chapter 1 - Administration
Chapter 2 - Referenced Publications
Chapter 3 - Definitions
Chapter 4 - Test Equipment
Chapter 5 - Specimen Mounting
Chapter 6 - Environmental Conditions
Chapter 7 - Instrumentation
Chapter 8 - Calibration
Chapter 9 - Test Procedure
Chapter 10 - Calculation Methods
Chapter 11 - Report
Annex A - Explanatory Material
Annex B - Method of Determining Suitability of Oxygen
Analyzers for Making Heat Release Measurements
Annex C - Acceptance Criteria
Annex D - Informational References
Index
Explains a method for determining the contribution of interior finish materials to room fire growth during specified fire exposure conditions.
| DocumentType |
Standard
|
| Pages |
31
|
| PublisherName |
National Fire Protection Association
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| ASTM E 1537 : 2016 : REDLINE | Standard Test Method for Fire Testing of Upholstered Furniture |
| NFPA 150 : 2016 | FIRE AND LIFE SAFETY IN ANIMAL HOUSING FACILITIES |
| NFPA 555 : 2017 | METHODS FOR EVALUATING POTENTIAL FOR ROOM FLASHOVER |
| NFPA 701 : 2015 | FIRE TESTS FOR FLAME PROPAGATION OF TEXTILES AND FILMS |
| NFPA 90B : 2018 | INSTALLATION OF WARM AIR HEATING AND AIR-CONDITIONING SYSTEMS |
| NFPA 255 : 2006 | TEST OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS |
| NFPA 275 : 2017 | STANDARD METHOD OF FIRE TESTS FOR THE EVALUATION OF THERMAL BARRIERS |
| NFPA 99 : 2018 | HEALTH CARE FACILITIES CODE |
| NFPA 101A : 2016 | ALTERNATIVE APPROACHES TO LIFE SAFETY |
| NFPA 259 : 2018 | STANDARD TEST METHOD FOR POTENTIAL HEAT OF BUILDING MATERIALS |
| NFPA 5000 : 2018 | BUILDING CONSTRUCTION AND SAFETY CODE |
| ICC 2009 INT. RESI.CODE & COMM.-I1 : 2009 | 2009 INTERNATIONAL RESIDENTIAL CODE & COMMENTARY - VOLUME 2: CHAPTERS 12 TO 44 |
| ASTM E 2280 : 2017 : REDLINE | Standard Guide for Fire Hazard Assessment of the Effect of Upholstered Seating Furniture Within Patient Rooms of Health Care Facilities |
| ASTM E 2957 : 2017 : REDLINE | Standard Test Method for Resistance to Wildfire Penetration of Eaves, Soffits and Other Projections |
| NFPA 90A : 2018 | INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS |
| NFPA 301 : 2018 | SAFETY TO LIFE FROM FIRE ON MERCHANT VESSELS |
| NFPA 130 : 2017 | FIXED GUIDEWAY TRANSIT AND PASSENGER RAIL SYSTEMS |
| NFPA 909 : 2017 | PROTECTION OF CULTURAL RESOURCE PROPERTIES - MUSEUMS, LIBRARIES, AND PLACES OF WORSHIP |
| ICC 2012 INTERNATIONAL BUILDING CODE : 2012 | INTERNATIONAL BUILDING CODE |
| NFPA 1 : 2021 | FIRE CODE |
| NFPA 265 : 2015 | METHODS OF FIRE TESTS FOR EVALUATING ROOM FIRE GROWTH CONTRIBUTION OF TEXTILE OR EXPANDED VINYL WALL COVERINGS ON FULL HEIGHT PANELS AND WALLS |
| FM 4880 : 2017 | EVALUATING THE FIRE PERFORMANCE OF INSULATED BUILDING PANEL ASSEMBLIES AND INTERIOR FINISH MATERIALS |
| ASTM F 1870 : 2016 : REDLINE | Standard Guide for Selection of Fire Test Methods for the Assessment of Upholstered Furnishings in Detention and Correctional Facilities |
| NFPA 101 : 2018 | LIFE SAFETY CODE |
| ISO/TR 10093:2017 | Plastics — Fire tests — Standard ignition sources |
| ICC IRC CODE AND COMMENTARY VOLUME 2 : 2015 | IRC® Code and Commentary, Volume 2 |
| ASTM F 793/F793M : 2015 : REDLINE | Standard Classification of Wall Coverings by Use Characteristics |
| ICC IBC CODE AND COMMENTARY VOLUME 2 : 2015 | IBC® Code and Commentary, Volume 2 |
| ICC 2012 INTERNATIONAL FIRE CODE : 2012 | INTERNATIONAL FIRE CODE |
| ICC IMC Code and Commentary : 2015 | IMC® Code and Commentary |
| ICC IFC CODE & COMMENTARY VOLUME 1 & 2 : 2015 | IFC® Code and Commentary |
| ASTM E 603 : 2017 : REDLINE | Standard Guide for Room Fire Experiments |
| ICC 2012 INTERNATIONAL RESI. CODE : 2012 | INTERNATIONAL RESIDENTIAL CODE FOR ONE- AND TWO-FAMILY DWELLINGS |
| ASTM E 2634 : 2017-06 | SPECIFICATION FOR FLAT WALL INSULATING CONCRETE FORM (ICF) SYSTEMS |
| ICC IRC Code and Commentary Volume 1 : 2015 | IRC® Code and Commentary, Volume 1 |
| ASTM E 2067 : 2015 : REDLINE | Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests |
| ASTM E 2257 : 2017 : REDLINE | Standard Test Method for Room Fire Test of Wall and Ceiling Materials and Assemblies |
| MIL-PRF-32514 Base Document:2015 | Insulation, Anti-Sweat, Refrigerant, and Thermal Foam |
| NFPA 289 : 2013 | STANDARD METHOD OF FIRE TEST FOR INDIVIDUAL FUEL PACKAGES |
| ASTM E 1740 : 2015 : REDLINE | Standard Test Method for Determining the Heat Release Rate and Other<brk/> Fire-Test-Response Characteristics of Wall Covering or Ceiling Covering Composites Using a Cone Calorimeter |
| NSF 342 : 2014 | SUSTAINABILITY ASSESSMENT FOR WALLCOVERING PRODUCTS |
| ASTM E 1590 : 2017 : REDLINE | Standard Test Method for Fire Testing of Mattresses |
| ASTM C 1852 : 2017 | Standard Guide for Product Selection/Delivery Systems for Aerosol Foam Sealants and Adhesives |
| NFPA 705 : 2018 | RECOMMENDED PRACTICE FOR A FIELD FLAME TEST FOR TEXTILES AND FILMS |
| ASTM E 2574/E2574M : 2017 : REDLINE | Standard Test Method for Fire Testing of School Bus Seat Assemblies |
| NFPA 1 : 2018 | FIRE CODE |
| ICC California Fire Code:2019 | 2019 California Fire Code, Title 24, Part 9 |
| ICC IMC CODE AND COMMENTARY:2021 | IMC® Code and Commentary |
| ICC IRC International Residential Code:2021 | 2021 International Residential Code |
| ICC IBC INTERNATIONAL BUILDING CODE:2021 | International Building Code |
| ASTM E 800 : 2014 : REDLINE | Standard Guide for Measurement of Gases Present or Generated During Fires |
| NFPA 101 : 2018 | LIFE SAFETY CODE |
| ASTM E 2573 : 2017 : REDLINE | Standard Practice for Specimen Preparation and Mounting of Site-Fabricated Stretch Systems to Assess Surface Burning Characteristics |
| ASTM C 1396/C1396M : 2017 : REDLINE | Standard Specification for Gypsum Board |
| ASTM E 136 : 2016-02 | TEST METHOD FOR BEHAVIOUR OF MATERIALS IN A VERTICAL TUBE FURNACE AT 750 DEGREES C |
| ICC IBC INTERNATIONAL BUILDING CODE : 2015 | INTERNATIONAL BUILDING CODE |
| NFPA 265 : 2015 | METHODS OF FIRE TESTS FOR EVALUATING ROOM FIRE GROWTH CONTRIBUTION OF TEXTILE OR EXPANDED VINYL WALL COVERINGS ON FULL HEIGHT PANELS AND WALLS |
| ICC IFC INTERNATIONAL FIRE CODE : 2015 | INTERNATIONAL FIRE CODE |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.