NFPA 557 : 2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
DETERMINATION OF FIRE LOAD FOR USE IN STRUCTURAL FIRE PROTECTION DESIGN
Hardcopy
16-07-2019
English
01-01-2016
Chapter 1 - Administration
Chapter 2 - Referenced Publications
Chapter 3 - Definitions
Chapter 4 - Design Fundamentals
Chapter 5 - Development of Fire Loads
Chapter 6 - Occupancy-Based Fire Load
Density
Chapter 7 - Survey Method-Based Fire Load
Density
Chapter 8 - Documentation, Inspection, and
Maintenance
Annex A - Explanatory Material
Annex B - Summary of Occupancy Based Fuel
and Fire Load Survey Data
Annex C - Guidance for Fuel or Fire Load Surveys
(Special Facility and Occupancy Based)
Annex D - Analyses of Structurally Significant
Fires in Buildings with Selected
Characteristics
Annex E - Informational References
Index
Gives standard methods and values for use in the determination of fire loads and fire load densities for design-basis fires, which is done using a risk framework.
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
National Fire Protection Association
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
NFPA 914 : 2015 | FIRE PROTECTION OF HISTORIC STRUCTURES |
ICC ICCPC INTERNATIONAL PERFORMANCE CODE : 2015 | ICC PERFORMANCE CODE FOR BUILDINGS AND FACILITIES |
ASTM E 1537 : 2016 : REDLINE | Standard Test Method for Fire Testing of Upholstered Furniture |
NFPA 262 : 2015 | METHOD OF TEST FOR FLAME TRAVEL AND SMOKE OF WIRES AND CABLES FOR USE IN AIR-HANDLING SPACES |
NFPA 259 : 2013 | STANDARD TEST METHOD FOR POTENTIAL HEAT OF BUILDING MATERIALS |
UL 1820:4ED 2004-10-15 | Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics |
NFPA 101 : 2018 | LIFE SAFETY CODE |
NFPA 400 : 2016 | HAZARDOUS MATERIALS CODE |
NFPA 90A : 2018 | INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS |
UL 2024:5ED 2014-03-25 | Cable Routing Assemblies and Communications Raceways |
ASTM E 136 : 2016-02 | TEST METHOD FOR BEHAVIOUR OF MATERIALS IN A VERTICAL TUBE FURNACE AT 750 DEGREES C |
ASCE 7 10 : 2010 | MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
UL 1666:5ED 2007-02-16 | Test for Flame Propagation Height of Electrical and Optical-Fiber Cables Installed Vertically in Shafts |
NFPA 555 : 2017 | METHODS FOR EVALUATING POTENTIAL FOR ROOM FLASHOVER |
ASTM E 1590 : 2017 : REDLINE | Standard Test Method for Fire Testing of Mattresses |
ASTM E 2768 : 2011 | Standard Test Method for Extended Duration Surface Burning Characteristics of Building Materials (30 min Tunnel Test) |
UL 1887:3ED 2004-10-15 | Fire Test of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.