Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Application. (Reserved) 1.4 Retroactivity. 1.5 Equivalency. 1.6 Units and Formulas. 1.7 Code Adoption Requirements. (Reserved) Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. 2.3 Other Publications. 2.4 References for Extracts in Mandatory Sections. Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. 3.4 Classification of Liquids. Chapter 4 Location of Plants and Buildings 4.1 Location. 4.2 General Layout and Design. Chapter 5 Building Construction 5.1 General Construction. 5.2 Drainage. 5.3 Building Heating. 5.4 Ventilation. 5.5 Deflagration (Explosion) Venting. 5.6 Electrical Equipment. Chapter 6 Process Equipment and Operations 6.1 Transfer of Flammable and Combustible Liquids. 6.2 Piping, Valves, and Fittings. 6.3 Kettles, Reactors, and Vessels. 6.4 Dispersion Equipment. 6.5 Ball Mills and Pebble Mills. 6.6 Mixers and Mixing Tanks. Chapter 7 Material Storage and Handling 7.1 Tank Car and Tank Vehicle Unloading and Loading. 7.2 Flammable and Combustible Liquid Storage. 7.3 Storage of Finished Products. 7.4 Outdoor Storage. 7.5 In-Plant Transportation and Storage of Portable Shipping Tanks. 7.6 Power-Operated Industrial Trucks. Chapter 8 Special Hazards 8.1 Nitrocellulose. 8.2 Monomers. 8.3 Organic Peroxide Formulations. Chapter 9 Control of Ignition Sources 9.1 Ignition Sources. 9.2 Smoking. 9.3 Hot Work. 9.4 Repair of Electrical Equipment. 9.5 Static Electricity Hazards. 9.6 Lightning Protection. Chapter 10 Management of Fire Hazards 10.1 Scope. 10.2 Basic Requirements. 10.3 Evaluation of Hazards. 10.4 Emergency Action Plans. 10.5 Management of Change. 10.6 Fire Investigation. Chapter 11 Fire Protection 11.1 Scope. 11.2 Automatic Sprinkler Protection. 11.3 Fire Hydrants. 11.4 Emergency Notification. 11.5 Portable Fire Extinguishers. 11.6 Standpipe and Hose Systems. 11.7 Hose Connections. 11.8 Fixed Local Application Extinguishing Systems. Chapter 12 Training and Emergency Planning 12.1 Basic Training Requirements. 12.2 Emergency Planning. Chapter 13 Inspection and Maintenance 13.1 General. 13.2 Confined Space Entry. 13.3 Cleaning Tanks and Vessels. 13.4 Floor Cleaning. Annex A Explanatory Material Annex B Operational Practices Annex C Informational References
This standard shall apply to facilities that use flammable and combustible liquids, as herein defined, to manufacture organic coatings for automotive, industrial, institutional, household, marine, printing, transportation, and other applications.
DocumentType |
Standard
|
Pages |
38
|
ProductNote |
This standard is also refers to ASTM D5:2013,Title 29, Code of Federal Regulations, Part 1910.146,Title 29, Code of Federal Regulations, Part 1910.147.
|
PublisherName |
National Fire Protection Association
|
Status |
Current
|
Supersedes |
NFPA 30:2024 | Flammable and Combustible Liquids Code |
UL 9:8ED 2009-07-02 | Standard for Fire Tests of Window Assemblies |
ASTM D 86 : 2018 | Standard Test Method for Distillation of Petroleum Products and Liquid Fuels at Atmospheric Pressure |
NFPA 400 : 2019 | Hazardous Materials Code |
NFPA 505 : 2018 | FIRE SAFETY STANDARD FOR POWERED INDUSTRIAL TRUCKS INCLUDING TYPE DESIGNATIONS, AREAS OF USE, CONVERSIONS, MAINTENANCE, AND OPERATIONS |
ASTM D 92 : 2018 | Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester |
NFPA 24 : 2019 | Standard for the Installation of Private Fire Service Mains and Their Appurtenances |
NFPA 16 : 2019 | Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems |
UL 10B:10ED 2008-02-07 | Standard for Fire Tests of Door Assemblies |
NFPA 30:2021 | Flammable and Combustible Liquids Code |
NFPA 15 : 2017 | WATER SPRAY FIXED SYSTEMS FOR FIRE PROTECTION |
NFPA 10 : 2018 | PORTABLE FIRE EXTINGUISHERS |
NFPA 326 : 2020 | Standard for the Safeguarding of Tanks and Containers for Entry, Cleaning, or Repair |
NFPA 221:2021 | Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls |
NFPA 11 : 2016 | LOW-, MEDIUM-, AND HIGH-EXPANSION FOAM |
NFPA 25 : 2020 | Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems |
NFPA 14 : 2019 | Standard for the Installation of Standpipe and Hose Systems |
NFPA 257 : 2017 | FIRE TEST FOR WINDOW AND GLASS BLOCK ASSEMBLIES |
NFPA 70 : 2020 | National Electrical Code (NEC) Softbound |
NFPA 496:2021 | Standard for Purged and Pressurized Enclosures for Electrical Equipment |
NFPA 13 : 2019 | Standard for the Installation of Sprinkler Systems |
ASTM D 323 : 2015 : REV A | Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method) |
NFPA 101:2021 | Life Safety Code |
NFPA 252 : 2017 | STANDARD METHODS OF FIRE TESTS OF DOOR ASSEMBLIES |