• Shopping Cart
    There are no items in your cart

NFPA 33:2024

Current

Current

The latest, up-to-date edition.

Standard for Spray Application Using Flammable or Combustible Materials

Available format(s)

Hardcopy

Language(s)

English

Published date

21-12-2023

€133.70
Excluding VAT

Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Application. 1.4 Retroactivity. 1.5 Equivalency. 1.6 Units and Formulas. 1.7 Enforcement. (Reserved) Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. 2.3 Other Publications. 2.4 References for Extracts in Mandatory Sections. Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. Chapter 4 General Requirements 4.1 Location of Spray Application Operations. 4.2 Separation. 4.3 Basements. 4.4 Fueled Vehicles. 4.5 Noncombustible Material. 4.6 Limited-Combustible Material. 4.7 Classification Scheme. 4.8 Determination of Flash Point (FP). Chapter 5 Construction and Design of Spray Areas, Spray Rooms, and Spray Booths 5.1 Spray Areas. 5.2 Spray Rooms.5.3 Spray Booths. 5.4 Conveyor Openings. 5.5 Separation from Other Operations. 5.6 Illumination and Observation Panels. 5.7 Ventilation. Chapter 6 Electrical and Other Sources of Ignition 6.1 Scope. 6.2 General. 6.3 Electrical Area Classification. 6.4 Electrical Devices in Spray Areas. 6.5 Electrical Devices in Areas Adjacent to or Connected to Spray Areas. 6.6 Illumination. 6.7 Static Electricity. 6.8 Flexible Power Cords. 6.9 Portable Electric Luminaires. 6.10 Movement of Powered Vehicles. Chapter 7 Ventilation 7.1 General. 7.2 Performance Requirements. 7.3 Make-Up Air. 7.4 Routing of Exhaust Ducts. 7.5 Recirculation of Exhaust. 7.6 Heating of Recirculated Air. 7.7 Manifolding of Exhaust Ducts. 7.8 Materials of Construction. 7.9 Support of Exhaust Ducts. 7.10 Exhaust Duct Access Openings. 7.11 Exhaust Fans and Drives. 7.12 Drying Areas.Chapter 8 Storage, Handling, and Distribution of Ignitible (Flammable and Combustible) Liquids 8.1 General. 8.2 Storage in Process Areas. 8.3 Handling and Use. 8.4 Distribution Systems — Piping. 8.5 Distribution Systems — General. Chapter 9 Protection 9.1 General. 9.2 Ventilation Systems. 9.3 Coating Material Delivery Systems. 9.4 Conveyors. 9.5 Protection Systems. 9.6 Specific Process Protection. 9.7 Protection for Electrostatic Precipitator Scrubber. 9.8 Protection for High-Capacity Dry Paint Arrestor. Chapter 10 Operations and Maintenance 10.1 General. 10.2 Inspection, Testing, and Maintenance. 10.3 Combustible Residues. 10.4 High-Pressure Hose Lines. 10.5 Maintenance Procedures. 10.6 Waste Containers. 10.7 Clothing. 10.8 Cleaning Operations. 10.9 Solvent Distillation Units (Solvent Recyclers). 10.10 Spontaneous Ignition Hazards. 10.11 Chlorinated Solvents. 10.12 Smoking. 10.13 Hot Work.Chapter 11 Automated Electrostatic Spray Equipment 11.1 Scope. 11.2 General. 11.3 Automated Electrostatic Systems. 11.4 Incendive Equipment. 11.5 Listing and Approval of Equipment. Chapter 12 Handheld Electrostatic Spray Equipment 12.1 Scope. 12.2 General. 12.3 Handheld Apparatus. 12.4 Electrical Components. 12.5 Grounding. Chapter 13 Drying, Curing, and Fusion Processes 13.1 General. 13.2 Spray Booths and Spray Rooms Used for Ambient Air Drying. 13.3 Spray Booths and Spray Rooms Used for Drying at Elevated Temperatures. 13.4 Liquefied-Petroleum-Gas, Compressed-Natural-Gas, or Hydrogen-Fueled Vehicles. 13.5 Radiant Drying Apparatus. 13.6 Flash-Off Areas. 13.7 Spray Booths or Spray Rooms Adjacent to or Connected to Rooms or Equipment Used for Drying, Curing, or Fusing. 13.8 Ventilation. 13.9 Warning Signs. Chapter 14 Miscellaneous Spray Operations 14.1 Vehicle Undercoating and Body Lining. 14.2 Preparation Workstations. 14.3 Limited Finishing Workstations. 14.4 Inflatable Finishing Workstations. Chapter 15 Powder Coating 15.1 Scope.15.2 General. 15.3 Applicability. 15.4 Location. 15.5 Construction and Design of Spray Booths and Spray Rooms. 15.6 Electrical and Other Sources of Ignition. 15.7 Ventilation and Dust Collection. 15.8 Storage and Handling. 15.9 Protection. 15.10 Operation and Maintenance. 15.11 Automated Electrostatic Powder Spraying Equipment. 15.12 Handheld Electrostatic Powder Spraying Equipment. 15.13 Drying, Curing, and Fusing Equipment. 15.14 Electrostatic Fluid Beds. 15.15 Hot Flocking. 15.16 Fluid Bed Coating. Chapter 16 Organic Peroxides and Plural Component Coatings 16.1 Scope. 16.2 General. 16.3 Prevention of Contamination. 16.4 Storage of Organic Peroxides. 16.5 Handling of Organic Peroxides. 16.6 Mixing of Organic Peroxides with Promoters. 16.7 Smoking. 16.8 Trained Personnel. 16.9 Material Safety Data Sheets. Chapter 17 Styrene Cross-Linked Composites Manufacturing (Glass Fiber–Reinforced Plastics) 17.1 Scope. 17.2 Resin Application Equipment. 17.3 Fire Protection.17.4 Resin Storage. 17.5 Electrical and Other Hazards. 17.6 Ventilation. 17.7 Use and Handling. Chapter 18 Spray Application Operations in Membrane Enclosures 18.1 Scope. 18.2 Limitations. 18.3 Membrane Material. 18.4 Protection. 18.5 Personnel Inside the Enclosure. 18.6 Electrical and Other Sources of Ignition. 18.7 Ventilation. 18.8 Recordkeeping. 18.9 Storage and Handling of Ignitible (Flammable and Combustible) Liquids. 18.10 Facilities Compliance Permitting. Chapter 19 Training 19.1 General. Annex A Explanatory Material Annex B Determining Lower Flammable Limits Annex C Determining Ventilation Airflow for Powder Application Systems Annex D Fire Record Annex E Informational References

1.1.1* This standard shall apply to the spray application of flammable or combustible materials, as herein defined, either continuously or intermittently by any of the following methods: (1) Compressed air atomization (2) Airless or hydraulic atomization (3) Electrostatic application methods (4) Other means of atomized application 1.1.2 This standard shall also apply to the application of flam‐ mable or combustible materials, as herein defined, either continuously or intermittently by any of the following methods: (1) Fluidized bed application methods (2) Electrostatic fluidized bed application methods (3) Other means of fluidized application 1.1.3 This standard shall also apply to the spray application of water-borne, water-based, and water-reducible materials that contain ignitible (flammable or combustible) liquids or that produce combustible deposits or residues.

DocumentType
Standard
Pages
70
PublisherName
National Fire Protection Association
Status
Current
Supersedes

NFPA 13:2025 Standard for the Installation of Sprinkler Systems

NFPA 400:2022 Hazardous Materials Code
NFPA 5000:2024 Building Construction and Safety Code
NFPA 11:2024 Standard for Low-, Medium, and High-Expansion Foam
NFPA 496:2024 Standard for Purged and Pressurized Enclosures for Electrical Equipment
NFPA 701:2023 Standard Methods of Fire Tests for Flame Propagation of Textiles and Films
NFPA 30:2021 Flammable and Combustible Liquids Code
NFPA 10 : 2018 PORTABLE FIRE EXTINGUISHERS
NFPA 12 : 2018 CARBON DIOXIDE EXTINGUISHING SYSTEMS
NFPA 86 : 2019 Standard for Ovens and Furnaces<br>
NFPA 289:2023 Standard Method of Fire Test for Individual Fuel Packages
NFPA 750:2023 Standard on Water Mist Fire Protection Systems
NFPA 72:2019 National Fire Alarm and Signaling Code
NFPA 770:2021 Standard on Hybrid (Water and Inert Gas) Fire Extinguishing Systems
NFPA 70 : 2020 National Electrical Code (NEC) Softbound
NFPA 2001:2022 Standard on Clean Agent Fire Extinguishing Systems
NFPA 13 : 2019 Standard for the Installation of Sprinkler Systems
NFPA 69 : 2019 Standard on Explosion Prevention Systems
NFPA 91:2020 Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.