    Table of Contents - (Show below) - (Hide below)

    Chapter 1 Introduction
    1.1 Scope
    1.2 Purpose
    Chapter 2 General
    2.1 Furnace explosions
    2.2 Manufacture, design, and engineering
    2.3 Installation
    2.4 Coordination of design, construction, and operation
    2.5 Maintenance organization
    2.6 Basic operating objectives
    2.7 Gas and oil firing - special problems
    Chapter 3 Definitions
    Chapter 4 Equipment requirements
    4.1 Fuel supply (oil)
    4.2 Fuel supply (gas)
    4.3 Alternate fuel firing
    4.4 Fuel burning equipment
    4.5 Burner management system, logic
    4.6 Combustion control system
    4.7 Interlock system
    4.8 Flame safety shutdown system
    4.9 Electrical equipment
    Chapter 5 Starting a cold boiler
    5.1 General
    5.2 Gas-fired boilers
    5.3 Oil-fired burners
    Chapter 6 Operating systems
    6.1 General
    6.2 Automatic (recycling) systems for watertube boilers
    6.3 Automatic (nonrecycling) systems for watertube
         boilers
    6.4 Automatic (recycling) systems for firetube boilers
    6.5 Automatic (nonrecycling) systems for firetube
         boilers
    6.6 Supervised manual systems for oil-fired watertube
         boilers
    6.7 Supervised manual systems for gas-fired watertube
         boilers
    6.8 Soot blowing
    Chapter 7 Simultaneous firing of oil and gas fuels
    7.1 General
    7.2 Continuous firing
    7.3 Light-off cycles
    7.4 Normal shutdown procedure
    Chapter 8 Simultaneous firing of oil and gas for fuel
                transfer only
    8.1 Transfer without shutdown
    8.2 Simultaneous firing on a continuous basis
    8.3 Single fuel firing without airflow biasing
    8.4 Single fuel firing with airflow biasing
    Chapter 9 Dual oil atomizers in a single burner
    9.1 General
    9.2 Changeover procedures
    Chapter 10 Inspection and maintenance
    10.1 General
    10.2 Inspection and maintenance schedule
    10.3 Familiarity with equipment and procedures
    Chapter 11 Referenced publications
    Appendix A
    Appendix B Referenced publications
    Index

    Abstract - (Show below) - (Hide below)

    Applies to boilers with fuel input greater than 12,500,000 btu/hr (3663 Kw) or greater. This standard applies only to boilers using single burners. This standard establishes minimum requirements for the design, installation, operation and maintenance of single burner boilers, their fuel-burning systems, and related systems to contribute to safe operation and, in particular, to the prevention of furnace explosions.

    General Product Information - (Show below) - (Hide below)

    Development Note Formerly NFPA 85A
    Document Type Standard
    Publisher National Fire Protection Association
    Status Withdrawn
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    F-B-2910 Base Document:1998 BURNERS, SINGLE: OIL, GAS, AND GAS-OIL COMBINATION FOR PACKAGED BOILERS (320,001 TO 125, 000,000 BTU/HR THERMAL OUTPUT CAPACITY)
    NFPA 803 : 1998 FIRE PROTECTION FOR LIGHT WATER NUCLEAR POWER PLANTS
    NFPA 8506 : 1998 HEAT RECOVERY STEAM GENERATOR SYSTEMS
    F-B-2903 Base Document:1998 BOILERS, STEAM AND HOT WATER, FIRETUBE, SCOTCH PACKAGED TYPE (320,001 TO 35,000,000 BTU/HR THERMAL OUTPUT CAPACITY)
    ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION
    UFC 3-430-11 : 2001 UNIFIED FACILITIES CRITERIA - BOILER CONTROL SYSTEMS
    ICC 2012 INTERNATIONAL MECH. CODE : 2012 INTERNATIONAL MECHANICAL CODE

    Standards Referencing This Book - (Show below) - (Hide below)

    API 500 : 2012 RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2
    NFPA 31 : 2016 INSTALLATION OF OIL-BURNING EQUIPMENT
    NFPA 58 : 2017 LIQUEFIED PETROLEUM GAS CODE
    API 2003 : 2015 PROTECTION AGAINST IGNITIONS ARISING OUT OF STATIC, LIGHTNING, AND STRAY CURRENTS
    NFPA 51B : 2014 FIRE PREVENTION DURING WELDING, CUTTING, AND OTHER HOT WORK
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    NFPA 51 : 2018 DESIGN AND INSTALLATION OF OXYGEN-FUEL GAS SYSTEMS FOR WELDING, CUTTING, AND ALLIED PROCESSES
    NFPA 30 : 2018 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE
    NFPA 77 : 2014 STATIC ELECTRICITY
    NFPA 54 : 2018 NATIONAL FUEL GAS CODE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective