ONORM EN 13725 : 2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
AIR QUALITY - DETERMINATION OF ODOUR CONCENTRATION BY DYNAMIC OLFACTOMETRY
08-09-2022
12-01-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Principle of measurement
5 Performance quality requirements
6 Materials, gases and panel members
7 Sampling
8 Presentation of odorants to assessors
9 Data recording, calculation and reporting
Annex A (normative) Working conditions and working platform
for sampling
Annex B (informative) Physiological principles
Annex C (informative) Example of calculation of instrumental
accuracy and instability
Annex D (informative) Example of calculation of odour
measurements within one laboratory
Annex E (informative) Example of calculation for panel
selection
Annex F (informative) Example of the calculation of the odour
concentration from a set of panel member responses
Annex G (informative) Example of the calculation used to
determine the number of odour concentration
measurements required to achieve a defined precision
Annex H (informative) Example of the calculation used to
determine the number of odour concentration
measurements required to detect a difference between
two means
Annex I (informative) Example of the calculation of the odour
flow rate (standard conditions) for a wet emission
Annex J (informative) Sampling strategy
Bibliography
Describes method for the objective determination of the odour concentration of a gaseous sample using dynamic olfactometry with human accessories and the emission rate of odours emanating from point success, areas sources with outward flow and area sources without outward flow.
Committee |
TC 139
|
DocumentType |
Standard
|
PublisherName |
Osterreichisches Normungsinstitut/Austrian Standards
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
UNE-EN 13725:2004 | Identical |
DIN EN 13725:2003-07 | Identical |
I.S. EN 13725:2003 | Identical |
UNI EN 13725 : 2004 | Identical |
NBN EN 13725 : 2003 COR 2006 | Identical |
NEN EN 13725 : 2003 C1 2006 | Identical |
NS EN 13725 : 2003 AC 2006 | Identical |
SN EN 13725 : 2003 CORR 2006 | Identical |
NF EN 13725 : 2003 | Identical |
ISO 10780:1994 | Stationary source emissions — Measurement of velocity and volume flowrate of gas streams in ducts |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.