NFPA 92 : 2018
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SMOKE CONTROL SYSTEMS
Hardcopy
English
01-01-2018
16-08-2021
Chapter 1 - Administration
Chapter 2 - Referenced Publications
Chapter 3 - Definitions
Chapter 4 - Design Fundamentals
Chapter 5 - Smoke Management Calculation
Procedures
Chapter 6 - Building Equipment and Controls
Chapter 7 - Smoke Control System Documentation
Chapter 8 - Testing
Annex A - Explanatory Material
Annex B - Predicting the Rate of Heat Release of
Fires
Annex C - Computer-Based Models for Atria and
Malls
Annex D - Additional Design Objectives
Annex E - Stratification of Smoke
Annex F - Types of Stairwell Pressurization Systems
Annex G - HVAC Air-Handling System Types
Annex H - Fire Fighters Smoke Control Station (FSCS)
Considerations
Annex I - Information on Testing for Leakage
Between Smoke Zones
Annex J - Advisory Information on Acceptance
Testing
Annex K - Example Problems Illustrating the Use of
Equations
Annex L - Comparison of Equations
Annex M - Tenability
Annex N - Informational References
Index
Pertains to the design, installation, acceptance testing, operation, and ongoing periodic testing of smoke control systems.
| DevelopmentNote |
Supersedes NFPA 92A and NFPA 92B. (12/2011)
|
| DocumentType |
Standard
|
| Pages |
94
|
| PublisherName |
National Fire Protection Association
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| ICC IMC International Mechanical Code : 2021 | International Mechanical Code |
| ICC IBC INTERNATIONAL BUILDING CODE:2021 | International Building Code |
| NFPA 850:2020 | Recommended Practice for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations |
| NFPA 555:2021 | Guide on Methods for Evaluating Potential for Room Flashover |
| UL 555:7ED 2006-07-12 | Fire Dampers |
| NFPA 556 : 2016 | GUIDE ON METHODS FOR EVALUATING FIRE HAZARD TO OCCUPANTS OF PASSENGER ROAD VEHICLES |
| NFPA 909 : 2017 | PROTECTION OF CULTURAL RESOURCE PROPERTIES - MUSEUMS, LIBRARIES, AND PLACES OF WORSHIP |
| ISO 21927-9:2012 | Smoke and heat control systems — Part 9: Specification for control equipment |
| UL 864:10ED 2014-12-01 | Standard for Control Units and Accessories for Fire Alarm Systems |
| NFPA 110 : 2016 | EMERGENCY AND STANDBY POWER SYSTEMS |
| ISO 21927-1:2008 | Smoke and heat control systems — Part 1: Specification for smoke barriers |
| NFPA 101 : 2018 | LIFE SAFETY CODE |
| NFPA 221 : 2018 | HIGH CHALLENGE FIRE WALLS, FIRE WALLS, AND FIRE BARRIER WALLS |
| NFPA 90A : 2018 | INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS |
| NFPA 5000 : 2018 | BUILDING CONSTRUCTION AND SAFETY CODE |
| NFPA 3 : 2018 | COMMISSIONING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS |
| ISO 21927-10:2011 | Smoke and heat control systems — Part 10: Specification for power output devices |
| NFPA SFPE PERFORMANCE BASED FIRE PROT : 2006 | SFPE ENGINEERING GUIDE TO PERFORMANCE-BASED FIRE PROTECTION |
| ASHRAE HDBK SMOKE CONTROL ENGINEERING : 2012 | HANDBOOK OF SMOKE CONTROL ENGINEERING |
| ISO 21927-7:2017 | Smoke and heat control systems — Part 7: Smoke ducts sections |
| NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
| NFPA 1 : 2018 | FIRE CODE |
| BS EN 12101-1 : 2006 | SMOKE AND HEAT CONTROL SYSTEMS - PART 1: SPECIFICATION FOR SMOKE BARRIERS |
| NFPA 72 : 2016 | NATIONAL FIRE ALARM AND SIGNALING CODE |
| NFPA 13 : 2016 | INSTALLATION OF SPRINKLER SYSTEMS |
| ISO 21927-3:2006 | Smoke and heat control systems — Part 3: Specification for powered smoke and heat exhaust ventilators |
| NFPA 269 : 2017 | TEST METHOD FOR DEVELOPING TOXIC POTENCY DATA FOR USE IN FIRE HAZARD MODELING |
| ISO 21927-2:2006 | Smoke and heat control systems — Part 2: Specification for natural smoke and heat exhaust ventilators |
| NFPA 204 : 2015 | SMOKE AND HEAT VENTING |
| ASME A17.1 : 2016 | SAFETY CODE FOR ELEVATORS AND ESCALATORS - INCLUDES REQUIREMENTS FOR ELEVATORS, ESCALATORS, DUMBWAITERS, MOVING WALKS, MATERIAL LIFTS, AND DUMBWAITERS WITH AUTOMATIC TRANSFER DEVICES |
| NFPA 80 : 2016 | FIRE DOORS AND OTHER OPENING PROTECTIVES |
| ASTM E 1354 : 2017 : REDLINE | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.